Dual-energy spectral CT imaging of pulmonary embolism with Mycoplasma pneumoniae pneumonia in children

Author(s):  
Lixin Yang ◽  
Jihang Sun ◽  
Jianying Li ◽  
Yun Peng
2020 ◽  
Author(s):  
Lixin Yang ◽  
Jihang Sun ◽  
Jiangying Li ◽  
Tong Yu ◽  
Bei Wang ◽  
...  

Abstract Background: Pulmonary embolism (PE) associated with Mycoplasma pneumoniae pneumonia (MPP) in children has already attracted more attention. We aimed to evaluate the application of dual-energy spectral CT in diagnosing PE in children with MPP.Methods: Eight-three children with MPP and highly suspected PE, underwent CT pulmonary angiography (CTPA) with spectral imaging mode. Noise, clot-to-artery contrast-to-noise ratio, image quality and diagnosis confidence were calculated and assessed on nine monochromatic image sets (40 to 80keV). CTPA images were observed for the presence, localization, and embolic degrees of PE. Emboli were divided between intra and extra-consolidation. For extra-consolidation clots, iodine concentration (IC) of perfusion defects and normal lung, perfusion defects of 4 children before and after the treatment were measured and compared. For intra-consolidation clots, IC of consolidation areas with clots and consolidation areas without clot were measured and compared.Results: The optimal energy level for detecting PE in children was 55 keV. 116 clots (29 extra consolidations) were found in 25 children, IC of defect regions associated with PE was 0.69±0.28mg/mL (extra-consolidations) and 0.90±0.23mg/mL (intra-consolidations), both significantly lower than the 2.76±0.45mg/mL in normal lungs and 10.25±1.76mg/mL in consolidations without clots (P<0.001). Significant difference was found in the presence or absence of perfusion defects between occlusive clots and nonocclusive clots(P<0.001). IC of the perfusion defects significantly increased after treatment (P<0.001).Conclusions: In spectral CTPA 55 keV images optimize PE detection for children. and MD images quantify pulmonary blood flow of PE, and may help to detect small clots and quantify embolic degrees.


2017 ◽  
Vol 95 ◽  
pp. 222-227 ◽  
Author(s):  
Chuang-bo Yang ◽  
Shuang Zhang ◽  
Yong-jun Jia ◽  
Yong Yu ◽  
Hai-feng Duan ◽  
...  

2012 ◽  
Vol 81 (10) ◽  
pp. 2487-2494 ◽  
Author(s):  
Xiao Zhu Lin ◽  
Zhi Yuan Wu ◽  
Ran Tao ◽  
Yan Guo ◽  
Jian Ying Li ◽  
...  

2020 ◽  
Vol 28 (2) ◽  
pp. 345-356
Author(s):  
Xiaohu Li ◽  
Zhijie Li ◽  
Jianying Li ◽  
Jian Song ◽  
Yongqiang Yu ◽  
...  

2020 ◽  
Vol 128 ◽  
pp. 109061
Author(s):  
Xiaoqian Jia ◽  
Xianjun Li ◽  
Jianying Li ◽  
Qian Tian ◽  
Yue Yao ◽  
...  

Author(s):  
Yidi Yao ◽  
Liang Li ◽  
Zhiqiang Chen

Abstract Multi-energy spectral CT has a broader range of applications with the recent development of photon-counting detectors. However, the photons counted in each energy bin decrease when the number of energy bins increases, which causes a higher statistical noise level of the CT image. In this work, we propose a novel iterative dynamic dual-energy CT algorithm to reduce the statistical noise. In the proposed algorithm, the multi-energy projections are estimated from the dynamic dual-energy CT data during the iterative process. The proposed algorithm is verified on sufficient numerical simulations and a laboratory two-energy-threshold PCD system. By applying the same reconstruction algorithm, the dynamic dual-energy CT's final reconstruction results have a much lower statistical noise level than the conventional multi-energy CT. Moreover, based on the analysis of the simulation results, we explain why the dynamic dual-energy CT has a lower statistical noise level than the conventional multi-energy CT. The reason is that: the statistical noise level of multi-energy projection estimated with the proposed algorithm is much lower than that of the conventional multi-energy CT, which leads to less statistical noise of the dynamic dual-energy CT imaging.


Sign in / Sign up

Export Citation Format

Share Document