scholarly journals Exergoeconomic Analysis of a Novel Hybrid System by Integrating the Kalina and Heat Pump Cycles with a Nitrogen Closed Brayton System

2021 ◽  
Vol 7 ◽  
pp. 546-564
Author(s):  
Alireza Pirmohamadi ◽  
Hadi Ghaebi ◽  
Behrooz M. Ziapour ◽  
Mohammad Ebadollahi
Energies ◽  
2021 ◽  
Vol 14 (12) ◽  
pp. 3511
Author(s):  
Ali Khalid Shaker Al-Sayyab ◽  
Joaquín Navarro-Esbrí ◽  
Victor Manuel Soto-Francés ◽  
Adrián Mota-Babiloni

This work focused on a compound PV/T waste heat driven ejector-heat pump system for simultaneous data centre cooling and waste heat recovery for district heating. The system uses PV/T waste heat as the generator’s heat source, acting with the vapour generated in an evaporative condenser as the ejector drive force. Conventional and advanced exergy and advanced exergoeconomic analyses are used to determine the cause and avoidable degree of the components’ exergy destruction rate and cost rates. Regarding the conventional exergy analysis for the whole system, the compressor represents the largest exergy destruction source of 26%. On the other hand, the generator shows the lowest sources (2%). The advanced exergy analysis indicates that 59.4% of the whole system thermodynamical inefficiencies can be avoided by further design optimisation. The compressor has the highest contribution to the destruction in the avoidable exergy destruction rate (21%), followed by the ejector (18%) and condenser (8%). Moreover, the advanced exergoeconomic results prove that 51% of the system costs are unavoidable. In system components cost comparison, the highest cost comes from the condenser, 30%. In the same context, the ejector has the lowest exergoeconomic factor, and it should be getting more attention to reduce the irreversibility by design improving. On the contrary, the evaporator has the highest exergoeconomic factor (94%).


Water ◽  
2020 ◽  
Vol 12 (8) ◽  
pp. 2264
Author(s):  
Ahmed E. Tourab ◽  
Ana María Blanco-Marigorta ◽  
Aly M. Elharidi ◽  
María José Suárez-López

In this paper, an experimental and theoretical investigation is performed on a novel water desalination system based on a humidification–dehumidification technique using a heat pump. An ultrasonic water atomizer is used in the humidification process in order to improve the humidification system. In addition to that, a new configuration is employed in the humidification process (hybrid atomization system), which combines the traditional spraying atomization system and the ultrasonic water atomizer. The new humidification system performance is investigated and compared with the spraying water atomizer system in terms of humidification effectiveness and freshwater productivity. The results show that the ultrasonic water atomizer has enhanced and improved humidification effectiveness, and consequently, the productivity of freshwater. The maximum humidification effectiveness and productivity achieved by the ultrasonic water atomizer are 94.9% and 4.9 kg/h, respectively, meaning an increase of 25.2% and 18.8%, compared to the traditional spraying atomization system. The hybrid system increases humidification effectiveness and productivity by 3.8% and 8.2%, respectively, in comparison with the stand-alone ultrasonic water atomizer. A cost analysis was also carried out in this paper in order to perform an economic comparison of different humidification processes (spraying, ultrasonic; and hybrid atomization systems). The minimum production cost of one liter of freshwater amounts to $0.0311 with the spraying system, $0.0251 with the ultrasonic system, and $0.0250 with the hybrid atomization system. These results reveal the profitability of the new configuration.


Author(s):  
Danut Tokar ◽  
Catalin Stroita ◽  
Adriana Tokar ◽  
Alexandra Rusen

2016 ◽  
Vol 2016 ◽  
pp. 1-13 ◽  
Author(s):  
Yasser Abbasi ◽  
Ehsan Baniasadi ◽  
Hossein Ahmadikia

This paper investigates the performance of a ground source heat pump that is coupled with a photovoltaic system to provide cooling and heating demands of a zero-energy residential building. Exergy and sustainability analyses have been conducted to evaluate the exergy destruction rate and SI of different compartments of the hybrid system. The effects of monthly thermal load variations on the performance of the hybrid system are investigated. The hybrid system consists of a vertical ground source heat exchanger, rooftop photovoltaic panels, and a heat pump cycle. Exergetic efficiency of the solar-geothermal heat pump system does not exceed 10 percent, and most exergy destruction takes place in photovoltaic panel, condenser, and evaporator. Although SI of PV system remains constant during a year, SI of GSHP varies depending on cooling and heating mode. The results also show that utilization of this hybrid system can reduce CO2emissions by almost 70 tons per year.


2010 ◽  
Vol 28 (12) ◽  
pp. 1385-1395 ◽  
Author(s):  
Arif Hepbasli ◽  
Neslihan Colak ◽  
Ebru Hancioglu ◽  
Filiz Icier ◽  
Zafer Erbay