scholarly journals MP06-18 THE INFLUENCE OF ULTRASOUND PULSING PARAMETERS ON STONE FRAGMENTATION DURING BURST WAVE LITHOTRIPSY: A BENCHTOP STUDY

2021 ◽  
Vol 206 (Supplement 3) ◽  
Author(s):  
Ga Won Kim ◽  
Christopher Hunter ◽  
Adam Maxwell ◽  
Bryan Cunitz ◽  
Wayne Kreider
Keyword(s):  
2021 ◽  
Vol 10 (13) ◽  
pp. 2742
Author(s):  
Amelia Pietropaolo ◽  
Thomas Hughes ◽  
Mriganka Mani ◽  
Bhaskar Somani

Background: For ureteroscopy and laser stone fragmentation (URSL), the use of laser technology has shifted from low power to higher power lasers and the addition of Moses technology, that allows for ‘fragmentation, dusting and pop-dusting’ of stones. We wanted to compare the outcomes of URSL for Moses technology 60 W laser system versus matched regular Holmium 20 W laser cases. Methods: Prospective data were collected for patients who underwent URSL using a Moses 60 W laser (Group A) and matched to historical control data using a regular Holmium 20 W laser (Group B), performed by a single surgeon. Data were collected for patient demographics, stone location, size, pre- and post-operative stent, operative time, length of stay, complications and stone free rate (SFR). Results: A total of 38 patients in each group underwent the URSL procedure. The stones were matched for their location (17 renal and 11 ureteric stones). The mean single and cumulative stone sizes (mm) were 10.9 ± 4.4 and 15.5 ± 9.9, and 11.8 ± 4.0 and 16.5 ± 11.3 for groups A and B, respectively. The mean operative time (min) was 51.6 ± 17.1 and 82.1 ± 27.0 (p ≤ 0.0001) for groups A and B. The initial SFR was 97.3% and 81.6% for groups A and B, respectively (p = 0.05), with 1 and 7 patients in each group needing a second procedure (p = 0.05), for a final SFR of 100% and 97.3%. While there were 2 and 5 Clavien I/II complications for groups A and B, none of the patients in group A had any infection related complication. Conclusions: Use of Moses technology with higher power was significantly faster for stone lithotripsy and reduced operative time and the number of patients who needed a second procedure to achieve a stone free status. It seems that the use of Moses technology with a mid-power laser is likely to set a new benchmark for treating complex stones, without the need for secondary procedures in most patients.


2011 ◽  
Vol 185 (4S) ◽  
Author(s):  
Daniel Z. Yong ◽  
Michael E. Lipkin ◽  
John G. Mancini ◽  
W. Neal Simmons ◽  
Agnes J. Wang ◽  
...  

Urolithiasis ◽  
2019 ◽  
Vol 48 (4) ◽  
pp. 369-375
Author(s):  
Christopher S. Han ◽  
Joel M. Vetter ◽  
Robert Endicott ◽  
Michael Chevinsky ◽  
Affan Zafar ◽  
...  

Endoscopy ◽  
2020 ◽  
Author(s):  
Thomas R. McCarty ◽  
Rishabh Gulati ◽  
Tarun Rustagi

Abstract Background Peroral cholangioscopy with intraductal lithotripsy facilitates optically guided stone fragmentation of difficult biliary stones refractory to conventional endoscopic therapy. The aim of this study was to evaluate the efficacy and safety of peroral cholangioscopy with intraductal lithotripsy for difficult biliary stones. Methods Searches of PubMed, EMBASE, Web of Science, and Cochrane databases were performed in accordance with PRISMA and MOOSE guidelines. Measured outcomes included overall fragmentation success, single-session fragmentation and duct clearance, and rate of adverse events. Sensitivity and subgroup analyses were performed based upon cholangioscopy technique and type of lithotripsy (laser versus electrohydraulic). Heterogeneity was assessed with I 2 statistics. Publication bias was ascertained by funnel plot and Egger regression testing. Results 35 studies were included with 1762 participants (43.4 % men; mean age 61.5 [standard deviation (SD) 11.0]). Prior cholecystectomy had been performed in 37 % of patients, with a mean number of 1.6 (SD 0.5) ERCPs performed prior to lithotripsy. Mean stone size was 1.8 (SD 0.3) cm. Peroral cholangioscopy with intraductal lithotripsy achieved an overall stone fragmentation success of 91.2 % (95 %CI 88.1 % – 93.6 %; I 2 = 63.2 %) with an average of 1.3 [SD 0.6] lithotripsy sessions performed. Complete single-session fragmentation success was 76.9 % (95 %CI 71.6 % – 81.4 %; I 2 = 74.3 %). The adverse events rate was 8.9 % (95 %CI 6.5 % – 12.2 %; I 2 = 60.6 %). Mean procedure time for peroral cholangioscopy was 67.1 (SD 21.4) minutes. There was no difference in overall fragmentation rate or adverse events; however, laser lithotripsy was associated with a higher single-session fragmentation rate and shorter procedure time compared with electrohydraulic lithotripsy. Conclusions Peroral cholangioscopy with intraductal lithotripsy appears to be a relatively safe and effective modality for difficult biliary stones.


Sign in / Sign up

Export Citation Format

Share Document