A digital control technique for a single-phase PWM inverter

1998 ◽  
Vol 45 (4) ◽  
pp. 672-674 ◽  
Author(s):  
K.S. Low
2016 ◽  
Vol 136 (2) ◽  
pp. 110-117 ◽  
Author(s):  
Takahiro Tanaka ◽  
Shoko Koga ◽  
Ryosuke Kogi ◽  
Shunya Odawara ◽  
Keisuke Fujisaki

Author(s):  
Wei Yao ◽  
Zhaoming Qian

In this paper, an improved load sharing control scheme is presented, which is able to improve the transient response and power sharing accuracy of parallel-connected inverters used in microgrid. It also shows how the improved droop method can be easily adapted to account for the operation of parallel-connected inverters, providing good performance under the variation and disturbance of loads, as well as achieving good steady-state objectives and transient performance. Two DSP-based single-phase Microgrid inverters are designed and implemented. Simulation and experimental results are all reported, confirming the validity of the proposed control technique.