scholarly journals Comperative analysis of accuracy between low-frequency ultrasound biomicroscopy and 14-MHz ultrasonography with tissue harmonic imaging for the evaluation of the posterior lens capsule in traumatic cataracts

2021 ◽  
Vol 21 (1) ◽  
Author(s):  
Bin Wu ◽  
Xiaoyong Yuan ◽  
Song Chen

Abstract Background To compare the accuracy of low-frequency ultrasound biomicroscopy (LFUBM) and 14-MHz ultrasonography with tissue harmonic imaging (14-MHz + THI) in the assessment of posterior capsule (PC) integrity in patients with traumatic cataracts (TCs). Methods From January 2019 to October 2020, 51 patients (51 eyes) with TCs who were scheduled for cataract extraction and for whom the PC of the lens could not be observed by the slit lamp visited Tianjin Eye Hospital, including 47 patients (47 eyes) with a penetrating injury of the eyeball and 4 patients (4 eyes) with a blunt injury of the eyeball. All eyes underwent LFUBM and 14-MHz + THI examinations before cataract extraction to determine the integrity of the PC. The integrity of the PC observed in surgery was the actual findings, and the consistency between the 2 methods was assessed in terms of the preoperative examination and intraoperative findings. Fisher’s exact test was used for consistency analysis, and P < 0.05 was considered statistically significant. Results Thirty-two eyes with ruptured PCs and 19 eyes with intact PCs were actual findings in surgery. Thirty eyes with ruptured PCs and 21 eyes with intact PCs were examined by LFUBM. Thirty-two eyes with ruptured PCs and 19 eyes with intact PCs were examined by 14-MHz + THI. There were no significant differences between the 2 methods and the intraoperative findings (P = 0.293 LFUBM, P = 0.623 14-MHz + THI). The sensitivity, specificity, positive predictive value, negative predictive value and accuracy of LFUBM and 14-MHz + THI were 91 and 94%, 95 and 89%, 97 and 94%, 86 and 89% and 92 and 92%, respectively. Conclusions Both LFUBM and 14-MHz + THI were proved to have high levels sensitivity and specificity in diagnosing the status of the PC in TC and they can be used as accurate diagnostic tool in these cases.

2020 ◽  
pp. 13-23
Author(s):  
Natalya Kornova ◽  
A. Krylov

The article presents results of a study on the effectiveness of using lowfrequency ultrasound and photochromotherapy in the complex treatment of patients with chronic bacterial and viral rhinosinusitis. The study involved 69 people aged 18 to 55 years: 39 (56.83 %) women and 30 (45.11 %) men with chronic rhinosinusitis during the period of clinical exacerbation and concomitant chronic tonsillitis without exacerbation. All patients included in the study underwent X-ray examination or computed tomography and magnetic resonance imaging of the paranasal sinuses. 100 % of the patients were examined for the presence of antibodies to Human gammaherpesvirus 4 (ELISA), had study of blood serum for IgM and IgG and test to determine the avidity of Ig G antibodies to γ-herpesviruses. The obtained data indicate the effectiveness of including low-frequency ultrasound and photochromotherapy in the complex treatment of patients with chronic rhinosinusitis and concomitant chronic tonsillitis of bacterial and viral nature without exacerbation.


Author(s):  
Mohd Razealy Anuar ◽  
Mohamed Hussein Abdurahman ◽  
Nor Irwin Basir ◽  
Ahmad Zuhairi Abdullah

2003 ◽  
Vol 29 (5) ◽  
pp. S120-S121
Author(s):  
S. Bashardoust Tajali ◽  
S. Kazemi ◽  
A. Azari ◽  
A. Shahverdi ◽  
M. Jabal Ameli

2017 ◽  
Vol 284 ◽  
pp. 92-99 ◽  
Author(s):  
M. Bellardita ◽  
H.A. El Nazer ◽  
V. Loddo ◽  
F. Parrino ◽  
A.M. Venezia ◽  
...  

2014 ◽  
Vol 239 (6) ◽  
pp. 747-757 ◽  
Author(s):  
Zhi-Yong Shen ◽  
Gan-Lin Xia ◽  
Ming-Feng Wu ◽  
Min-Xin Shi ◽  
Fu-Lin Qiang ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document