scholarly journals Torque Loss After Miniscrew Placement: An In-Vitro Study Followed by a Clinical Trial

2016 ◽  
Vol 10 (1) ◽  
pp. 251-260 ◽  
Author(s):  
Marco Migliorati ◽  
Sara Drago ◽  
Fabrizio Barberis ◽  
Irene Schiavetti ◽  
Domenico Dalessandri ◽  
...  

To evaluate torque loss a week after insertion, both in an in vivo and an in vitro experimental setup were designed. In the in vivo setup a total of 29 miniscrews were placed in 20 patients who underwent orthodontic treatment. Maximum insertion torque (MIT) was evaluated at insertion time (T1). A week later, insertion torque was measured again by applying a quarter turn (T2); no load was applied on the screw during the first week. In the in vitro setup a total of 20 miniscrews were placed in pig rib bone samples. MIT was evaluated at insertion time (T1). Bone samples were kept in saline solution and controlled environment for a week during which the solution was refreshed every day. Afterwards, torque was measured again by applying a quarter turn (T2). The comparison of MIT over time was done calculating the percentage difference of the torque values between pre- and post-treatment and using the parametric two independent samples t-test or the non-parametric Mann–Whitney test. After a week unloaded miniscrews showed a mean loss of rotational torque of 36.3% and 40.9% in in vitro and in in vivo conditions, respectively. No statistical differences were found between the two different setups. Torque loss was observed after the first week in both study models; in vitro experimental setup provided a reliable study model for studying torque variation during the first week after insertion.

Materials ◽  
2020 ◽  
Vol 13 (14) ◽  
pp. 3205 ◽  
Author(s):  
Seen-Young Kang ◽  
Ji-Min Yu ◽  
Hyoung-Sik Kim ◽  
Jun-Seok Lee ◽  
Chan-Mi Yeon ◽  
...  

This study aims to compare the torque values for various lengths of the titanium-based orthodontic anchor screw (OAS), different anchorage methods and varying artificial bone densities after predrilling. Furthermore, the effects of these parameters on bone stability are evaluated. A total of 144 OASs were prepared with a diameter of 1.6 mm and heights of 6, 8 and 10 mm. Artificial bones were selected according to their density, corresponding to Grades 50, 40 and 30. Torque values for the automatic device and manual anchorage methods exhibited a statistically significant difference for the same-sized OAS, according to the bone density of the artificial bones (p < 0.05). However, when insertion torque was at the maximum rotations, there was no significant difference in the torque values for the Grade 30 artificial bone (p > 0.05). When the torque values of both anchorage methods were statistically compared with the mean difference for each group, the results of the manual anchorage method were significantly higher than those of the automatic device anchorage method (p < 0.05). A statistically significant difference was observed in the bone stability resulting from different OAS anchorage methods and artificial bone lengths. These findings suggest that the automatic anchorage method should be used when fixing the OAS.


2020 ◽  
Vol 8 (4) ◽  
pp. 138
Author(s):  
Alessandra Marchi ◽  
Matteo Camporesi ◽  
Maurizio Festa ◽  
Luis Salvatierra ◽  
Sara Izadi ◽  
...  

The aims of this study were to assess the values and mechanical properties of insertion torque (IT) of steel miniscrews inserted in artificial bone blocks (Sawbones, Pacific Research Laboratories, Vashon, WA, USA) with different bone densities and to detect any scratches on the surface of the miniscrews after insertion. Forty self-drilling miniscrews (Leone S.p.A. ø 1.75 mm, L 8 mm) have been inserted into bone blocks that mimic different stability conditions (density: 20 PCF—pounds per cubic foot, 40 PCF, and 30 + 50 PCF with 2 mm and 4 mm of cortical bone). Before insertion and after removal, all miniscrews were inspected with a stereomicroscope 5x and a SEM to detect potential microscopic cracks. Using an electronic surgical motor (W&H Dentalwerk Bürmoos GmbH, Werner Bader Str. 1, 5111 Bürmoos, Austria), the maximum insertion torque value was registered. Stereomicroscope and SEM examination did not indicate any morphological and surface structural changes to the miniscrews, irrespective of the bone density they were inserted into. The findings showed that IT increased significantly with increasing bone density. In each artificial bone block, morphostructural analysis demonstrated the adequate mechanical properties of the self-drilling miniscrews. IT measurements indicated torque values between 6 and 10 Ncm for blocks with a density of 30 + 50 PCF, whereas the suggested values are between 5 and 10 Ncm.


2020 ◽  
Vol 8 (1) ◽  
pp. 21 ◽  
Author(s):  
Ferdinando Attanasio ◽  
Alessandro Antonelli ◽  
Ylenia Brancaccio ◽  
Fiorella Averta ◽  
Michele Mario Figliuzzi ◽  
...  

Background: The aim of this in vitro study was to analyse the primary stability of 20 implants placed with Twist drills (TD) versus 20 implants placed with Summers osteotomes (SO) and 20 implants placed with B&B bone compactors (BC) in medullary bone (quality type III and type IV). Methods: The implants were placed in 10 fresh pig ribs fixed on a bench vice in order to avoid micro-movements during surgical procedures and measure recording. Peak insertion torque (PIT) and Peak removal torque (PRT) were recorded with MGT-12 digital torque gauge and ISQ was recorded through OSSTELL ISQ™ device by an independent operator. Results: Comparing our data (Tukey test p = 0.05), it was evidenced a statistically significant difference in the PIT between TD and BC groups (p = 0.01). Analysing ISQ data, there was a statistically significant difference between the TD and BC groups (p = 0.0001) and between the SO and BC groups (p = 0.014). The analysis of PRT evidenced a statistically significant difference between the TD and BC groups (p = 0.038). Conclusions: This study evidenced that bone compactor preparation can positively influence primary implant stability (PS), however further in vivo studies and a larger sample are necessary to assess the usefulness in several clinical settings.


2014 ◽  
Author(s):  
Ivo Dumic-Cule ◽  
Dunja Rogic ◽  
Damir Jezek ◽  
Lovorka Grgurevic ◽  
Slobodan Vukicevic

Author(s):  
Arda Ozdiler ◽  
suleyman dayan ◽  
Burc Gencel ◽  
Gulbahar Isık-Ozkol

This in vitro study evaluated the influence of taper angles on the internal conical connections of implant systems and of the application of chlorhexidine gel as an antibacterial agent or a polyvinyl siloxane (PVS) sealant on the reverse torque values of abutment screws after dynamic loading. The current study tested four implant systems with different taper angles (5.4°, 12°, 45°, and 60°). Specimens were divided into three groups: control (neither chlorhexidine gel filled nor silicone sealed), 2% chlorhexidine gel-filled or silicone-sealed group, and group subjected to a dynamic load of 50 N at 1 Hz for 500,000 cycles prior to reverse torque measurements. Quantitative positive correlation was observed between the taper angle degree and the percentage of tightening torque loss. However, this correlation was significant only for the 60° connection groups except in the group in which a sealant was applied ( p = 0.013 for the control group, p = 0.007 for the chlorhexidine group). Percentages of decrease in the torque values of the specimens with silicone sealant application were significantly higher compared with both the control and chlorhexidine groups ( p = 0.001, p = 0.002, p = 0.001, and p = 0.002, respectively, according to the increasing taper angles); the percentage of decrease in torque values due to chlorhexidine application was statistically insignificant when compared with the control group. The application of gel-form chlorhexidine as an antibacterial agent does not significantly affect the stability of the implant–abutment connection under dynamic loads. PVS sealants may cause screw loosening under functional loads.


2019 ◽  
Vol 9 (1) ◽  
Author(s):  
Elodie A. Pérès ◽  
Jérôme Toutain ◽  
Louis-Paul Paty ◽  
Didier Divoux ◽  
Méziane Ibazizène ◽  
...  

Abstract Background Diacetyl-bis(N4-methylthiosemicarbazone), labeled with 64Cu (64Cu-ATSM) has been suggested as a promising tracer for imaging hypoxia. However, various controversial studies highlighted potential pitfalls that may disable its use as a selective hypoxic marker. They also highlighted that the results may be tumor location dependent. Here, we first analyzed uptake of Cu-ATSM and its less lipophilic counterpart Cu-Cl2 in the tumor over time in an orthotopic glioblastoma model. An in vitro study was also conducted to investigate the hypoxia-dependent copper uptake in tumor cells. We then further performed a comprehensive ex vivo study to compare 64Cu uptake to hypoxic markers, specific cellular reactions, and also transporter expression. Methods μPET was performed 14 days (18F-FMISO), 15 days (64Cu-ATSM and 64Cu-Cl2), and 16 days (64Cu-ATSM and 64Cu-Cl2) after C6 cell inoculation. Thereafter, the brains were withdrawn for further autoradiography and immunohistochemistry. C6 cells were also grown in hypoxic workstation to analyze cellular uptake of Cu complexes in different oxygen levels. Results In vivo results showed that Cu-ASTM and Cu-Cl2 accumulated in hypoxic areas of the tumors. Cu-ATSM also stained, to a lesser extent, non-hypoxic regions, such as regions of astrogliosis, with high expression of copper transporters and in particular DMT-1 and CTR1, and also characterized by the expression of elevated astrogliosis. In vitro results show that 64Cu-ATSM showed an increase in the uptake only in severe hypoxia at 0.5 and 0.2% of oxygen while for 64Cu-Cl2, the cell retention was significantly increased at 5% and 1% of oxygen with no significant rise at lower oxygen percentages. Conclusion In the present study, we show that Cu-complexes undoubtedly accumulate in hypoxic areas of the tumors. This uptake may be the reflection of a direct dependency to a redox metabolism and also a reflection of hypoxic-induced overexpression of transporters. We also show that Cu-ATSM also stained non-hypoxic regions such as astrogliosis.


2021 ◽  
Vol 22 (3) ◽  
pp. 1083
Author(s):  
Sukkum Ngullie Chang ◽  
Se Ho Kim ◽  
Debasish Kumar Dey ◽  
Seon Min Park ◽  
Omaima Nasif ◽  
...  

Polymethoxyflavanoids (PMFs) have exhibited a vast array of therapeutic biological properties. 5-O-Demethylnobiletin (5-DN) is one such PMF having anti-inflammatory activity, yet its role in hepatoprotection has not been studied before. Results from in vitro study revealed that 5-DN did not exert a high level of cytotoxicity on HepG2 cells at 40 μM, and it was able to rescue HepG2 cell death induced by carbon tetrachloride (CCl4). Subsequently, we investigated acute liver injury on BALB/c mice induced by CCl4 through the intraperitoneal injection of 1 mL/kg CCl4 and co-administration of 5-DN at (1 and 2 mg/kg) by oral gavage for 15 days. The results illustrated that treatment with 5-DN attenuated CCl4-induced elevated serum aminotransferase (AST)/alanine aminotransferase (ALT) ratio and significantly ameliorated severe hepatic damage such as inflammation and fibrosis evidenced through lesser aberrations in the liver histology of 5-DN dose groups. Additionally, 5-DN efficiently counteracted and equilibrated the production of ROS accelerated by CCl4 and dramatically downregulated the expression of CYP2E1 vitally involved in converting CCl4 to toxic free radicals and also enhanced the antioxidant enzymes. 5-DN treatment also inhibited cell proliferation and inflammatory pathway abnormally regulated by CCl4 treatment. Furthermore, the apoptotic response induced by CCl4 treatment was remarkably reduced by enhanced Bcl-2 expression and noticeable reduction in Bax, Bid, cleaved caspase 3, caspase 9, and apaf-1 expression. 5-DN treatment also induced the conversion of LC3 and promoted the autophagic flux. Conclusively, 5-DN exhibited hepatoprotective effects in vitro and in vivo and prevented liver fibrosis induced by CCl4.


2021 ◽  
Vol 16 (1) ◽  
Author(s):  
Mira Puthettu ◽  
Stijn Vandenberghe ◽  
Stefanos Demertzis

Abstract Background During cardiac surgery, micro-air emboli regularly enter the blood stream and can cause cognitive impairment or stroke. It is not clearly understood whether the most threatening air emboli are generated by the heart-lung machine (HLM) or by the blood-air contact when opening the heart. We performed an in vitro study to assess, for the two sources, air emboli distribution in the arterial tree, especially in the brain region, during cardiac surgery with different cannulation sites. Methods A model of the arterial tree was 3D printed and included in a hydraulic circuit, divided such that flow going to the brain was separated from the rest of the circuit. Air micro-emboli were injected either in the HLM (“ECC Bubbles”) or in the mock left ventricle (“Heart Bubbles”) to simulate the two sources. Emboli distribution was measured with an ultrasonic bubble counter. Five repetitions were performed for each combination of injection site and cannulation site, where air bubble counts and volumes were recorded. Air bubbles were separated in three categories based on size. Results For both injection sites, it was possible to identify statistically significant differences between cannulation sites. For ECC Bubbles, axillary cannulation led to a higher amount of air bubbles in the brain with medium-sized bubbles. For Heart Bubbles, aortic cannulation showed a significantly bigger embolic load in the brain with large bubbles. Conclusions These preliminary in vitro findings showed that air embolic load in the brain may be dependent on the cannulation site, which deserves further in vivo exploration.


Sign in / Sign up

Export Citation Format

Share Document