scholarly journals Assessment of Recurrent Laryngeal Nerve During Thyroid Surgery With Laryngeal Mask Airway

2007 ◽  
Vol 133 (3) ◽  
pp. 266 ◽  
Author(s):  
Leonard Pott ◽  
John T. Swick ◽  
Brendan C. Stack
1996 ◽  
Vol 110 (4) ◽  
pp. 383-384 ◽  
Author(s):  
Hamid Daya ◽  
William J. Fawcett ◽  
Neil Weir

AbstractWe report two cases of left vocal fold palsy following use of the laryngeal mask airway. In both cases anaesthesia was uneventful with a duration of about 60 minutes. It is proposed that high intra-cuff pressures induced during anaesthesia resulted in distension of the hypopharynx and subsequent neuropraxia of the motor branches of the recurrent laryngeal nerve and the external branch of the superior laryngeal nerve.