Quality Control of Magnetic Resonance Elastography Using Percent Measurable Liver Volume Estimation

Author(s):  
David H. Ballard ◽  
Daniel R. Ludwig ◽  
Tyler J. Fraum ◽  
Amber Salter ◽  
Vamsi R. Narra ◽  
...  
2019 ◽  
Vol 8 (5) ◽  
pp. 739 ◽  
Author(s):  
Sudhakar K. Venkatesh ◽  
Safa Hoodeshenas ◽  
Sandeep H. Venkatesh ◽  
Angela Dispenzieri ◽  
Morie A. Gertz ◽  
...  

In this paper, we present our preliminary findings regarding magnetic resonance elastography (MRE) on the livers of 10 patients with systemic amyloidosis. Mean liver stiffness measurements (LSM) and spleen stiffness measurements (SSM) were obtained. Magnetic resonance imaging (MRI) images were analyzed for the distribution pattern of amyloid deposition. Pearson correlation analysis was performed in order to study the correlation between LSM, SSM, liver span, liver volume, spleen span, spleen volume, serum alkaline phosphatase (ALP), N-terminal pro b-type natriuretic peptide (NT pro BNP), and the kappa and lambda free light chains. An increase in mean LSM was seen in all patients. Pearson correlation analysis showed a statistically significant correlation between LSM and liver volume (r = 0.78, p = 0.007) and kappa chain level (r = 0.65, p = 0.04). Interestingly, LSM did not correlate significantly with SSM (r = 0.45, p = 0.18), liver span (r = 0.57, p = 0.08), or serum ALP (r = 0.60, p = 0.07). However, LSM correlated significantly with serum ALP when corrected for liver volume (partial correlation, r = 0.71, p = 0.03) and NT pro BNP levels (partial correlation, r = 0.68, p = 0.04). MRI review revealed that amyloid deposition in the liver can be diffuse, lobar, or focal. MRE is useful for the evaluation of hepatic amyloidosis and shows increased stiffness in hepatic amyloidosis. MRE has the potential to be a non-invasive quantitative imaging marker for hepatic amyloidosis.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Guillaume Flé ◽  
Guillaume Gilbert ◽  
Pol Grasland-Mongrain ◽  
Guy Cloutier

AbstractQuantitative mechanical properties of biological tissues can be mapped using the shear wave elastography technique. This technology has demonstrated a great potential in various organs but shows a limit due to wave attenuation in biological tissues. An option to overcome the inherent loss in shear wave magnitude along the propagation pathway may be to stimulate tissues closer to regions of interest using alternative motion generation techniques. The present study investigated the feasibility of generating shear waves by applying a Lorentz force directly to tissue mimicking samples for magnetic resonance elastography applications. This was done by combining an electrical current with the strong magnetic field of a clinical MRI scanner. The Local Frequency Estimation method was used to assess the real value of the shear modulus of tested phantoms from Lorentz force induced motion. Finite elements modeling of reported experiments showed a consistent behavior but featured wavelengths larger than measured ones. Results suggest the feasibility of a magnetic resonance elastography technique based on the Lorentz force to produce an shear wave source.


Author(s):  
Akihisa Koga ◽  
Yoshiaki Itoigawa ◽  
Mikio Suga ◽  
Daichi Morikawa ◽  
Hirohisa Uehara ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document