Comparative Study of Blood Flow Through Normal, Stenosis Affected and Bypass Grafted Artery Using Computational Fluid Dynamics

Author(s):  
Anirban Banik ◽  
Tarun Kanti Bandyopadhyay ◽  
Vladimir Panchenko
Dynamics ◽  
2021 ◽  
Vol 1 (1) ◽  
pp. 9-17
Author(s):  
Andrea Natale Impiombato ◽  
Giorgio La Civita ◽  
Francesco Orlandi ◽  
Flavia Schwarz Franceschini Zinani ◽  
Luiz Alberto Oliveira Rocha ◽  
...  

As it is known, the Womersley function models velocity as a function of radius and time. It has been widely used to simulate the pulsatile blood flow through circular ducts. In this context, the present study is focused on the introduction of a simple function as an approximation of the Womersley function in order to evaluate its accuracy. This approximation consists of a simple quadratic function, suitable to be implemented in most commercial and non-commercial computational fluid dynamics codes, without the aid of external mathematical libraries. The Womersley function and the new function have been implemented here as boundary conditions in OpenFOAM ESI software (v.1906). The discrepancy between the obtained results proved to be within 0.7%, which fully validates the calculation approach implemented here. This approach is valid when a simplified analysis of the system is pointed out, in which flow reversals are not contemplated.


2004 ◽  
Vol 126 (2) ◽  
pp. 180-187 ◽  
Author(s):  
Xinwei Song ◽  
Houston G. Wood ◽  
Don Olsen

The continuous flow ventricular assist device (VAD) is a miniature centrifugal pump, fully suspended by magnetic bearings, which is being developed for implantation in humans. The CF4 model is the first actual prototype of the final design product. The overall performances of blood flow in CF4 have been simulated using computational fluid dynamics (CFD) software: CFX, which is commercially available from ANSYS Inc. The flow regions modeled in CF4 include the inlet elbow, the five-blade impeller, the clearance gap below the impeller, and the exit volute. According to different needs from patients, a wide range of flow rates and revolutions per minute (RPM) have been studied. The flow rate-pressure curves are given. The streamlines in the flow field are drawn to detect stagnation points and vortices that could lead to thrombosis. The stress is calculated in the fluid field to estimate potential hemolysis. The stress is elevated to the decreased size of the blood flow paths through the smaller pump, but is still within the safe range. The thermal study on the pump, the blood and the surrounding tissue shows the temperature rise due to magnetoelectric heat sources and thermal dissipation is insignificant. CFD simulation proved valuable to demonstrate and to improve the performance of fluid flow in the design of a small size pump.


Author(s):  
Vishwajeet Shankhwar ◽  
Dilbag Singh ◽  
Renuka Garg ◽  
Kamleshwar Kumar Verma ◽  
K.K. Deepak

2020 ◽  
Vol 222 (1) ◽  
pp. S591-S592
Author(s):  
Lucille E. Anzia ◽  
Ryan Pewowaruk ◽  
Katrina L. Ruedinger ◽  
Barbara Trampe ◽  
Timothy Heiser ◽  
...  

Author(s):  
Daisuke Mori ◽  
Tomoaki Hayasaka ◽  
Takami Yamaguchi

The vascular diseases occurred in large arteries are suggested to relate with the blood flow as well as the vessel structure, which significantly influences the flow. In order to investigate these interactions, we have to understand the detailed flow phenomena in the complex vessel configuration.


Sign in / Sign up

Export Citation Format

Share Document