Thermally stable and acidic pH tolerant mutant phytases with high catalytic efficiency from Yersinia intermedia for potential application in feed industries

Author(s):  
Marjan Abbasi Kheirabadi ◽  
Behnaz Saffar ◽  
Roohullah Hemmati ◽  
Mojtaba Mortazavi
2012 ◽  
Vol 159 (1-2) ◽  
pp. 50-55 ◽  
Author(s):  
Huiyong Jia ◽  
Yinan Li ◽  
Yuchun Liu ◽  
Qiaojuan Yan ◽  
Shaoqing Yang ◽  
...  

2009 ◽  
Vol 00 (00) ◽  
pp. 090513010017019-7
Author(s):  
Biagio Solarino ◽  
Giancarlo Di Vella ◽  
Thea Magrone ◽  
Felicita Jirillo ◽  
Angela Tafaro ◽  
...  

1994 ◽  
Vol 72 (06) ◽  
pp. 862-868 ◽  
Author(s):  
Frederick A Ofosu ◽  
J C Lormeau ◽  
Sharon Craven ◽  
Lori Dewar ◽  
Noorildan Anvari

SummaryFactor V activation is a critical step preceding prothrombinase formation. This study determined the contributions of factor Xa and thrombin, which activate purified factor V with similar catalytic efficiency, to plasma factor V activation during coagulation. Prothrombin activation began without a lag phase after a suspension of coagulant phospholipids, CaCl2, and factor Xa was added to factor X-depleted plasma. Hirudin, a potent thrombin inhibitor, abrogated prothrombin activation initiated with 0.5 and 1.0 nM factor Xa, but not with 5 nM factor Xa. In contrast, hirudin did not abrogate prothrombin activation in plasmas pre-incubated with 0.5,1.0 or 5 nM α-thrombin for 10 s followed by the coagulant suspension containing 0.5 nM factor Xa. Thus, thrombin activates plasma factor V more efficiently than factor Xa. At concentrations which doubled the clotting time of contact-activated normal plasma, heparin and three low Mr heparins also abrogated prothrombin activation initiated with 0.5 nM factor Xa, but not with 5 nM factor Xa. If factor V in the factor X-depleted plasma was activated (by pre-incubation with 10 nM a-thrombin for 60 s) before adding 0.5,1.0, or 5 nM factor Xa, neither hirudin nor the heparins altered the rates of prothrombin activation. Thus, none of the five anticoagulants inactivates prothrombinase. When 5 or 10 pM relipidated r-human tissue factor and CaCl2 were added to normal plasma, heparin and the three low Mr heparins delayed the onset of prothrombin activation until the concentration of factor Xa generated exceeded 1 nM, and they subsequently inhibited prothrombin activation to the same extent. Thus, hirudin, heparin and low Mr heparins suppress prothrombin activation solely by inhibiting prothrombinase formation.


1966 ◽  
Vol 15 (01/02) ◽  
pp. 252-272
Author(s):  
K. M Moser ◽  
Mary Belle Frey

Summary1. Caseinolytic and fibrinolytic systems for assay of plasmin in fibrinolytic agents are described which are based upon the determinations of AE/min during the linear portion of the casein-plasmin and fibrin-plasmin reaction curves respectively. A " caseinolytic-rate " unit and “fibrinolytic-rate " unit of ÄE/min × 103 during the linear portion of the respective curves are proposed.2. Data are presented indicating that a reliably linear relationship exists between plasmin concentration and these caseinolytic - and fibrinolytic-rate units.3. Data comparing results obtained with the proposed assay techniques and previously-used casein and fibrinolytic techniques are presented.4. Formulae by which caseinolytic-rate and fibrinolytic-rate units can be roughly converted into Remmert-Cohen type plasmin units are offered.5. The theoretical and practical problems which have influenced development of assays for fibrinolytic components are discussed.6. The advantages of the plasmin “rate unit” techniques vis a vis existing assays are delineated.7. The potential application of the techniques to measurements other than the plasmin content of fibrinolytic agents is discussed.


1998 ◽  
Vol 512 ◽  
Author(s):  
C. Hecht ◽  
R. Kummer ◽  
A. Winnacker

ABSTRACTIn the context of spectral-hole burning experiments in 4H- and 6H-SiC doped with vanadium the energy positions of the V4+/5+ level in both polytypes were determined in order to resolve discrepancies in literature. From these numbers the band offset of 6H/4H-SiC is calculated by using the Langer-Heinrich rule, and found to be of staggered type II. Furthermore the experiments show that thermally stable electronic traps exist in both polytypes at room temperature and considerably above, which may result in longtime transient shifts of electronic properties.


2020 ◽  
Vol 25 (2) ◽  
pp. 95-109
Author(s):  
Sapnita Shinde ◽  
Saurabh Saxena ◽  
Vineeta Dixit ◽  
Atul K. Tiwari ◽  
Naveen K. Vishvakarma ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document