Analysis and stabilization control of a voltage source controlled wind farm under weak grid conditions

Author(s):  
Shun Sang ◽  
Chen Zhang ◽  
Jianwen Zhang ◽  
Gang Shi ◽  
Fujin Deng
2013 ◽  
Vol 860-863 ◽  
pp. 267-270
Author(s):  
Xiao Yan Bian ◽  
Li Jun Hong ◽  
Yang Fu

Reactive and active power variation of large scale wind farms always lead to the instability of voltage and frequency. To solve this problem, this paper proposed a method of joining with frequency and voltage control loop of Voltage Source Converter HVDC (VSC-HVDC). Control loop of VSC-HVDC converter WFVSC (Wind Farm Side VSC) and GSVSC (Grid Side VSC) were detailed designed. By the frequency loop of WFSVSC, transient stability is greatly improved. Finally, based on the DIgSILENT/Power Factory simulation, the results show its validity and effectiveness.


Author(s):  
Ayaka Nakamura ◽  
Atsushi Umemura ◽  
Rion Takahashi ◽  
Junji Tamura ◽  
Yoshiharu Matsumura ◽  
...  

Energies ◽  
2020 ◽  
Vol 13 (13) ◽  
pp. 3316 ◽  
Author(s):  
Dong Wang ◽  
Xiaojie Zhang ◽  
Lei Yang ◽  
Yunhui Huang ◽  
Wei Huang ◽  
...  

Recent studies show that the loss of stability for a voltage-source converter (VSC) in weak-grid connection is largely related to its synchronization unit, i.e., the phase-locked loop (PLL). This paper studies the synchronization stability of a system comprised by two VSCs in parallel connection to a weak grid. A reduced transfer function based small-signal model, which can allow for the interactions between PLL and converter outer power controls, is first proposed. Then, an improved net damping criterion is used to analyze the damping and stability characters of such system under various operating conditions and different controller configurations. Compared to the conventional net damping criterion, the used criterion has wider applicability in terms of stability judgment. Case studies show that the studied system tends to be unstable at weak-grid or heavy-loading conditions. The instability can be in the form of oscillations or monotonic divergence, in which, the latter is more likely to occur for the converters without grid voltage regulation capabilities. Besides, the net damping-based sensitivity studies can provide guidance on control tuning or design for stability enhancement. Detailed model-based time domain simulations are conducted to verify the analysis results.


Energies ◽  
2019 ◽  
Vol 12 (23) ◽  
pp. 4458 ◽  
Author(s):  
Yang ◽  
Yuan

The effect of frequency variation on system stability becomes crucial when a voltage source converter (VSC) is connected to a weak grid. However, previous studies lack enough mechanism cognitions of this effect, especially on the stability issues in DC voltage control (DVC) timescale (around 100 ms). Hence, this paper presented a thorough analysis of the effect mechanism of frequency variation on the weak grid-connected VSC system stability in a DVC timescale. Firstly, based on instantaneous power theory, a novel method in which the active/reactive powers are calculated with the time-varying frequency of voltage vectors was proposed. This method could intuitively reflect the effect of frequency variation on the active/reactive powers and could also help reduce the system order to a certain extent. Then, a small-signal model was established based on the motion equation concept, to depict the effect of frequency variation on the weak grid-connected VSC system dynamics. Furthermore, an analytical method was utilized to quantify the effect of frequency variation on the system’s small-signal stability. The quantitative analysis considered the interactions between the DC voltage control, the terminal voltage control, phase-locked loop, and the power network. Finally, case studies were conducted, and simulation results supported the analytical analyses.