Vertical Geometric Irregularity Effect on Performance-Based Seismic Design for Moderate Rise RC Moment Resisting Frame Buildings

Author(s):  
Momen Mohamed. M. Ahmed ◽  
Mohamed Abdel-Basset Abdo ◽  
Waleed Abo El-Wafa Mohamed
Teras Jurnal ◽  
2018 ◽  
Vol 7 (2) ◽  
pp. 263
Author(s):  
Mul Muliadi Adi ◽  
M. Kabir Kabir Ihsan

Bangunan yang hancur oleh gempa dapat dicegah dengan memperkuat struktur bangunan terhadap gaya gempa yang bekerja padanya. Perkuatan bangunan dapat dilakukan dengan memperkaku bangunan dalam arah lateral yaitu <em>moment resisting frame</em> (<em>rigid frame</em>), <em>braced frame</em> dan <em>shear wall</em>. Bangunan dinding geser merupakan salah satu jenis <em>bangunan</em> tahan gempa gedung beton bertulang menggunakan sistem rangka struktur yang dikombinasikan. Kinerja gedung akan bertambah dan menjadi optimal jika pola penempatan <em>dinding geser</em> serta metode analisanya tepat. Sistem lainnya dalam mengurangi kerusakan bangunan akibat gempa dengan <em>performance based seismic design</em> yaitu dengan menggunakan <em>base isolator.</em>, yang memanfaatkan teknik analisa non-linear berbasis komputer untuk menganalisa perilaku inelastis struktur dari berbagai macam intensitas gerakan tanah (<em>gempa</em>), sehingga dapat diketahui kinerjanya pada kondisi kritis. Tujuan penelitian ini dilakukan untuk mengetahui perioda dalam penggunaan <em>base isolator </em>dengan yang tanpa menggunakan <em>base isolator,</em> pada bangunan sistem ganda, lantai 10 tingkat, bentuk beraturan pada bangunan dinding geser. Analisis data yang dilakukan dengan menggunakan bantuan <em>software </em>komputer <em>SAP2000</em>. Pembebanan pada gedung didasarkan pada peraturan bangunan gedung beton bertulang dan analisa dinamik <em>Time History Modal Analysi</em>s struktur dalam Tata Cara Perencanaan Ketahanan Gempa Untuk Struktur Bangunan Gedung Dan Non Gedung (SNI 1726:2012). Dari hasil penelitian ini dapat diketahui bahwa penggunaan <em>base isolator</em> memperbesar perioda alami. Nilai perioda pada dinding geser dan dinding geser <em>base isolator</em> besarnya berturut-turut 0.988 detik dan 2.465 detik. Hal ini menyebabkan gaya gempa yang bekerja menjadi lebih kecil.


1992 ◽  
Vol 19 (4) ◽  
pp. 688-710 ◽  
Author(s):  
T. J. Zhu ◽  
W. K. Tso ◽  
A. C. Heidebrecht

Seismic areas in Canada are classified into three categories for three different combinations of acceleration and velocity seismic zones (Za < Zv, Za = Zv, and Za > Zv), and ground motions in different zonal combination areas are expected to have different frequency characteristics. The National Building Code of Canada specifies different levels of seismic design base shear for short-period buildings located in areas with different zonal combinations. The specification of seismic design base shear for long-period buildings is directly tied to zonal velocity, irrespective of seismic zonal combination. This paper evaluates the seismic performance of both high-rise long-period and low rise short-period reinforced concrete ductile moment-resisting frame buildings located in seismic regions having Za < Zv, Za = Zv, and Za > Zv. Two frame buildings have 10 and 18 storeys were used as structural models for high-rise buildings, while a set of four-storey buildings were used to represent low-rise buildings. All buildings were designed to the current Canadian seismic provisions and concrete material code. Three groups of earthquake records were selected as representative ground motions in the three zonal combination regions. The inelastic responses of the designed buildings to the three groups of ground motions were analyzed statistically. The results indicate that the distribution of inelastic deformations is significantly different for high-rise frame buildings situated in seismic regions with Za < Zv, Za = Zv, and Za > Zv. Inelastic deformation is concentrated in the lower storeys for high-rise buildings located in Za < Zv areas, whereas significant inelastic deformation can develop in the upper storeys for high-rise buildings situated in Za > Zv regions. The use of three different levels of seismic design base shear for short-period structures improves the consistency of ductility demands on low-rise buildings situated in the three different zonal combination regions. Despite the use of appropriate design base shears for different seismic regions, the ductility demands for these low-rise buildings are relatively high. To avoid excessive ductility demands, it is suggested that the seismic strengths for low-rise short-period buildings should not be significantly reduced from their elastic design base shears. Key words: earthquake, ground motion, seismic, design, reinforced concrete, frame buildings, beams, columns, ductility.


Sign in / Sign up

Export Citation Format

Share Document