Degradation analysis of Solar photovoltaic module under warm semiarid and tropical savanna climatic conditions of East Africa

Author(s):  
Samuel M. Ngure ◽  
Augustine B. Makokha ◽  
Edwin O. Ataro ◽  
Muyiwa S. Adaramola
2021 ◽  
Author(s):  
Madhura Yeligeti ◽  
Wenxuan Hu ◽  
Yvonne Scholz ◽  
Kai von Krbek

<p>Solar photovoltaic (PV) systems will foreseeably be an integral part of future energy systems. Land cover area analysis has a large influence on estimatiin of long-term solar photovoltaic potential of the world in high spatial detail. In this regard, it is often seen in contemporary works, that the suitability of various land cover categories for PV installation is considered in a yes/no binary response. While some areas like natural parks, sanctuaries, forests are usually completely exempted from PV potential calculations, other land over categories like urban settlements, bare, sparsely vegetated areas, and even cropland can principally support PV installations to varying degrees. This depends on the specific land use competition, social, economic and climatic conditions, etc. In this study, we attempt to evaluate these ‘factors of suitability’ of different land cover types for PV installations.</p><p>As a basis, the openly available global land cover datasets from the Copernicus Land Monitoring Service were used to identify major land cover types like cropland, shrubland, bare, wetlands, urban settlements, forests, moss and snow etc. For open area PV installations, with a focus on cropland, we incorporated the promising technology of ‘Agri-voltaics’ in our investigation. Different crops have shown to respond positively or negatively, so far, to growing under PV panels according to various experimental and commercial sources. Hence, we considered 18 major crops of the world (covering 85% of world cropland) individually and consequently, evaluated a weighted overall suitability factor of cropland cover for PV, for three acceptance scenarios of future.</p><p>For rooftop PV installations in urban areas, various socio-economic and geographical influences come in play. The rooftop area available and further usable for PV depends on housing patterns (roof type, housing density) which vary with climate, population density and socio-economic lifestyle. We classified global urban areas into several clusters based on combinations of these factors. For each cluster, rooftop area suitability is evaluated at a representative location using the land cover maps, the Open Street Map and specific characteristics of the cluster.</p><p>Overall, we present an interdisciplinary approach to integrate technological, social and economic aspects in land cover analysis to estimate PV potentials. While the intricacies may still be insufficient for planning small localized energy systems, this can reasonably benefit energy system modelling from a regional to international scale.</p>


2018 ◽  
Vol 240 ◽  
pp. 04004 ◽  
Author(s):  
Marek Jaszczur ◽  
Qusay Hassan ◽  
Janusz Teneta ◽  
Ewelina Majewska ◽  
Marcin Zych

The operating temperature of the photovoltaic module is an important issue because it is directly linked with system efficiency. The objective of this work is to evaluate temperature distribution in the photovoltaic module under different environmental conditions. The results shown that photovoltaic module operating temperature depends not only on the ambient temperature or solar radiation dependent but also depends on wind speed and wind direction. It is presented that the mounting conditions which are not taken into consideration by most of the literature models also play a significant role in heat transfer. Depends on mounting type an increase in module operating temperature in the range 10-15oC was observed which cause further PV system efficiency decrease of about 3.8-6.5 %.


Author(s):  
Mansour Zegrar ◽  
M’hamed Houari Zerhouni ◽  
Mohamed Tarik Benmessaoud ◽  
Fatima Zohra Zerhouni

In recent years, solar photovoltaic energy is becoming very important in the generation of green electricity. Solar photovoltaic effect directly converts solar radiation into electricity. The output of the photovoltaic module MPV depends on several factors as solar irradiation and cell temperature. A curve tracer is a system used to acquire the PV current-voltage characteristics, in real time, in an efficient manner. The shape of the I-V curve gives useful information about the possible anomalies of a PV device. This paper describes an experimental system developed to measure the current–voltage curve of a MPV under real conditions. The measurement is performed in an automated way. This present paper presents the design, and the construction of I-V simple curve tracer for photovoltaic modules. This device is important for photovoltaic (PV) performance assessment for the measurement, extraction, elaboration and diagnose of entire current-voltage I-V curves for several photovoltaic modules. This system permits to sweep the entire I-V curve, in short time, with different climatic and loads conditions. An experimental test bench is described. This tracer is simple and the experimental results present good performance. Simulation and experimental tests have been carried out. Experimental results presented good performance.


Author(s):  
D. V Tugay ◽  
S. I Korneliuk ◽  
O. O Shkurpela ◽  
V. S Akimov

Purpose. Creation of a detailed model of a solar photovoltaic station with a converter system based on a cascaded multi-level inverter with the MPPT (maximum power point tracker) function to investigate its operating modes in distributed power systems. Methodology. To carry out the research, the paper used the methods of system synthesis, mathematical and computer modeling to create photovoltaic station models and components; a physical experiment in obtaining thermal characteristics of the photovoltaic module Solarday SDM72360 W; modern power theories for synthesis of the vector control system of a multi-level inverter. Findings. the Matlab-model of solar photovoltaic station with transformerless 29-level cascade voltage inverter is synthesized. The model confirmed the serviceability and efficiency of the converter system and the power plant as a whole. An algorithm is proposed and an MPP tracker with volt-ampere characteristics of the photovoltaic module, which corresponds to the maximum power extraction, is synthesized on the basis of the algorithm. The algorithm was validated by the model for any solar radiation intensity. Originality. The total mathematical model of the photoelectric module, which accounts for its energy and heat characteristics, is obtained and can be used for simulating the operation of any computer model of the photoelectric converter under Matlab/Simulink/SimPowerSystems environment. Practical value. The model results indicate the prospects of industrial implementation of transformerless multi-level converter systems to be used in the structure of powerful solar photovoltaic stations.


2021 ◽  
Vol 7 ◽  
pp. 6921-6931
Author(s):  
Bernard Aboagye ◽  
Samuel Gyamfi ◽  
Eric Antwi Ofosu ◽  
Sinisa Djordjevic

1936 ◽  
Vol 27 (4) ◽  
pp. 611-632 ◽  
Author(s):  
Kenneth Mellanby

This is an account of laboratory experiments made with the tsetse Glossina palpalis. The results deal mainly with the effects of climatic conditions, temperature and humidity in particular, on the metabolism and life-cycle. Some work was also done on the activity and behaviour of the fly, but this is very incomplete, though it shows the importance of the problem and the need for further study.The work was done during a visit of just over a year to East Africa, in 1935-36, as Wandsworth Scholar of the London School of Hygiene and Tropical Medicine. I spent most of the time at the Human Trypanosomiasis Institute, Entebbe, Uganda, and also visited tsetse areas in Kenya and Tanganyika. I am grateful to all those who helped to make my visit profitable. Among others, to the Directors of Medical Services of the East African territories, in particular the Hon. W. H. Kauntze of Uganda, and many members of their departments. To Mr. C. B. Symes, Medical Entomologist, Kenya, and to Mr. W. H. Potts, of the Department of Tsetse Research, Tanganyika. I am especially grateful to Dr. H. Lyndhurst Duke, Director of the Human Trypanosomiasis Institute, for many kindnesses. Considerable assistance was received from Mrs. Helen Mellanby, who was working on allied problems at Entebbe. And mention must be made of the intelligent and conscientious help of my laboratory assistant, Omw. Bonaventure Semalwadde.


Sign in / Sign up

Export Citation Format

Share Document