Characterization of Acinetobacter indicus ZJB20129 for heterotrophic nitrification and aerobic denitrification isolated from an urban sewage treatment plant

2021 ◽  
pp. 126423
Author(s):  
Xia Ke ◽  
Cong Liu ◽  
Su-Qin Tang ◽  
Ting-Ting Guo ◽  
Li Pan ◽  
...  
Ecotoxicology ◽  
2016 ◽  
Vol 25 (10) ◽  
pp. 1849-1857 ◽  
Author(s):  
Dalel Belhaj ◽  
Khaled Athmouni ◽  
Bouthaina Jerbi ◽  
Monem Kallel ◽  
Habib Ayadi ◽  
...  

2013 ◽  
Vol 385-386 ◽  
pp. 857-861
Author(s):  
Xiao Ping Huang ◽  
Qi Xing Qing

On the basis of the computerized technological process control of sewage treatment in a urban sewage treatment plant in the Zone of Nanning, the author had brought forward a plan of PROFIBUS that based on automatic control system for sewage treatment, and designed the automatic control system diagram and the PROFIBUS network diagram for sewage treatment plant. At the same time, the author also made a study of techniques to control the sewage aeration, which was the most difficult problem in sewage treatment process. The fuzzy controller could indicate the changes of the water quality in treated sewage, effectively controlled the volume of aeration and then cut down the operation costs,it had produced good economic and social benefits.


2013 ◽  
Vol 361-363 ◽  
pp. 601-605
Author(s):  
Ji Ku Zhang ◽  
Yang Yang Li ◽  
Chen Zhang ◽  
Yan Bin Yang

By treating the secondary effluent of Sanbaotun sewage treatment plant in Fushun with the CS type UV Sterilizer, the experiment researches the influence on the removal rate which includes the factors of turbidity, chromaticity, initial E.coli concentration of raw water, UV dose. The results show that the turbidity does not influence on UV disinfection efficiency with the turbidity from 1.5NTU to 3.8NTU. In the low-dose UV disinfection process, the influent sewage turbidity should under 4NTU to ensure the disinfection efficiency. Low chromaticity does not affect the UV disinfection efficiency, with the influent sewage chromaticity is under 15 degrees.The initial E. coli has a certain impact on little doses of UV disinfection with the concentration from 175 × 104 A/ L to 230 × 104 A/ L, no impact on high doses of UV disinfection。


Author(s):  
Andrea Lanzini ◽  
Pierluigi Leone ◽  
Massimo Santarelli

A biogas coming from anaerobic digestion of urban sewage has been used to feed a SOFC planar anode-supported cell. The sewage is produced from the urban area of Torino (IT), and eventually collected and treated by SMAT (the municipal company managing the potable and waste water of the city). The biogas is produced by the thermophilic fermentation of the sludge which remains after the several treatments the sewage goes through in the above-mentioned plant. The biogas is of a high quality: it has on average a a methane content around 65% (the balance being essentially CO2), and the only significant impurity measured is H2S in a range of 70–80 ppm. The as-produced biogas has been used for feeding a planar Ni-YSZ anode-supported SOFC with a LSCF cathode. The biogas desulphurization was accomplished flowing the gas in a fixed-bed reactor, filled with activated. The fuel processing with POX has been assessed to avoid carbon deposition into the Ni-YSZ anode and convert the CH4 into H2 and CO. Short tests to check for eventual anode degradation were performed under typical operating conditions. The cell voltage was always stable under load with the tested mixtures. A cell electrical efficiency around 45% has been measured at 800°C and 80% FU. System simulations have performed as well to assess the whole system configuration under a biogas feeding. Optimization routines have been implemented to predict the best net AC efficiency achievable by a SOFC system running on biogas. Additional considerations on the management of poor LHV biogas mixture have been also assessed, showing how dry-reforming of CH4 with the CO2 already available in the biogas stream would be an excellent option needed to be investigated with further detail in the next future.


1993 ◽  
Vol 28 (1) ◽  
pp. 145-148 ◽  
Author(s):  
E. Friedrich ◽  
H. Friedrich ◽  
W. Heinze ◽  
K. Jobst ◽  
H.-J. Richter ◽  
...  

The studies aimed at examining the influences of the particle size distribution and surface charge on the behaviour of sludge in dewatering. It was possible to show that defined size dispersions of sludge particles as well as surface charge are necessary to reach better dewatering results and that the found correlations were independent of the type of sludge and the sewage treatment plant (Friedrich et al., 1990 and 1991). Based on laser diffraction measurements to determine panicle size distribution it was found that it was necessary to set a specific proportion between fine and large sludge particles in order to produce the best possible dewatering results and to get the required shear resistant flocs. To characterize the surface charge of the sludge particles various measuring methods were used. Determining the zeta-potential is a suitable means to describe the kinetics of degradation process in the sludge.


2015 ◽  
Vol 737 ◽  
pp. 635-638
Author(s):  
Ke Zhao ◽  
Zheng Kong

The general existing low temperature problem in winter of north-city sewage treatment plant in the process of waste water treatment seriously affect the efficiency of the work. The research objective of this paper is to conduct investigate in the application of AICS method in Jilin Province, a sewage treatment plant engineering example has been employed to monitor the effluent of the indicators of sewage treatment under the low temperature condition during the winter the winter low temperature under the condition of sewage treatment plant effluent of the indicators; to understand the operation situation of sewage treatment plant, and to study the efficiency of hydrolysis - AICS processing waste-water. The result shows that: hydrolysis - AICS process works well in low temperature condition, the per TN removal rate is 76.79%, average removal rate of NH3 - N is 85.76%, average TP removal rate was 93.4%, the average COD removal rate was 90.6%. The effluent meet the national level A discharge standard requirements of "urban sewage treatment plant pollutant discharge standard". And through the retrenchment of the second pond and other ancillary equipment, Hydrolysis-AICS process could efficiently reduce the costs. Besides, the advantages of Hydrolysis-AICS process also include occupying small area, and operating easily and simply. Therefore Hydrolysis-AICS process is very helpful to achieve the sewage discharging standard in the northern towns.


Sign in / Sign up

Export Citation Format

Share Document