Thermo-hydraulic Performance Investigation of Twisted Tapes Having Teardrop-Shaped Dimple-Protrusion Patterns

Author(s):  
Hakan BUCAK ◽  
Fuat YILMAZ
2020 ◽  
Author(s):  
Li Wang ◽  
Peiyong Ni ◽  
Guannan Xi

Abstract This study is conducted to investigate the effect of off-center placement of twisted tape on flow distribution and heat transfer in a circular tube. The effect of tape width of 20, 18, 16, 14 and 12 mm on the heat transfer performance is discussed under the same twist ratio of 2.0. The numerical analysis of the flow field, average Nusselt number, friction factor and thermo-hydraulic performance parameter of the tube are discussed with Reynolds number ranged from 2600 to 8760. The results indicate that the Nusselt number of the tube fitted with center-placed twisted tapes at various width is 7~51% higher than the plain tube, and performance in low Reynolds region was found more effective than that in high Reynolds region. The heat transfer for circular tube with twisted tape attached to the wall shows better performance than that for the tube with center-placed twisted tape. With a smaller tape width, a higher increasing ratio of Nu-wall/Nu-center is obtained. The increasing ratio for Nusselt number ranged from 3 to 18%. However, the use of twisted tape inserts is not beneficial for energy saving. The thermo-hydraulic performance parameters for convective heat transfer of helium gas flowing in a circular tube are below unity for the calculated Reynolds region.


2018 ◽  
Vol 136 ◽  
pp. 516-530 ◽  
Author(s):  
N. Piriyarungrod ◽  
Manoj Kumar ◽  
C. Thianpong ◽  
M. Pimsarn ◽  
V. Chuwattanakul ◽  
...  

2021 ◽  
Vol 15 ◽  
Author(s):  
Rohit Khargotra ◽  
Raj Kumar ◽  
Rahul Nadda ◽  
Tej Singh

: Turbulence promoters in the form of twisted tapes effectively improve heat exchangers thermal performance. The current review article summarizes the experimental and numerical behaviours of a heat exchanger. The experimental investigation reported in the literature of heat enhancement and fluid flowing characteristics with different twisted tape and tube configurations. Distant twisted tape configurations are employed to increase the heat enhancement rate in the different heat exchanger tubes. Based on the correlations developed by different investigators, an experiment has been made to differentiate the thermal-hydraulic performance of twisted tape configurations in heat exchanger tubes. A comparative study is also carried out to select the excellent twisted tape and tube configurations for superior thermohydraulic performance in the present work. This review article also provides a platform for researchers researching a similar area to design an improved heat enhancement rate apparatus using superlative twisted tape and tube configurations to increase the thermohydraulic performance by increasing the system's energy output.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Li Wang ◽  
Peiyong Ni ◽  
Guannan Xi

AbstractThis study is conducted to investigate the effect of off-center placement of twisted tape on flow distribution and heat transfer in a circular tube. The effect of tape width of 20, 18, 16, 14 and 12 mm on the heat transfer performance is discussed under the same twist ratio of 2.0. The numerical analysis of the flow field, average Nusselt number, friction factor and thermo-hydraulic performance parameter of the tube are discussed with Reynolds number ranged from 2600 to 8760. The results indicate that the Nusselt number of the tube fitted with center-placed twisted tapes at various width is 7–51% higher than the plain tube, and performance in low Reynolds region was found more effective than that in high Reynolds region. The heat transfer for circular tube with twisted tape attached to the wall shows better performance than that for the tube with center-placed twisted tape. With a smaller tape width, a higher increasing ratio of Nu-wall/Nu-center is obtained. The increasing ratio for Nusselt number ranged from 3 to 18%. However, the use of twisted tape inserts is not beneficial for energy saving. The thermo-hydraulic performance parameters for convective heat transfer of helium gas flowing in a circular tube are below unity for the calculated Reynolds region.


Irriga ◽  
2003 ◽  
Vol 8 (1) ◽  
pp. 63-68 ◽  
Author(s):  
Marco Antonio Fonseca Conceição ◽  
Rubens Duarte Coelho

RELAÇÃO VAZÃO x PRESSÃO EM MICROASPERSORES DAN 2001 SOB CONDIÇÃO ADVERSA DE OPERAÇÃO  Marco Antônio Fonseca ConceiçãoEmbrapa Uva e Vinho, Estação Experimental de Jales, Jales, SP. CP 241. CEP 15700-000.E-mail: [email protected] Duarte CoelhoDepartamento de Engenharia Rural, Escola Superior de Agricultura “Luiz de Queiroz”, Universidade de São Paulo, Piracicaba, SP. CP 09, CEP 13418-900.E-mail: [email protected]  1 RESUMO  Alguns microaspersores possuem membranas que regulam a sua pressão de operação, mantendo a vazão praticamente estável dentro de uma faixa de pressão na rede hidráulica. Operadores de irrigação no campo, muitas vezes com baixo nível de instrução e sem orientação profissional qualificada, visando reduzir problemas de entupimento ou para diminuir o tempo de irrigação, costumam retirar as membranas autocompensantes para aumentar a vazão do emissores, o que pode comprometer o desempenho hidráulico do sistema. Para avaliar o efeito da retirada da membrana  sobre as vazões dos microaspersores, no presente trabalho determinou-se as relações entre pressão e vazão para sete bocais do microaspersor DAN 2001, operando na ausência da membrana autocompensante. As curvas pressão-vazão sem as membranas autocompensantes apresentaram comportamento potencial com expoentes variando entre 0,58 e 0,64. As vazões dos microaspersores sem as membranas aumentaram de forma inversamente proporcional aos diâmetros dos emissores, quando comparadas às vazões nominais com as membranas.  UNITERMOS: Hidráulica, irrigação, microaspersão.  CONCEIÇÃO, M.A.F.; COELHO, R.D. FLOW X PRESSURE RELATIONSHIP FOR DAN 2001 MICROSPRINKLERS UNDER ADVERSE CONDITION  2 ABSTRACT  Many types of microsprinklers have a self-compensating membrane to regulate their pressure, keeping a stable flow. Many producers usually take the membranes off to reduce clogging problems  or irrigation time. This procedure could endanger the system hydraulic performance. To evaluate the effect of taking off the self-compensating membrane from microsprinklers it was determined, in the present work, the pressure-flow relationship for seven Dan 2001 microsprinkler nozzles operating without the membrane. The pressure-flow curves presented a potential behavior with the exponents varying from 0.58 to 0.64. Microsprinkler flows without the membranes increased inversely proportional to the emitter diameters, comparing to the nominal flows using the membranes.  KEYWORDS: Hydraulic, irrigation, microsprinkler.


Sign in / Sign up

Export Citation Format

Share Document