Shear wave versus strain elastography of breast lesions—The value of incorporating boundary tissue assessment

2022 ◽  
Vol 82 ◽  
pp. 228-233
Author(s):  
Ian Wei Ming Tay ◽  
Llewellyn Shao-jen Sim ◽  
Tammy Hui Lin Moey ◽  
Karen Pei Pei Tan ◽  
Lily Mei San Lai ◽  
...  
2019 ◽  
Vol 49 (5) ◽  
pp. 1509-1517 ◽  
Author(s):  
Aykut GÜRÜF ◽  
Mesut ÖZTÜRK ◽  
İlkay Koray BAYRAK ◽  
Ahmet Veysel POLAT

2020 ◽  
Vol 148 (9) ◽  
pp. 1239-1245
Author(s):  
Huiwen Jiang ◽  
Xiaodan Yu ◽  
Lina Zhang ◽  
Linxiao Song ◽  
Xiuhua Gao

Author(s):  
Vito Cantisani ◽  
Emanuele David ◽  
Richard G. Barr ◽  
Maija Radzina ◽  
Valeria de Soccio ◽  
...  

Abstract Purpose To evaluate the diagnostic performance of strain elastography (SE) and 2 D shear wave elastography (SWE) and SE/SWE combination in comparison with conventional multiparametric ultrasound (US) with respect to improving BI-RADS classification results and differentiating benign and malignant breast lesions using a qualitative and quantitative assessment. Materials and Methods In this prospective study, 130 histologically proven breast masses were evaluated with baseline US, color Doppler ultrasound (CDUS), SE and SWE (Toshiba Aplio 500 with a 7–15 MHz wide-band linear transducer). Each lesion was classified according to the BIRADS lexicon by evaluating the size, the B-mode and color Doppler features, the SE qualitative (point color scale) and SE semi-quantitative (strain ratio) methods, and quantitative SWE. Histological results were compared with BIRADS, strain ratio (SR) and shear wave elastography (SWE) all performed by one investigator blinded to the clinical examination and mammographic results at the time of the US examination. The area under the ROC curve (AUC) was calculated to evaluate the diagnostic performance of B-mode US, SE, SWE, and their combination. Results Histological examination revealed 47 benign and 83 malignant breast lesions. The accuracy of SR was statistically significantly higher than SWE (sensitivity, specificity and AUC were 89.2 %, 76.6 % and 0.83 for SR and 72.3 %, 66.0 % and 0.69 for SWE, respectively, p = 0.003) but not higher than B-mode US (B-mode US sensitivity, specificity and AUC were 85.5 %, 78.8 %, 0.821, respectively, p = 1.000). Conclusion Our experience suggests that conventional US in combination with both SE and SWE is a valid tool that can be useful in the clinical setting, can improve BIRADS category assessment and may help in the differentiation of benign from malignant breast lesions, with SE having higher accuracy than SWE.


Diagnostics ◽  
2021 ◽  
Vol 11 (6) ◽  
pp. 1015
Author(s):  
Antonio Bulum ◽  
Gordana Ivanac ◽  
Eugen Divjak ◽  
Iva Biondić Špoljar ◽  
Martina Džoić Dominković ◽  
...  

Shear wave elastography (SWE) is a type of ultrasound elastography with which the elastic properties of breast tissues can be quantitatively assessed. The purpose of this study was to determine the impact of different regions of interest (ROI) and lesion size on the performance of SWE in differentiating malignant breast lesions. The study included 150 female patients with histopathologically confirmed malignant breast lesions. Minimal (Emin), mean (Emean), maximal (Emax) elastic modulus and elasticity ratio (e-ratio) values were measured using a circular ROI size of 2, 4 and 6 mm diameters and the lesions were divided into large (diameter ≥ 15 mm) and small (diameter < 15 mm). Highest Emin, Emean and e-ratio values and lowest variability were observed when using the 2 mm ROI. Emax values did not differ between different ROI sizes. Larger lesions had significantly higher Emean and Emax values, but there was no difference in e-ratio values between lesions of different sizes. In conclusion, when measuring the Emin, Emean and e-ratio of malignant breast lesions using SWE the smallest possible ROI size should be used regardless of lesion size. ROI size has no impact on Emax values while lesion size has no impact on e-ratio values.


2018 ◽  
Vol 60 (1) ◽  
pp. 28-34
Author(s):  
Jin Hee Moon ◽  
Sung Hye Koh ◽  
Sun-Young Park ◽  
Ji-Young Hwang ◽  
Ji Young Woo

Background The maximum value of the strain ratio (SR) is a newly developed measure in strain-elastography. Purpose To prospectively compare the diagnostic performance of three different measures of strain-elastography, the maximum value of the SR (SRmax), the average value of the SR (SRave), and the color map, for differentiating benign and malignant breast lesions. Material and Methods We obtained the SRmax and SRave of 314 lesions from 290 patients with the tissue to nodule SR and color map using a five-degree scoring system. The diagnostic performances of the SRmax, SRave, and color map were compared after obtaining the area under the receiver operating characteristic (ROC) curves (AUCs) of each parameter. Results The AUC of the SRmax (0.7674) was larger than the AUCs of the SRave (0.7138) and color map (0.6324), with statistical significance ( P = 0.0383 for SRmax vs. SRave, P = 0.0000 for SRmax vs. color map). The AUC of the SRave was larger than that of the color map; however, there was no significant difference. The optimal cut-off point of the SRmax that balanced the sensitivity (91.12%) and specificity (50.81%) was 5.16. Conclusion The SRmax is a more reliable diagnostic tool than the SRave and color map for differentiating benign and malignant breast lesions.


Sign in / Sign up

Export Citation Format

Share Document