Assessment of geometrical and seasonal effects on the natural ventilation of a pig barn using CFD simulations

2022 ◽  
Vol 193 ◽  
pp. 106652
Author(s):  
Marco Bovo ◽  
Enrica Santolini ◽  
Alberto Barbaresi ◽  
Patrizia Tassinari ◽  
Daniele Torreggiani
Energies ◽  
2021 ◽  
Vol 14 (8) ◽  
pp. 2197
Author(s):  
Nayara Rodrigues Marques Sakiyama ◽  
Jurgen Frick ◽  
Timea Bejat ◽  
Harald Garrecht

Predicting building air change rates is a challenge for designers seeking to deal with natural ventilation, a more and more popular passive strategy. Among the methods available for this task, computational fluid dynamics (CFD) appears the most compelling, in ascending use. However, CFD simulations require a range of settings and skills that inhibit its wide application. With the primary goal of providing a pragmatic CFD application to promote wind-driven ventilation assessments at the design phase, this paper presents a study that investigates natural ventilation integrating 3D parametric modeling and CFD. From pre- to post-processing, the workflow addresses all simulation steps: geometry and weather definition, including incident wind directions, a model set up, control, results’ edition, and visualization. Both indoor air velocities and air change rates (ACH) were calculated within the procedure, which used a test house and air measurements as a reference. The study explores alternatives in the 3D design platform’s frame to display and compute ACH and parametrically generate surfaces where air velocities are computed. The paper also discusses the effectiveness of the reference building’s natural ventilation by analyzing the CFD outputs. The proposed approach assists the practical use of CFD by designers, providing detailed information about the numerical model, as well as enabling the means to generate the cases, visualize, and post-process the results.


2016 ◽  
Vol 78 (8-4) ◽  
Author(s):  
Fawaz Ghaleb Noman ◽  
Nazri Kamsah ◽  
Haslinda Mohamed Kamar

A combined natural ventilation and mechanical fans are commonly used to cool the interior space inside the mosques in Malaysia. This article presents a study on thermal comfort in the Al-Jawahir Mosque, located in Johor Bahru, Malaysia. The objective is to assess the thermal comfort inside the mosque under the present ventilation system by determining the Predicted Mean Vote (PMV) and the Predicted Percentage of Dissatisfied (PPD). These values were then compared to the limits stated in the ASHRAE Standard-55. It was found that the PMV varies from 1.68 to 2.26 while the PPD varies from 61% to 87%. These show that the condition inside the mosque is quite warm. Computational fluid dynamics (CFD) method was used to carry out flow simulations, to identify a suitable strategy to improve the thermal comfort inside the mosque. Results of CFD simulations show that installing four exhaust fans above the windows on the west-side wall of the mosque is the most effective strategy to improve the thermal comfort inside the mosque. Both the PMV and PPD values can potentially be reduced by more than 60%.


2019 ◽  
Vol 63 (3) ◽  
pp. 201-206
Author(s):  
Zuzana Straková ◽  
Jozef Vojtaššák ◽  
Peter Beňovský ◽  
Daniela Koudelková

The aim of this study is to design industrial ventilation in the production hall. With respect to the many parameters which influence the appropriate proposal of industrial ventilation that need to be considered, there is a good chance for miscalculations when design the industrial ventilation. Especially when the heat loads from technology threaten the stability of construction of the building. There are two different ways of solution of aeration in the aluminium plant. There is only a natural ventilation using outside air in case of melting of aluminium and an adiabatic cooling for air inlet combined with natural ventilation. The results and practice has shown, that to use only an outside air is not sufficient and the temperature in the hall is really very high. Adiabatic cooling decreases the air inlet temperature in the production hall and improves the working conditions. A thermovision mapping of the technology was used prior to start the CFD modelling. The simulation emphasize the important effect of design and location of different elements on the functionality of ventilation proposal.


2016 ◽  
Vol 125 ◽  
pp. 276-286 ◽  
Author(s):  
Stefano Benni ◽  
Patrizia Tassinari ◽  
Filippo Bonora ◽  
Alberto Barbaresi ◽  
Daniele Torreggiani

2013 ◽  
Vol 421 ◽  
pp. 844-849
Author(s):  
An Shik Yang ◽  
Chao Jui Chang ◽  
Yu Hsuan Juan ◽  
Ying Ming Su

The goal of this investigation is to conduct the CFD analysis in conjunction with the wind comfort level standard to predict the pedestrian wind comfort level around the Dreams, Angel Life and Future pavilions in the Xinsheng Park of the Taipei International Flora Exposition. The computerized airflow simulations were carried out to predict the detailed flowfield for determining the comfort level of outdoor wind environment for three pavilions in the Xinsheng Park. In order to generate the suitable environments of natural ventilation for visitors, the calculated results can be used to appraise the sufficiency of natural ventilation for the open space around the building cluster.


2006 ◽  
Vol 12 (2) ◽  
pp. 257-278 ◽  
Author(s):  
Lina Yang ◽  
Yuguo Li ◽  
Pengcheng Xu ◽  
Guoqiang Zhang

2021 ◽  
Vol 11 (2) ◽  
pp. 72-81
Author(s):  
Sandra Rodríguez-Trejo ◽  
Víctor Fuentes-Freixanet

In recent years, energy consumption from electrical devices to foster air movement in regions with warm climates has risen, with the resulting negative impact on the environment. The purpose of this paper is to evaluate the performance of a solar chimney used to induce natural ventilation in a closed space, under the weather conditions of the hot humid Mexican climate. For this purpose, CFD simulations were run using the RNG k- ɛ turbulence model and the DO radiation model, considering only natural convection phenomena. The solar chimney performance was evaluated, comparing the results of the simulations with experimental measurements, analysis which showed a good match. Temperatures of up to 46.5%°C in the air within the chimney, and of 77.1°C on the absorption plate, were obtained, results that allow verifying the influence of the heat discharge phenomenon by the natural flotation of air in the chimney.


2006 ◽  
Vol 5 (1) ◽  
pp. 13-20 ◽  
Author(s):  
Nigel G. Wright ◽  
David M. Hargreaves