The effect of blockage and tunnel slope on smoke spread and ceiling temperature distribution in a natural-ventilated metro depot

2021 ◽  
pp. 111540
Author(s):  
Jiaqiang Han ◽  
Zihao Wang ◽  
Pengqiang Geng ◽  
Fei Wang ◽  
Jennifer Wen ◽  
...  
Energies ◽  
2020 ◽  
Vol 13 (7) ◽  
pp. 1826
Author(s):  
Bei Cao ◽  
Xiaodong Zhou ◽  
Yubiao Huang ◽  
Yuan Zheng ◽  
Kai Ye ◽  
...  

Fire-induced thermal flow is the greatest threat to trapped people and the heat-resistant quality of building structures. This paper presents an experimental investigation of the effects of external wind on the ceiling temperature distribution of fire-induced thermal flow in a one-sixth scale corridor connected to a compartment. In the experiments, the fire source was placed in the compartment with hot thermal flow spilled into the connected corridor. The heat release rate (HRR) was changed from 10 to 20 kW and the external wind velocity was changed from 0 to 2.09 m/s. The ends of the corridor could be adjusted to be fully or partially open to the environment with dam-boards arranged at the ends of the corridor. An effective corridor HRR, Qcorridor, was defined to account for the amount of the spilled plume into the corridor. Results show that the temperature under the ceiling changed in a non-monotonic way with wind velocity: it first increased and then decreased with wind velocity. It was revealed that the dam-boards at the corridor opening had an evidently shielding effect, leading to higher temperature compared to the fully open environment. Finally, uniform correlations are proposed for predicting the attenuation law of ceiling temperature profiles in corridors for different wind conditions.


Energies ◽  
2019 ◽  
Vol 12 (8) ◽  
pp. 1411 ◽  
Author(s):  
Peng Zhao ◽  
Zhongyuan Yuan ◽  
Yanping Yuan ◽  
Nanyang Yu ◽  
Tao Yu

Smoke control is a crucial issue in a long-distance subway tunnel fire, and a two-point extraction ventilation system is an effective way to solve this problem, due to the characteristics of controlling the smoke in a limited area and removing high-temperature and toxic smoke in time. In this study, the ceiling temperature distribution and the critical exhaust volumetric flow rate to control the smoke in the zone between two extraction vents were investigated in a long-distance subway tunnel fire with a two-point extraction ventilation system. Experiments were carried out in a 1/20 reduced-scale tunnel model based on Froude modeling. Factors, including the heat release rate (HRR), the extraction vent length, the internal distance between two extraction vents and exhaust volumetric flow rate, were studied. Smoke temperature below the ceiling, exhaust volumetric flow rate and smoke spreading configurations were measured. The ceiling temperature distribution was analyzed. Meanwhile, an empirical equation was developed to predict the critical exhaust volumetric flow rate based on the one-dimensional theory, experimental phenomenon and the analysis of forces acting at the smoke underneath the extraction vent. The coefficients in the empirical equation were determined by experimental data. Compared with the experimental results, the developed empirical equation can predict the critical exhaust volumetric flow rate well. Research outcomes in this study will be beneficial to the design and application of two-point extraction ventilation system for a long-distance subway tunnel fire.


2007 ◽  
Vol 26 (4) ◽  
pp. 473-478
Author(s):  
Hiroyuki Sunahara ◽  
Takahiro Ishihara ◽  
Akimitsu Kikkawa ◽  
Masayuki Mizuno ◽  
Yoshifumi Ohmiya ◽  
...  

2020 ◽  
Vol 194 ◽  
pp. 05061
Author(s):  
GENG Pengqiang ◽  
WANG Zihao ◽  
WENG Miaocheng ◽  
LIU Fang

.This paper uses Fire Dynamics Simulator (FDS) to study the effect of the longitudinal distance from the shaft to the fire source on the natural smoke exhaust of the tunnel fire with one closed portal, and analyzes the temperature distribution of the smoke and the shaft’s smoke exhaust efficiency. The results show that when the shaft is located downstream of the fire source (Ds<0), with the increase of the distance from the shaft to the fire source, the smoke exhaust efficiency decreases first and then stabilizes at a fixed value. At this time, the ceiling temperature attenuation’s coefficient at upstream of the fire source is only related to the heat release rate of the fire source (HRR). When the shaft is located upstream of the fire source (Ds>0), the smoke exhaust efficiency increases slightly with the increase of the distance from the shaft to the fire source, but the overall value is relatively small. When HRR is fixed, the shaft located downstream of the fire source has a higher smoke exhaust efficiency. As the distance between the shaft and the fire source increases, the plug phenomenon decreases.


2019 ◽  
Vol 14 ◽  
pp. 100453 ◽  
Author(s):  
Zhen-huan Liang ◽  
Guo-qing Zhu ◽  
Hao-nan Liu ◽  
Xiang Zhou