Thermal design of a humidification-dehumidification desalination cycle consisting of packed-bed humidifier and finned-tube dehumidifier

Author(s):  
Kapil Garg ◽  
Sarit K. Das ◽  
Himanshu Tyagi
Author(s):  
Amit Dhingra ◽  
Hong G. Im ◽  
Sujit Srinivas ◽  
Erdogan Gulari

Recent advances in PEM fuel cell systems have demonstrated their role in the production of clean and efficient power. However, due to complexities and safety concerns in the storage and transport of hydrogen, development of on-board fuel processing of hydrocarbon into hydrogen is being considered a critical issue in the success of the fuel cell technology in transportation application. In this paper, a novel concept of scalable silicon micro-reactor with an integrated platinum heater is developed for preferential CO oxidation. The performance of the micro-reactor is assessed and compared to a packed-bed reactor model. Complementary experimental and modeling efforts are made to identify the optimal thermal design parameters. It is demonstrated that the silicon micro-reactors successfully achieves the objectives of scalability without suffering from loss of efficiency due to the mass transfer limitations.


2020 ◽  
Vol 45 (46) ◽  
pp. 25109-25121
Author(s):  
Yueyue Shi ◽  
Yongqi Liu ◽  
Yuqi Zhou ◽  
Peng Sun ◽  
Mingming Mao ◽  
...  

1988 ◽  
Vol 2 (6) ◽  
pp. 303
Author(s):  
K.J.H. Hacke
Keyword(s):  

TAPPI Journal ◽  
2016 ◽  
Vol 15 (4) ◽  
pp. 265-272 ◽  
Author(s):  
ROHAN BANDEKAR ◽  
JIM FREDERICK ◽  
JAROSLAV STAVIK

This study addresses the challenges a dissolving-grade pulp mill in Canada faced in 2014 in meeting its total reduced sulfur (TRS) gas emission limit. These emissions from the recovery boiler exit are controlled by passing the boiler exit gas through a TRS scrubber system. The mill employs a cyclonic direct contact evaporator to concentrate black liquor to firing solids content. The off-gases from the direct contact evaporator flow to the effluent gas control system that consists of a venturi scrubber, a packed bed scrubber, and a heat recovery unit. Emissions of TRS greater than the regulated limit of 15 ppm were observed for a 4-month period in 2014. The level of emissions measured during this period was significantly higher than about 12 ppm, the expected average value based on historic experience. The problem persisted from mid-June 2014 until the annual mill shutdown in October 2014. The main TRS components detected and the performance of the Teller scrubber in capturing them are examined. Other potential causes for these emissions are identified, including mechanical problems such as broken packing in the TRS packed bed scrubber, broken baffle plates in the scrubber, and cyclone evaporator leaks causing air ingress. Repairs were carried out during the mill shutdown, which eliminated the TRS emissions problem.


2019 ◽  
Vol 5 (1) ◽  
pp. 27-33
Author(s):  
Mostafa Sharqawy ◽  
◽  
Robert Zinni

2015 ◽  
Vol 135 (7) ◽  
pp. 435-436 ◽  
Author(s):  
Kazuhiro Takahashi ◽  
Kohki Satoh ◽  
Hidenori Itoh ◽  
ichi Itakura

2012 ◽  
Vol 132 (3) ◽  
pp. 53-57
Author(s):  
Yuya Shiokawa ◽  
Tatsuya Nakano ◽  
Naoki Maeda ◽  
Masafumi Kimata ◽  
Akihiro Takahata

Sign in / Sign up