Improved tensile membrane action model of composite slabs at elevated temperatures

Structures ◽  
2022 ◽  
Vol 36 ◽  
pp. 13-31
Author(s):  
Hong-hui Qi ◽  
Yong Du ◽  
Jian Jiang ◽  
Guo-qiang Li
Author(s):  
Ali Alskeif ◽  
Ian W. Burgess ◽  
Shan-Shan Huang

<p>The mechanics of tensile membrane action of thinlightly-reinforced concrete slabs has been re-examined during the last two years.The re-examination is based on large-deflection plastic yield-line analysis, applied to flat slabs. As deflection increases beyond the optimum yield-line pattern, tensile membrane action is mobilized and further load carrying capacity is provided. This paper represents an extension of this re-examination to include composite slabs at high temperatures. As temperature increases, the unprotected downstand steel beams significantly lose capacity, allowing for further deflection until the overall capacity degrades to the applied load. Tensile membrane action then allows further increase of steel temperature until a maximum is reached.</p>


2016 ◽  
Vol 20 (10) ◽  
pp. 1451-1465 ◽  
Author(s):  
Shou-Chao Jiang ◽  
Gianluca Ranzi ◽  
Ling-Zhu Chen ◽  
Guo-Qiang Li

This article presents an extensive experimental and numerical study aimed at the evaluation of the thermo-structural response of composite beams with composite slabs. Two full-scale fire tests were carried out on simply supported composite steel-concrete beams with steel sheeting perpendicular and parallel to the steel joist, respectively. Both specimens were observed to fail by developing large displacements. Concrete crushing at the mid-span, debonding of the profiled sheeting and spalling of the fire protection were observed during both tests. A three-dimensional finite element model was developed in ABAQUS, and its accuracy was validated against the experimental measurements collected as part of this study. The model was then used to perform a parametric study to determine the influence of the degree of shear connection, load ratio and design fire rate on the structural response of composite beams at elevated temperatures. These results, together with experimental data available in the literature, were used to evaluate the ability of European guidelines to predict the critical temperature of composite beams. It was shown that predictions from Eurocode 4 were safe and provided conservative estimates for most cases.


2018 ◽  
Vol 9 (1) ◽  
pp. 77-90 ◽  
Author(s):  
Lorenzo Lelli ◽  
Jonas Loutan

Purpose This paper aims to detail the advanced natural fire simulations that were carried out for the composite steel-reinforced concrete structure of the JTI Building in Geneva, Switzerland. The results of these analyses led to a significant reduction of in the fireproofing of the steel floor framing. Design/methodology/approach Several scenarios were studied considering different thermal behaviours of the peripheral cladding. Despite the small thickness of the resisting slabs, the analyses performed with SAFIR software showed that the typical wide storey bay (12 × 15.86 m) can resist to the design’s fire temperatures without the protection of the main and secondary beams while the spandrels remain protected. For study completeness, the composite frame-membrane model was also simulated with Hasemi-localized fire routines on SAFIR. Findings The analyses have showed that the membrane behaviour of composite slabs under fire allows a significant reduction of the fire protection, even in case of small thickness of the concrete topping. The increase of the reinforcement ratio to sustain the membrane forces is widely compensated by the savings related to the fireproofing of the steel framing. Practical/implications A natural fire approach is particularly advisable in case of fully glazed buildings. In fact when the façade collapses, the entry of a large cold air quantity limits the increase of the gas temperature inside the compartment. Originality/value The analyses were carried out with recent SAFIR routines for localized fires (Hasemi fire model) and represent one of the first applications in practice. The issue of the rebar orientation in mesh is raised out. The latest SAFIR release allows the definition of a global orientation of the rebars and amends the issue.


2015 ◽  
Vol 115 ◽  
pp. 387-397 ◽  
Author(s):  
Ling-Zhu Chen ◽  
Gianluca Ranzi ◽  
Shou-Chao Jiang ◽  
Faham Tahmasebinia ◽  
Guo-Qiang Li

Author(s):  
N. M. P. Low ◽  
L. E. Brosselard

There has been considerable interest over the past several years in materials capable of converting infrared radiation to visible light by means of sequential excitation in two or more steps. Several rare-earth trifluorides (LaF3, YF3, GdF3, and LuF3) containing a small amount of other trivalent rare-earth ions (Yb3+ and Er3+, or Ho3+, or Tm3+) have been found to exhibit such phenomenon. The methods of preparation of these rare-earth fluorides in the crystalline solid form generally involve a co-precipitation process and a subsequent solid state reaction at elevated temperatures. This investigation was undertaken to examine the morphological features of both the precipitated and the thermally treated fluoride powders by both transmission and scanning electron microscopy.Rare-earth oxides of stoichiometric composition were dissolved in nitric acid and the mixed rare-earth fluoride was then coprecipitated out as fine granules by the addition of excess hydrofluoric acid. The precipitated rare-earth fluorides were washed with water, separated from the aqueous solution, and oven-dried.


Author(s):  
J. L. Brimhall ◽  
H. E. Kissinger ◽  
B. Mastel

Some information on the size and density of voids that develop in several high purity metals and alloys during irradiation with neutrons at elevated temperatures has been reported as a function of irradiation parameters. An area of particular interest is the nucleation and early growth stage of voids. It is the purpose of this paper to describe the microstructure in high purity nickel after irradiation to a very low but constant neutron exposure at three different temperatures.Annealed specimens of 99-997% pure nickel in the form of foils 75μ thick were irradiated in a capsule to a total fluence of 2.2 × 1019 n/cm2 (E > 1.0 MeV). The capsule consisted of three temperature zones maintained by heaters and monitored by thermocouples at 350, 400, and 450°C, respectively. The temperature was automatically dropped to 60°C while the reactor was down.


Author(s):  
Robert C. Rau ◽  
Robert L. Ladd

Recent studies have shown the presence of voids in several face-centered cubic metals after neutron irradiation at elevated temperatures. These voids were found when the irradiation temperature was above 0.3 Tm where Tm is the absolute melting point, and were ascribed to the agglomeration of lattice vacancies resulting from fast neutron generated displacement cascades. The present paper reports the existence of similar voids in the body-centered cubic metals tungsten and molybdenum.


Sign in / Sign up

Export Citation Format

Share Document