Understanding the electrode polarization in bismuth zinc vanadate semiconducting glasses from dielectric spectroscopy: A new insight on electrode polarization effect

2021 ◽  
Vol 574 ◽  
pp. 121174
Author(s):  
R. Punia ◽  
Sajjan Dahiya ◽  
S. Murugavel ◽  
N. Kishore ◽  
R.P. Tandon
2019 ◽  
Vol 21 (2) ◽  
pp. 681-691 ◽  
Author(s):  
Zahra Ghobaei Namhil ◽  
Cordula Kemp ◽  
Emanuele Verrelli ◽  
Alex Iles ◽  
Nicole Pamme ◽  
...  

A significant impediment to the use of impedance spectroscopy in bio-sensing is the electrode polarization effect that arises from the movement of free ions to the electrode–solution interface, forming an electrical double layer (EDL).


2001 ◽  
Vol 12 (8) ◽  
pp. 1355-1364 ◽  
Author(s):  
Yu Feldman ◽  
E Polygalov ◽  
I Ermolina ◽  
Yu Polevaya ◽  
B Tsentsiper

2011 ◽  
Vol 83 (2) ◽  
pp. 157-165 ◽  
Author(s):  
S. Emmert ◽  
M. Wolf ◽  
R. Gulich ◽  
S. Krohns ◽  
S. Kastner ◽  
...  

Author(s):  
Shide Bakhtiari ◽  
Mohammad K. D. Manshadi ◽  
Amin Mansoorifar ◽  
Ali Beskok

Dielectric spectroscopy (DS) is a promising cell screening method that can be used for diagnostic and drug discovery purposes. The primary challenge of using DS in physiological buffers is the electrode polarization (EP) that overwhelms the impedance signal within a large frequency range. These effects further amplify with miniaturization of the measurement electrodes. In this study, we present a microfluidic system and the associated equivalent circuit models for real-time measurements of cell membrane capacitance and cytoplasm resistance in physiological buffers with 10s increments. The current device captures several hundreds of biological cells in individual microwells through gravitational settling and measures the system’s impedance using microelectrodes covered with dendritic gold nanostructures. Using PC-3 cells (a highly metastatic prostate cancer cell line) suspended in cell growth media (CGM), we demonstrate stable measurements of cell membrane capacitance and cytoplasm resistance in the device for over 15 minutes. We also describe a consistent application of the equivalent circuit model, starting from the reference measurements used to determine the system parameters. The circuit model is tested using devices with varying dimensions, and the obtained cell parameters between different devices are nearly identical. Further analyses of the impedance data have shown that accurate cell membrane capacitance and cytoplasm resistance can be extracted using a limited number of measurements in the 5 MHz to 10 MHz range. This will potentially reduce the timescale required for real-time DS measurements below 1s. Overall the new microfluidic device can be used for dielectric characterization of biological cells in physiological buffers for various cell screening applications.