Measurement of neutron production from an 18O target

Author(s):  
P.Z. Ngcobo ◽  
R.A. Bark ◽  
A. Buffler ◽  
P. Papka ◽  
D.R. Geduld ◽  
...  
Keyword(s):  
2021 ◽  
pp. 1-16
Author(s):  
Paul Zakalek ◽  
Jingjing Li ◽  
Sarah Böhm ◽  
Ulrich Rücker ◽  
Jörg Voigt ◽  
...  

Compact accelerator-driven neutron sources allow to operate multiple optimised target-moderator-reflector (TMR) units adapted to the requirements of the respective instruments. The compact design of the TMR units allows an efficient coupling of neutron production, neutron moderation and extraction, but requires a novel way of optimisation. The neutronic performance of different TMR units based on polyethylene, heavy water and a mixture of heavy and light water moderators together with Pb and Be reflectors and a borated polyethylene absorber is discussed. Extraction channels for thermal and cold neutrons are investigated regarding the energy and time spectra.


2021 ◽  
Vol 882 ◽  
pp. 115024
Author(s):  
Phillip J. Smith ◽  
Robert C. Hendricks ◽  
Bruce M. Steinetz
Keyword(s):  

Energies ◽  
2021 ◽  
Vol 14 (13) ◽  
pp. 4020
Author(s):  
Peng Sun ◽  
Yiping Lu ◽  
Jianfei Tong ◽  
Youlian Lu ◽  
Tianjiao Liang ◽  
...  

In order to provide a theoretical basis for the thermal design of the neutron production target, flow and heat transfer characteristics are studied by using numerical simulations and experiments. A rectangular mini-channel experimental model consistent with the geometric shape of the heat dissipation structure of neutron production target was established, in which the aspect ratio and gap thickness of the test channel were 53.8:1 and 1.3 mm, respectively. The experimental results indicate that the critical Re of the mini-channel is between 3500 and 4000, and when Re reaches 21,000, Nu can reach 160. The simulation results are in good agreement with the experimental data, and the numerical simulation method can be used for the variable structure optimization design of the target in the later stage. The relationship between the flow pressure drop of the target mini-channel and the aspect ratio and Re is obtained by numerical simulation. The maximum deviation between the correlation and the experimental value is 6%.


1972 ◽  
Vol 100 (1) ◽  
pp. 135-139 ◽  
Author(s):  
G.J. Batra ◽  
D.K. Bewley ◽  
M.A. Chaudhri

Nature ◽  
1958 ◽  
Vol 181 (4604) ◽  
pp. 226-228 ◽  
Author(s):  
D. C. HAGERMAN ◽  
J. W. MATHER

2004 ◽  
Vol 98 (6) ◽  
pp. 1133-1137 ◽  
Author(s):  
V. S. Belyaev ◽  
V. I. Vinogradov ◽  
A. S. Kurilov ◽  
A. P. Matafonov ◽  
V. P. Andrianov ◽  
...  

Author(s):  
D. R. Welch ◽  
R. E. Clark ◽  
D. V Rose ◽  
W. A. Stygar ◽  
R. J. Leeper
Keyword(s):  

Sign in / Sign up

Export Citation Format

Share Document