scholarly journals Using existing infrastructures of high-speed railways for photovoltaic electricity generation

2022 ◽  
Vol 178 ◽  
pp. 106091
Author(s):  
Zhujun Chen ◽  
Mingkun Jiang ◽  
Lingfei Qi ◽  
Wu Wei ◽  
Ziyi Yu ◽  
...  
Author(s):  
Miroslav P. Petrov

High-speed alternators are believed to be well developed nowadays, following the improvement in performance and decrease of costs for electronic power converters and permanent magnet materials. Their compact design and their ability to vary the rotational speed in off-design conditions promise superior performance when compared to conventional generators. High-speed alternators are only available in limited sizes for small-scale applications, whereas improvements in efficiency and optimized part-load behavior are particularly important especially for small-scale electricity generation. Enhanced energy utilization for electricity production by small utility plants or by distributed units located at private homes or commercial buildings, based on thermodynamic cycles powered by natural gas or various renewable energy sources, is possible to be achieved through a wider application of grid-integrated high-speed technology. This study presents a critical review of previous research and demonstration work on high-speed electrical machines and a summary of the technical challenges limiting their performance and their expansion into larger sizes. Conclusions are drawn for finding appropriate solutions for practical high-speed electricity generation units and their readiness for a much wider deployment. Closer analysis is attempted on the thermal and mechanical integrity of high-speed alternators and the technical challenges that slow down their scale-up to MW-size units for utility applications. The necessary research and development work that needs to be done in the near future is outlined and discussed herein.


2021 ◽  
Vol 4 (1) ◽  
pp. 38-44
Author(s):  
András Nagy ◽  
István Jankovics ◽  
Márton Máté

Abstract The aim of this paper is to present the applicability of one of the promising achievements in the fields of materials science and mechanical engineering, which provides a solution to one of the problems of the new generation power plants. One promising area of research aimed at increasing the efficiency of electricity generation is discussed in this article on the characteristics of super-critical carbon dioxide power plant cycles and the properties of high-speed generators that can be used in such power plants. The applicability of amorphous materials in the construction of high-speed electrical machines can solve the efficiency problem of such machines, enabling its use in new generation power plants.


Author(s):  
E.D. Wolf

Most microelectronics devices and circuits operate faster, consume less power, execute more functions and cost less per circuit function when the feature-sizes internal to the devices and circuits are made smaller. This is part of the stimulus for the Very High-Speed Integrated Circuits (VHSIC) program. There is also a need for smaller, more sensitive sensors in a wide range of disciplines that includes electrochemistry, neurophysiology and ultra-high pressure solid state research. There is often fundamental new science (and sometimes new technology) to be revealed (and used) when a basic parameter such as size is extended to new dimensions, as is evident at the two extremes of smallness and largeness, high energy particle physics and cosmology, respectively. However, there is also a very important intermediate domain of size that spans from the diameter of a small cluster of atoms up to near one micrometer which may also have just as profound effects on society as “big” physics.


Author(s):  
N. Yoshimura ◽  
K. Shirota ◽  
T. Etoh

One of the most important requirements for a high-performance EM, especially an analytical EM using a fine beam probe, is to prevent specimen contamination by providing a clean high vacuum in the vicinity of the specimen. However, in almost all commercial EMs, the pressure in the vicinity of the specimen under observation is usually more than ten times higher than the pressure measured at the punping line. The EM column inevitably requires the use of greased Viton O-rings for fine movement, and specimens and films need to be exchanged frequently and several attachments may also be exchanged. For these reasons, a high speed pumping system, as well as a clean vacuum system, is now required. A newly developed electron microscope, the JEM-100CX features clean high vacuum in the vicinity of the specimen, realized by the use of a CASCADE type diffusion pump system which has been essentially improved over its predeces- sorD employed on the JEM-100C.


Author(s):  
William Krakow

In the past few years on-line digital television frame store devices coupled to computers have been employed to attempt to measure the microscope parameters of defocus and astigmatism. The ultimate goal of such tasks is to fully adjust the operating parameters of the microscope and obtain an optimum image for viewing in terms of its information content. The initial approach to this problem, for high resolution TEM imaging, was to obtain the power spectrum from the Fourier transform of an image, find the contrast transfer function oscillation maxima, and subsequently correct the image. This technique requires a fast computer, a direct memory access device and even an array processor to accomplish these tasks on limited size arrays in a few seconds per image. It is not clear that the power spectrum could be used for more than defocus correction since the correction of astigmatism is a formidable problem of pattern recognition.


Author(s):  
C. O. Jung ◽  
S. J. Krause ◽  
S.R. Wilson

Silicon-on-insulator (SOI) structures have excellent potential for future use in radiation hardened and high speed integrated circuits. For device fabrication in SOI material a high quality superficial Si layer above a buried oxide layer is required. Recently, Celler et al. reported that post-implantation annealing of oxygen implanted SOI at very high temperatures would eliminate virtually all defects and precipiates in the superficial Si layer. In this work we are reporting on the effect of three different post implantation annealing cycles on the structure of oxygen implanted SOI samples which were implanted under the same conditions.


Author(s):  
Z. Liliental-Weber ◽  
C. Nelson ◽  
R. Ludeke ◽  
R. Gronsky ◽  
J. Washburn

The properties of metal/semiconductor interfaces have received considerable attention over the past few years, and the Al/GaAs system is of special interest because of its potential use in high-speed logic integrated optics, and microwave applications. For such materials a detailed knowledge of the geometric and electronic structure of the interface is fundamental to an understanding of the electrical properties of the contact. It is well known that the properties of Schottky contacts are established within a few atomic layers of the deposited metal. Therefore surface contamination can play a significant role. A method for fabricating contamination-free interfaces is absolutely necessary for reproducible properties, and molecularbeam epitaxy (MBE) offers such advantages for in-situ metal deposition under UHV conditions


Author(s):  
Brian Cross

A relatively new entry, in the field of microscopy, is the Scanning X-Ray Fluorescence Microscope (SXRFM). Using this type of instrument (e.g. Kevex Omicron X-ray Microprobe), one can obtain multiple elemental x-ray images, from the analysis of materials which show heterogeneity. The SXRFM obtains images by collimating an x-ray beam (e.g. 100 μm diameter), and then scanning the sample with a high-speed x-y stage. To speed up the image acquisition, data is acquired "on-the-fly" by slew-scanning the stage along the x-axis, like a TV or SEM scan. To reduce the overhead from "fly-back," the images can be acquired by bi-directional scanning of the x-axis. This results in very little overhead with the re-positioning of the sample stage. The image acquisition rate is dominated by the x-ray acquisition rate. Therefore, the total x-ray image acquisition rate, using the SXRFM, is very comparable to an SEM. Although the x-ray spatial resolution of the SXRFM is worse than an SEM (say 100 vs. 2 μm), there are several other advantages.


Author(s):  
J. E. Johnson

In the early years of biological electron microscopy, scientists had their hands full attempting to describe the cellular microcosm that was suddenly before them on the fluorescent screen. Mitochondria, Golgi, endoplasmic reticulum, and other myriad organelles were being examined, micrographed, and documented in the literature. A major problem of that early period was the development of methods to cut sections thin enough to study under the electron beam. A microtome designed in 1943 moved the specimen toward a rotary “Cyclone” knife revolving at 12,500 RPM, or 1000 times as fast as an ordinary microtome. It was claimed that no embedding medium was necessary or that soft embedding media could be used. Collecting the sections thus cut sounded a little precarious: “The 0.1 micron sections cut with the high speed knife fly out at a tangent and are dispersed in the air. They may be collected... on... screens held near the knife“.


Sign in / Sign up

Export Citation Format

Share Document