scholarly journals Longitudinal effect of high frequency training on CPR performance during simulated and actual pediatric cardiac arrest

2021 ◽  
Vol 6 ◽  
pp. 100117
Author(s):  
Aaron Donoghue ◽  
Debra Heard ◽  
Russell Griffin ◽  
Mary Kate Abbadessa ◽  
Shannon Gaines ◽  
...  
Critical Care ◽  
2015 ◽  
Vol 19 (Suppl 1) ◽  
pp. P431 ◽  
Author(s):  
C Endisch ◽  
C Storm ◽  
CJ Ploner ◽  
C Leithner

2019 ◽  
Vol 59 (5) ◽  
pp. 849
Author(s):  
A. B. Sabow ◽  
Y. M. Goh ◽  
I. Zulkifli ◽  
M. Z. Ab Kadir ◽  
U. Kaka ◽  
...  

Electrical stunning is the most widely used stunning method for sheep and goats. Because low frequency head-to-back electrical stunning induces cardiac arrest, it is non-compliant with halal requirements. In addition, conventional head-only electrical stunning method can have adverse effects on carcass and meat quality. To address these issues high-frequency electrical stunning systems were developed. High frequency head-to-back removes the potential for pain and distress compared with non-stunned slaughter and does not induce cardiac arrest like low frequency head-to-back stunning making it appropriate for halal. However, this claim is yet to be proven through a comprehensive neurophysiological study. Thus, the present study examined the effects of different pre-slaughter electrical stunning methods and slaughter without stunning on electroencephalographic and blood biochemistry changes. Thirty-two male Boer crossbred bucks were distributed into four groups of eight animals each and subjected to slaughter without stunning (SWS), low frequency head-only (LFHO) and low frequency head-to-back (LFHB) or high frequency head-to-back electrical stunning (HFHB). Slaughtering of animals with or without stunning was performed under minimal anaesthesia. Based on electroencephalograph results, at slaughter, the SWS animals showed an increase in brain electrical activity, which is consistent with the presence of post slaughter noxious sensory input associated with tissue damage. Meanwhile the electroencephalograph activities decreased immediately after application of electrical stunning in all animals, suggesting that they were insensible to pain during and after the neck cut. Electrical brain activities for goats subjected to HFHB were comparable to those for LFHO and those for LFHB. The percentage of animals that exhibited severe clonic activity was significantly lower after LFHB or HFHB stunning compared with LFHO. The concentrations of catecholamines and hyperglycemia in electrically stunned goats were higher compared with those from SWS. It was observed that LFHB caused cardiac arrest in all goats whereas all HFHB goats had no cardiac arrest. High frequency head-to-back electrical stunning may be an improvement on non-stunned slaughter and has advantages for meat quality. However, stunning effectiveness after head-to-back electrical stunning with high frequencies needs to be evaluated under industrial conditions before any recommendation is given.


Resuscitation ◽  
2020 ◽  
Vol 146 ◽  
pp. 26-31 ◽  
Author(s):  
Ashish R. Panchal ◽  
Gregory Norton ◽  
Emily Gibbons ◽  
Jeri Buehler ◽  
Michael C. Kurz

2018 ◽  
pp. 391-399 ◽  
Author(s):  
R. SKULEC ◽  
D. ASTAPENKO ◽  
R. CERNA PARIZKOVA ◽  
B. FURST ◽  
M. BILSKA ◽  
...  

We conducted an experimental study to evaluate the presence of coordinated left ventricular mechanical myocardial activity (LVMA) in two types of experimentally induced cardiac arrest: ventricular fibrillation (VF) and pulseless electrical activity (PEA). Twenty anesthetized domestic pigs were randomized 1:1 either to induction of VF or PEA. They were left in nonresuscitated cardiac arrest until the cessation of LVMA and microcirculation. Surface ECG, presence of LVMA by transthoracic echocardiography and sublingual microcirculation were recorded. One minute after induction of cardiac arrest, LVMA was identified in all experimental animals. In the PEA group, rate of LVMA was of 106±12/min. In the VF group, we identified two patterns of LVMA. Six animals exhibited contractions of high frequency (VFhigh group), four of low frequency (VFlow group) (334±12 vs. 125±32/min, p<0.001). A time from cardiac arrest induction to asystole (19.2±7.2 vs. 7.3±2.2 vs. 8.3±5.5 min, p=0.003), cessation of LVMA (11.3±5.6 vs. 4.4±0.4 vs. 7.4±2.9 min, p=0.027) and cessation of microcirculation (25.3±12.6 vs. 13.4±2.4 vs. 23.2±8.7 min, p=0.050) was significantly longer in VFlow group than in VFhigh and PEA group, respectively. Thus, LVMA is present in both VF and PEA type of induced cardiac arrest and moreover, VF may exhibit various patterns of LVMA.


Author(s):  
W. E. Lee ◽  
A. H. Heuer

IntroductionTraditional steatite ceramics, made by firing (vitrifying) hydrous magnesium silicate, have long been used as insulators for high frequency applications due to their excellent mechanical and electrical properties. Early x-ray and optical analysis of steatites showed that they were composed largely of protoenstatite (MgSiO3) in a glassy matrix. Recent studies of enstatite-containing glass ceramics have revived interest in the polymorphism of enstatite. Three polymorphs exist, two with orthorhombic and one with monoclinic symmetry (ortho, proto and clino enstatite, respectively). Steatite ceramics are of particular interest a they contain the normally unstable high-temperature polymorph, protoenstatite.Experimental3mm diameter discs cut from steatite rods (∼10” long and 0.5” dia.) were ground, polished, dimpled, and ion-thinned to electron transparency using 6KV Argon ions at a beam current of 1 x 10-3 A and a 12° angle of incidence. The discs were coated with carbon prior to TEM examination to minimize charging effects.


Author(s):  
G. Y. Fan ◽  
J. M. Cowley

It is well known that the structure information on the specimen is not always faithfully transferred through the electron microscope. Firstly, the spatial frequency spectrum is modulated by the transfer function (TF) at the focal plane. Secondly, the spectrum suffers high frequency cut-off by the aperture (or effectively damping terms such as chromatic aberration). While these do not have essential effect on imaging crystal periodicity as long as the low order Bragg spots are inside the aperture, although the contrast may be reversed, they may change the appearance of images of amorphous materials completely. Because the spectrum of amorphous materials is continuous, modulation of it emphasizes some components while weakening others. Especially the cut-off of high frequency components, which contribute to amorphous image just as strongly as low frequency components can have a fundamental effect. This can be illustrated through computer simulation. Imaging of a whitenoise object with an electron microscope without TF limitation gives Fig. 1a, which is obtained by Fourier transformation of a constant amplitude combined with random phases generated by computer.


Author(s):  
M. T. Postek ◽  
A. E. Vladar

Fully automated or semi-automated scanning electron microscopes (SEM) are now commonly used in semiconductor production and other forms of manufacturing. The industry requires that an automated instrument must be routinely capable of 5 nm resolution (or better) at 1.0 kV accelerating voltage for the measurement of nominal 0.25-0.35 micrometer semiconductor critical dimensions. Testing and proving that the instrument is performing at this level on a day-by-day basis is an industry need and concern which has been the object of a study at NIST and the fundamentals and results are discussed in this paper.In scanning electron microscopy, two of the most important instrument parameters are the size and shape of the primary electron beam and any image taken in a scanning electron microscope is the result of the sample and electron probe interaction. The low frequency changes in the video signal, collected from the sample, contains information about the larger features and the high frequency changes carry information of finer details. The sharper the image, the larger the number of high frequency components making up that image. Fast Fourier Transform (FFT) analysis of an SEM image can be employed to provide qualitiative and ultimately quantitative information regarding the SEM image quality.


1992 ◽  
Vol 1 (4) ◽  
pp. 52-55 ◽  
Author(s):  
Gail L. MacLean ◽  
Andrew Stuart ◽  
Robert Stenstrom

Differences in real ear sound pressure levels (SPLs) with three portable stereo system (PSS) earphones (supraaural [Sony Model MDR-44], semiaural [Sony Model MDR-A15L], and insert [Sony Model MDR-E225]) were investigated. Twelve adult men served as subjects. Frequency response, high frequency average (HFA) output, peak output, peak output frequency, and overall RMS output for each PSS earphone were obtained with a probe tube microphone system (Fonix 6500 Hearing Aid Test System). Results indicated a significant difference in mean RMS outputs with nonsignificant differences in mean HFA outputs, peak outputs, and peak output frequencies among PSS earphones. Differences in mean overall RMS outputs were attributed to differences in low-frequency effects that were observed among the frequency responses of the three PSS earphones. It is suggested that one cannot assume equivalent real ear SPLs, with equivalent inputs, among different styles of PSS earphones.


2019 ◽  
Vol 28 (1S) ◽  
pp. 209-224 ◽  
Author(s):  
Julia Campbell ◽  
Alison LaBrec ◽  
Connor Bean ◽  
Mashhood Nielsen ◽  
Won So

Sign in / Sign up

Export Citation Format

Share Document