Single Distraction-Rod Constructs in Severe Early-Onset Scoliosis: Indications and Outcomes

Author(s):  
Scott J. Luhmann ◽  
David L. Skaggs ◽  
Joshua Pahys ◽  
Amer Samdani ◽  
Ron El-Hawary
2021 ◽  
Author(s):  
Mandar Deepak Borde ◽  
Sarang Sapare ◽  
Emile Schutgens ◽  
Chadi Ali ◽  
Hilali Noordeen

Abstract Study design A cross-sectional retrospective Level 3 study. Objective To study the serum levels of Titanium and Aluminium ions in patients operated using the magnetically controlled growing rod (MCGR) system. Summary of background data 14 consecutive patients of early onset scoliosis with varying etiology managed with MCGR system with a minimum follow-up of 24 months were selected for the study. The group consisted of two boys (14.3%) and 12 girls (85.7%). The average age of the patients at the time of surgery was 10.4 years (5–15 years). The average period of follow-up was 43.7 months (28–79 months). After informed consent of the subjects and their caretakers, serum levels of titanium and aluminium were measured. These levels were then assessed with regards to the number of screws used, number of distractions and complications. Methods The concentration of titanium and aluminium ions in the serum was measured using high resolution inductively coupled plasma mass spectrometry. Results For the sake of ease of assessment, patients were divided into three etiology-based groups—idiopathic (n = 6), neuromuscular (n = 2) and syndromic (n = 6). The mean serum titanium level was 15.9 μg/L (5.1–28.2 μg/L) while that of aluminium was 0.1 μmol/L (0.1–0.2 μmol/L). Of the 14 patients, 2 (14.2%) patients had mechanical failure (actuator pin dysfunction), 3 (21.4%) had rod breakage requiring revision surgery and one patient (7.1%) had surgical site infection managed with appropriate antibiotics. Patients undergoing revision for rod breakage did not show any metallosis of the tissues during surgery. Conclusion Analysis of patients with scoliosis operated using the magnetic growing rod system concludes that it is accompanied by presence of titanium in the blood but whether clinically significant or not needs to be ascertained by comparison of preoperative and postoperative blood concentrations of the titanium ions in individual subjects. The aluminium ion concentration remains within normal limits. Though implant malfunction may raise the titanium levels in the blood, its clinical significance needs to be determined. The aluminium levels are not affected irrespective to the presence or absence of complications. The long-term effects of raised titanium levels in the blood also warrant further prospective studies designed for precise and deeper analyses.


2020 ◽  
Vol 8 (2) ◽  
pp. 285-293
Author(s):  
Casper Dragsted ◽  
Søren Ohrt-Nissen ◽  
Dennis Winge Hallager ◽  
Niklas Tøndevold ◽  
Thomas Andersen ◽  
...  

2018 ◽  
Vol 12 (4) ◽  
pp. 406-412 ◽  
Author(s):  
A. Grzywna ◽  
A. McClung ◽  
J. Sanders ◽  
P. Sturm ◽  
L. Karlin ◽  
...  

Purpose To investigate paediatric orthopaedists’ cast practices for early onset scoliosis regarding patient selection, cast application, radiographic evaluation, treatment cessation and adjunctive bracing. Methods A casting survey was distributed to all paediatric orthopaedists in Children’s Spine and Growing Spine Study Groups (n = 92). Questions included physician and patient characteristics, technique, treatment, outcomes, radiographic measurements and comparison to other treatments. A total of 55 orthopaedists (60%) responded, and descriptive statistics were calculated on the subset who cast (n = 45). Results A majority of respondents use cast treatment for idiopathic and syndromic scoliosis patients, but not for neuromuscular or congenital scoliosis patients. Major curve angle ranked most important in orthopaedists’ decision to commence cast treatment, in comparison with rib-vertebra angle difference or clinical observations. The major curve angle threshold to initiate casting was a median of 30° (20° to 70°), and the minimum patient age was median ten months (3 to 24). First in-cast and out-of-cast radiographs are taken standing, supine, awake, under anesthesia and/or in traction. In all, 58% consistently cast over or under the arm, while 44% vary position by patient. Respondents were divided about the use of a brace after cast treatment: 22% do not prescribe a brace, 31% always do and 36% do in some patients. Conclusions Future multicentre research studies must standardize radiographic practices and consider age and major curve angle at cast initiation and termination, scoliosis aetiology, shoulder position and treatment duration. Practices need to be aligned or compared in these areas in order to distinguish what makes for the best cast treatment possible. Level of Evidence V, Expert opinion


2017 ◽  
Vol 17 (10) ◽  
pp. 1506-1518 ◽  
Author(s):  
Genevieve Hill ◽  
Srinidhi Nagaraja ◽  
Behrooz A. Akbarnia ◽  
Jeff Pawelek ◽  
Paul Sponseller ◽  
...  

2021 ◽  
Vol 22 (1) ◽  
Author(s):  
Ziyang Liu ◽  
Tie Liu ◽  
Yong Hai ◽  
Lingyun Wu ◽  
Junrui Jonathan Hai ◽  
...  

Abstract Background Obtaining and maintaining final shoulder balance after the entire treatment course is essential for early-onset scoliosis (EOS) patients. The relatively small number of growing-rod (GR) graduates who complete final fusion has resulted in an overall paucity of research on the GR treatment of EOS and a lack of research on the shoulder balance of EOS patients during GR treatment. Methods Twenty-four consecutive patients who underwent GR treatment until final fusion were included. Radiographic shoulder balance parameters, including the radiographic shoulder height (RSH), clavicle angle (CA), and T1 tilt angle (T1T), before and after each step of the entire treatment were measured. Shoulder balance changes from GR implantation to the last follow-up after final fusion were depicted and analysed. Demographic data, surgical-related factors, and radiographic parameters were analysed to identify risk factors for final shoulder imbalance. The shoulder balance of patients at different time points was further analysed to explore the potential effect of the series of GR treatment steps on shoulder balance. Results The RSH showed substantial improvement after GR implantation (P = 0.036), during the follow-up period after final fusion (P = 0.021) and throughout the entire treatment (P = 0.011). The trend of change in the CA was similar to that of the RSH, and the T1T improved immediately after GR implantation (P = 0.037). Further analysis indicated that patients with shoulder imbalance before final fusion showed significantly improved shoulder balance after fusion (P = 0.045), and their RSH values at early postfusion and the final follow-up did not show statistically significant differences from those in the prefusion shoulder balance group (P > 0.05). Early postfusion shoulder imbalance (odds ratio (OR): 19.500; 95% confidence interval (CI) = 1.777–213.949; P = 0.015) was identified as an independent risk factor for final shoulder imbalance. Conclusions Shoulder balance could be improved by GR implantation but often changes during the multistep lengthening process, and the final result is relatively unpredictable. Final fusion could further adjust the prefusion shoulder imbalance. Focusing on the prefusion shoulder balance of GR graduates and providing patients with early shoulder balance after fusion might be necessary.


2014 ◽  
Vol 2 (6) ◽  
pp. 502-503
Author(s):  
Anny Hsu ◽  
Hiroko Matsumoto ◽  
Mark Sullivan ◽  
Evan Trupia ◽  
Benjamin Roye ◽  
...  

2021 ◽  
Author(s):  
Edward Compton ◽  
Purnendu Gupta ◽  
Jaime A. Gomez ◽  
Kenneth D. Illingworth ◽  
David L. Skaggs ◽  
...  

2021 ◽  
Vol Publish Ahead of Print ◽  
Author(s):  
Brandon A. Ramo ◽  
Anna McClung ◽  
Chan-Hee Jo ◽  
James O. Sanders ◽  
Burt Yaszay ◽  
...  

2021 ◽  
Vol Publish Ahead of Print ◽  
Author(s):  
Lacey Magee ◽  
Joshua T. Bram ◽  
Jason B. Anari ◽  
Brandon Ramo ◽  
Oscar H. Mayer ◽  
...  