scholarly journals Rapid screening for SARS-CoV-2 variants of concern in clinical and environmental samples using nested RT-PCR assays targeting key mutations of the spike protein

2021 ◽  
pp. 117104
Author(s):  
G La Rosa ◽  
P. Mancini ◽  
G. Bonanno Ferraro ◽  
C. Veneri ◽  
M. Iaconelli ◽  
...  
2021 ◽  
Author(s):  
G. La Rosa ◽  
P. Mancini ◽  
G. Bonanno Ferraro ◽  
C. Veneri ◽  
M. Iaconelli ◽  
...  

SUMMARYNew SARS-CoV-2 mutations are constantly emerging, raising concerns of increased transmissibility, virulence or escape from host immune response.We describe a nested RT-PCR assay (∼1500 bps) to detect multiple key spike protein mutations distinctive of the major known circulating SARS-CoV-2 variants, including the three Variants of Concern (VOCs) 20I/501Y.V1 (United Kingdom), 20H/501Y.V2 (South Africa), and 20J/501Y.V3 (Brazil), as well as the 20E.EU1 variant (Spain), the CAL.20C recently identified in California, and the mink-associated variant (GR, lineage B.1.1.298). Prior to application to field samples, the discriminatory potential of this PCR assay was explored using GISAID and Nextclade. To extend variant detection to challenging matrices such as sewage, where the amplification of long fragments is problematic, two short nested RT-PCR assays (∼300 bps) were also designed, targeting portions of the region spanned by the long nested assay.The three newly-designed assays were then tested on field samples, including 7 fully-sequenced viral isolates from swab samples and 34 urban wastewater samples, some of which collected in areas where circulation of VOCs had been reported.The long assay successfully amplified all the previously characterized viral isolates, allowing the correct identification of variants 20I/501Y.V1 and 20E.EU1 present in the panel. The sequences obtained using the short assays were consistent with those obtained with the long assay. Mutations characteristic of VOCs (UK and Brazilian variant) and of other variant (Spanish) were detected in sewage samples. To our knowledge, this is the first evidence of the presence of sequences harboring key mutations of 20I/501Y.V1 and 20J/501Y.V3 in urban wastewaters, highlighting the potential contribution of wastewater surveillance to explore SARS-CoV-2 diversity.The developed nested RT-PCR assays can be used as an initial rapid screening test to select clinical samples containing mutations of interest. This can speed up diagnosis and optimize resources since it allows full genome sequencing to be done only on clinically relevant specimens. The assays can be also employed for a rapid and cost-effective detection of VOCs or other variants in sewage for the purposes of wastewater-based epidemiology. The approach proposed here can be used to better understand SARS-CoV-2 variant diversity, geographic distribution and impact worldwide.


1998 ◽  
Vol 38 (12) ◽  
pp. 91-94 ◽  
Author(s):  
M. D. Sobsey ◽  
D. A. Battigelli ◽  
G.-A. Shin ◽  
S. Newland

Nucleic acid (NA) amplification techniques are useful to detect viruses in water and other environmental samples because they are highly sensitive, specific and can detect fastidious enteric viruses that do not grow well or not at all in cell cultures. However, RT-PCR was found to detect inactivated viruses. In terms of risks to public health this constitutes a false positive result, as inactivated viruses are no longer infectious. When poliovirus type 1 and coliphage MS2 were studied for (a) persistence in water and sewage and (b) inactivation in water by free chlorine, chlorine dioxide and UV radiation, RT-PCR assays underestimated virus inactivation. The use of multiple RT-PCR amplification sites, larger RT-PCR genomic targets and immunocapture RT-PCR sometimes reduced, but did not eliminate, the discrepancy between loss of infectivity and loss of RT-PCR titre. Virus presence based on RT-PCR detection must be interpreted with caution when predicting human health risks.


1995 ◽  
Vol 31 (5-6) ◽  
pp. 371-374 ◽  
Author(s):  
R. Gajardo ◽  
R. M. Pintó ◽  
A. Bosch

A reverse transcription polymerase chain reaction (RT-PCR) assay is described that has been developed for the detection and serotyping of group A rotavirus in stool specimens and concentrated and non-concentrated sewage specimens.


Author(s):  
Ute Eberle ◽  
◽  
Clara Wimmer ◽  
Ingrid Huber ◽  
Antonie Neubauer-Juric ◽  
...  

AbstractTo face the COVID-19 pandemic, the need for fast and reliable diagnostic assays for the detection of SARS-CoV-2 is immense. We describe our laboratory experiences evaluating nine commercially available real-time RT-PCR assays. We found that assays differed considerably in performance and validation before routine use is mandatory.


2021 ◽  
Vol 28 (1) ◽  
pp. 847-852
Author(s):  
Anna Ferrari ◽  
Marco Trevenzoli ◽  
Lolita Sasset ◽  
Elisabetta Di Liso ◽  
Toni Tavian ◽  
...  

The pandemic of SARS-CoV-2 is a serious global challenge affecting millions of people worldwide. Cancer patients are at risk for infection exposure and serious complications. A prompt diagnosis of SARS-CoV-2 infection is crucial for the timely adoption of isolation measures and the appropriate management of cancer treatments. In lung cancer patients the symptoms of infection 19 may resemble those exhibited by the underlying oncologic condition, possibly leading to diagnostic overlap and delays. Moreover, cancer patients might display a prolonged positivity of nasopharyngeal RT-PCR assays for SARS-CoV-2, causing long interruptions or delay of cancer treatments. However, the association between the positivity of RT-PCR assays and the patient’s infectivity remains uncertain. We describe the case of a patient with non-small cell lung cancer, and a severe ab extrinseco compression of the trachea, whose palliative radiotherapy was delayed because of the prolonged positivity of nasopharyngeal swabs for SARS-CoV-2. The patient did not show clinical symptoms suggestive of active infection, but the persistent positivity of RT-PCR assays imposed the continuation of isolation measures and the delay of radiotherapy for over two months. Finally, the negative result of SARS-CoV-2 viral culture allowed us to verify the absence of viral activity and to rule out the infectivity of the patient, who could finally continue her cancer treatment.


Author(s):  
Sophie Edouard ◽  
Rita Jaafar ◽  
Nicolas Orain ◽  
Philippe Parola ◽  
Philippe Colson ◽  
...  

AbstractELISA and chemiluminescence serological assays for COVID-19 are currently incorporating only one or two SARS-CoV-2 antigens. We developed an automated Western immunoblotting as a complementary serologic assay for COVID-19. The JessTM Simple Western system, an automated capillary-based assay, was used, incorporating an inactivated SARS-CoV-2 lineage 20a strain as the source of antigen, and total immunoglobulins (IgG, IgM, IgA) detection. In total, 602 sera were tested including 223 from RT-PCR-confirmed COVID-19 patients, 76 from patients diagnosed with seasonal HCoVs and 303 from coronavirus-negative control sera. We also compared this assay with the EUROIMMUN® SARS-CoV-2 IgG ELISA kit. Among 223 sera obtained from RT-PCR-confirmed COVID-19 patients, 180/223 (81%) exhibited reactivity against the nucleocapsid and 70/223 (31%) against the spike protein. Nucleocapsid reactivity was further detected in 9/76 (14%) samples collected from patients diagnosed with seasonal HCoVs and in 15/303 (5%) coronavirus-negative control samples. In the subset of sera collected more than 2 weeks after the onset of symptoms, the sensitivity was 94% and the specificity 93%, the latter value probably reflecting cross-reactivity of SARS-CoV-2 with other coronaviruses. The automated Western immunoblotting presented a substantial agreement (90%) with the compared ELISA (Cohen’s Kappa=0.64). Automated Western immunoblotting may be used as a second line test to monitor exposure of people to HCoVs including SARS-CoV-2.


Intervirology ◽  
2021 ◽  
pp. 1-6
Author(s):  
Salman Khan ◽  
Syed Asad Ali Shah ◽  
Syed Muhammad Jamal

<b><i>Background:</i></b> Foot-and-mouth disease (FMD) is an infectious and highly contagious disease of cloven-hoofed domestic and wild animals, causing heavy economic losses to the livestock industry. Rapid and reliable diagnosis of the disease is essential for the implementation of effective control measures. This study compared sandwich enzyme-linked immunosorbent assay (S-ELISA) and conventional reverse transcription polymerase chain reaction (RT-PCR) for the diagnosis of FMD. <b><i>Methods:</i></b> A total of 60 epithelial samples from suspected cases of FMD were tested using both S-ELISA and RT-PCR assays. The level of agreement between the assays was assessed by calculating the Kappa value. <b><i>Results:</i></b> S-ELISA detected 38 (63%) samples positive for FMD virus (FMDV). Being predominant, serotype O was detected in 22 (57.9%) of the total samples tested positive, whereas 9 (23.7%) and 7 (18.4%) samples were found positive for serotypes A and Asia-1, respectively. RT-PCR detected viral genome in 51 (85%) of the samples using pan-FMDV primers set, 1F/1R. Thirty-six samples were found positive and 7 negative by both the tests. The level of agreement between the tests was assessed by calculating the Kappa value, which was found to be fair (Kappa value = 0.303 and 95% CI = 0.089; 0.517) and significant (<i>p</i> = 0.009). However, 2 samples, which were found positive on S-ELISA tested negative on RT-PCR. This may be attributed to the presence of nucleotide mismatch(es) in the primer-binding sites that may have resulted in failure of amplification of the viral genome. The serotype-specific RT-PCR assays not only confirmed serotyping results of S-ELISA but were also able to establish serotype in 9 S-ELISA-negative but pan-FMDV RT-PCR-positive samples. <b><i>Conclusions:</i></b> The RT-PCR assay contributes significantly to establishing a quick, sensitive, and definitive diagnosis of FMD in resource-constrained countries. Samples giving negative results in S-ELISA should be tested in RT-PCR for the disease detection and virus typing.


2009 ◽  
Vol 81 (9) ◽  
pp. 1569-1575 ◽  
Author(s):  
Lan Lin ◽  
Louis Libbrecht ◽  
Jannick Verbeeck ◽  
Chris Verslype ◽  
Tania Roskams ◽  
...  

2014 ◽  
Vol 201 ◽  
pp. 79-85 ◽  
Author(s):  
Michele Drigo ◽  
Giovanni Franzo ◽  
Ilaria Belfanti ◽  
Marco Martini ◽  
Alessandra Mondin ◽  
...  

2009 ◽  
Vol 36 (2) ◽  
pp. 133-137 ◽  
Author(s):  
P. M. Dang ◽  
D. L. Rowland ◽  
W. H. Faircloth

Abstract Diagnosis of Tomato spotted wilt virus (TSWV) in peanut can be accomplished by enzyme-linked immunosorbent assay (ELISA) or reverse transcription polymerase chain reaction (RT-PCR) but there has been no report of a direct comparison of the success of the two assays in evaluating infection rates of field-grown peanut. We collected peanut root samples from field-grown plants, 76 in 2006 and 48 in 2007, and tested these samples by both ELISA and RT-PCR assays for the presence of TSWV. Out of 124 samples, 50 (40.3%) and 57 (46.0%) were positive for TSWV by ELISA and RT-PCR respectively. In 13.7% of these samples, ELISA and RT-PCR differed in their results. However, Chi square analysis showed no significant difference between the results for these two assays. This result supports the conclusion that ELISA and RT-PCR are comparable for detecting TSWV infection rates in field-grown peanuts.


Sign in / Sign up

Export Citation Format

Share Document