scholarly journals Feasibility and clinical utility of handheld fundus cameras for retinal imaging

Eye ◽  
2022 ◽  
Author(s):  
Susmit Das ◽  
Helen J. Kuht ◽  
Ian De Silva ◽  
Sundeep S. Deol ◽  
Lina Osman ◽  
...  

Abstract Background/objectives Handheld fundus cameras are portable and cheaper alternatives to table-top counterparts. To date there have been no studies comparing feasibility and clinical utility of handheld fundus cameras to table-top devices. We compare the feasibility and clinical utility of four handheld fundus cameras (Remidio NMFOP, Volk Pictor Plus, Volk iNview, oDocs visoScope) to a table-top camera (Zeiss VisucamNM/FA). Subjects/methods Healthy participants (n = 10, mean age ± SD = 21.0 ± 0.9 years) underwent fundus photography with five fundus cameras to assess success/failure rates of image acquisition. Participants with optic disc abnormalities (n = 8, mean age ± SD = 26.8 ± 15.9) and macular abnormalities (n = 10, mean age ± SD = 71.6 ± 15.4) underwent imaging with the top three scoring fundus cameras. Images were randomised and subsequently validated by ophthalmologists masked to the diagnoses and devices used. Results Image acquisition success rates (100%) were achieved in non-mydriatic and mydriatic settings for Zeiss, Remidio and Pictor, compared with lower success rates for iNview and oDocs. Image quality and gradeability were significantly higher for Zeiss, Remidio and Pictor (p < 0.0001) compared to iNview and oDocs. For cup:disc ratio estimates, similar levels of bias were seen for Zeiss (−0.09 ± SD:0.15), Remidio (−0.07 ± SD:0.14) and Pictor (−0.05 ± SD:0.16). Diagnostic sensitivities were highest for Zeiss (84.9%; 95% CI, 78.2–91.5%) followed by Pictor (78.1%; 95% CI, 66.6–89.5%) and Remidio (77.5%; 95% CI, 65.9–89.0%). Conclusions Remidio and Pictor achieve comparable results to the Zeiss table-top camera. Both devices achieved similar scores in feasibility, image quality, image gradeability and diagnostic sensitivity. This suggests that these devices potentially offer a more cost-effective alternative in certain clinical scenarios.

2007 ◽  
Vol 4 (6) ◽  
pp. 371-388 ◽  
Author(s):  
Mark B. Williams ◽  
Elizabeth A. Krupinski ◽  
Keith J. Strauss ◽  
William K. Breeden ◽  
Mark S. Rzeszotarski ◽  
...  

1993 ◽  
Vol 72 (1) ◽  
pp. 347-350
Author(s):  
James W. Siddall ◽  
Nancy J. Keogh

The accuracy and clinical utility of computerized interpretive reports for the Diagnostic Inventory of Personality and Symptoms were explored for 540 clients of a drug treatment center. The modal profile for substance abusers was identified and the accuracy of the substance abuse scales was assessed. 9 chemical dependency counselors rated the computer reports for usefulness and compared these retrospectively with similar reports based on the MMPI and Millon's MCMI. The results suggested the Diagnostic Inventory of Personality and Symptoms accurately identifies substance abusers, provides useful information for treatment, and offers a cost-effective alternative to the MMPI and MCMI.


Author(s):  
James F. Mancuso

IBM PC compatible computers are widely used in microscopy for applications ranging from control to image acquisition and analysis. The choice of IBM-PC based systems over competing computer platforms can be based on technical merit alone or on a number of factors relating to economics, availability of peripherals, management dictum, or simple personal preference.IBM-PC got a strong “head start” by first dominating clerical, document processing and financial applications. The use of these computers spilled into the laboratory where the DOS based IBM-PC replaced mini-computers. Compared to minicomputer, the PC provided a more for cost-effective platform for applications in numerical analysis, engineering and design, instrument control, image acquisition and image processing. In addition, the sitewide use of a common PC platform could reduce the cost of training and support services relative to cases where many different computer platforms were used. This could be especially true for the microscopists who must use computers in both the laboratory and the office.


2020 ◽  
pp. 1192-1198
Author(s):  
M.S. Mohammad ◽  
Tibebe Tesfaye ◽  
Kim Ki-Seong

Ultrasonic thickness gauges are easy to operate and reliable, and can be used to measure a wide range of thicknesses and inspect all engineering materials. Supplementing the simple ultrasonic thickness gauges that present results in either a digital readout or as an A-scan with systems that enable correlating the measured values to their positions on the inspected surface to produce a two-dimensional (2D) thickness representation can extend their benefits and provide a cost-effective alternative to expensive advanced C-scan machines. In previous work, the authors introduced a system for the positioning and mapping of the values measured by the ultrasonic thickness gauges and flaw detectors (Tesfaye et al. 2019). The system is an alternative to the systems that use mechanical scanners, encoders, and sophisticated UT machines. It used a camera to record the probe’s movement and a projected laser grid obtained by a laser pattern generator to locate the probe on the inspected surface. In this paper, a novel system is proposed to be applied to flat surfaces, in addition to overcoming the other limitations posed due to the use of the laser projection. The proposed system uses two video cameras, one to monitor the probe’s movement on the inspected surface and the other to capture the corresponding digital readout of the thickness gauge. The acquired images of the probe’s position and thickness gauge readout are processed to plot the measured data in a 2D color-coded map. The system is meant to be simpler and more effective than the previous development.


Alloy Digest ◽  
1980 ◽  
Vol 29 (11) ◽  

Abstract JS777 is a high-alloy, fully austenitic stainless steel developed for applications where corrosive conditions are too severe for the standard grades of stainless steel. It also provides a cost-effective alternative to more expensive nickel-base and titanium-base alloys. It has relatively high resistance to stress-corrosion cracking and to intergranular corrosion. This datasheet provides information on composition, physical properties, hardness, elasticity, and tensile properties. It also includes information on corrosion resistance as well as forming, heat treating, machining, joining, and surface treatment. Filing Code: SS-377. Producer or source: Jessop Steel Company.


Alloy Digest ◽  
2009 ◽  
Vol 58 (11) ◽  

Abstract Ancorsteel 4300 alloy ferrous powder simulates wrought steel compositions and is a cost-effective alternative to alloys requiring secondary processing. This datasheet provides information on composition, physical properties, hardness, and tensile properties as well as fracture toughness. It also includes information on heat treating and powder metal forms. Filing Code: SA-611. Producer or source: Hoeganaes Corporation.


Author(s):  
Priyanka T K ◽  
V.N. K. Usha ◽  
Sucheta Kumari M

Garbha is a conglomeration of biological mass with different strata including consciousness, needs an innovative clinical tool to evaluate its well being, which proves safe, potent, cost-effective and noninvasive. The idea of taking up this study was to sensitively predict the Prakrutavastha or well being w.r.t Garbha-pushti and ongoing Fetal Pathology, Vaikrutavastha w.s.r Garbhavyapads for a sharp interference to get a possible best neonatal outcome. The objective of this study was to calculate the predictive accuracy of evaluation of Garbhaspandanam on external Shabda and Sparsha Pareeksha. A Prospective Clinical study of Garbhaspandanam (FHS and FM) with external Shabda and Sparsha stimulation on maternal abdomen, from 24th week onwards was conducted in a cohort of 30 Singleton Pregnant women at Dept. of Prasuti Tantra and Stri Roga, S.D.M.C.A. Hospital, Udupi. Among the 9 cases in abnormal category, 2 cases had gone for IUD and one case though placed in abnormal category had responded relatively well to Shabda and Sparsha Pareeksha which may be due to the proper antenatal care and intervention given along with the patient’s Vatakara Nidana Parivarjana. Predictive Accuracy Rate on Shabda and Sparsha Pareeksha showed, FHS 70%, FM 76.7%; FHS 73.3%, FM 66.7% respectively. Shabda and Sparshapareeksha can be utilized as the Garbha - chetana - dyodakalakshana and can be performed as a routine antenatal bedside procedure, which can fairly detect the Prakruta and Vaikrutavastha of Garbha w.r.t Pushti. However larger prospective studies are required.


2021 ◽  
Vol 80 (Suppl 1) ◽  
pp. 119-120
Author(s):  
N. Østerås ◽  
E. Aas ◽  
T. Moseng ◽  
L. Van Bodegom-Vos ◽  
K. Dziedzic ◽  
...  

Background:To improve quality of care for patients with hip and knee osteoarthritis (OA), a structured model for integrated OA care was developed based on international treatment recommendations. A previous analysis of a cluster RCT (cRCT) showed that compared to usual care, the intervention group reported higher quality of care and greater satisfaction with care. Also, more patients were treated according to international guidelines and fulfilled recommendations for physical activity at the 6-month follow-up.Objectives:To assess the cost-utility of a structured model for hip or knee OA care.Methods:A cRCT with stepped-wedge cohort design was conducted in 6 Norwegian municipalities (clusters) in 2015-17. The OA care model was implemented in one cluster at the time by switching from “usual care” to the structured model. The implementation of the model was facilitated by interactive workshops for general practitioners (GPs) and physiotherapists (PTs) with an update on OA treatment recommendations. The GPs explained the OA diagnosis and treatment alternatives, provided pharmacological treatment when appropriate, and suggested referral to physiotherapy. The PT-led patient OA education programme was group-based and lasted 3 hours followed by an 8–12-week individually tailored resistance exercise programme with twice weekly 1-hour supervised group sessions (5–10 patients per PT). An optional 10-hours Healthy Eating Program was available. Participants were ≥45 years with symptomatic hip or knee OA.Costs were measured from the healthcare perspective and collected from several sources. Patients self-reported visits in primary healthcare at 3, 6, 9 and 12 months. Secondary healthcare visits and joint surgery data were extracted from the Norwegian Patient Register. The health outcome, quality-adjusted life-year (QALY), was estimated based on the EQ-5D-5L scores at baseline, 3, 6, 9 and 12 months. The result of the cost-utility analysis was reported using the incremental cost-effectiveness ratio (ICER), defined as the incremental costs relative to incremental QALYs (QALYs gained). Based on Norwegian guidelines, the threshold is €27500. Sensitivity analyses were performed using bootstrapping to assess the robustness of reported results and presented in a cost-effectiveness plane (Figure 1).Results:The 393 patients’ mean age was 63 years (SD 9.6) and 74% were women. 109 patients were recruited during control periods (control group), and 284 patients were recruited during interventions periods (intervention group). Only the intervention group had a significant increase in EQ-5D-5L utility scores from baseline to 12 months follow-up (mean change 0.03; 95% CI 0.01, 0.05) with QALYs gained: 0.02 (95% CI -0.08, 0.12). The structured OA model cost approx. €301 p.p. with an additional €50 for the Healthy Eating Program. Total 12 months healthcare cost p.p. was €1281 in the intervention and €3147 in the control group, resulting in an incremental cost of -€1866 (95% CI -3147, -584) p.p. Costs related to surgical procedures had the largest impact on total healthcare costs in both groups. During the 12-months follow-up period, 5% (n=14) in the intervention compared to 12% (n=13) in the control group underwent joint surgery; resulting in a mean surgical procedure cost of €553 p.p. in the intervention as compared to €1624 p.p. in the control group. The ICER was -€93300, indicating that the OA care model resulted in QALYs gained and cost-savings. At a threshold of €27500, it is 99% likely that the OA care model is a cost-effective alternative.Conclusion:The results of the cost-utility analysis show that implementing a structured model for OA care in primary healthcare based on international guidelines is highly likely a cost-effective alternative compared to usual care for people with hip and knee OA. More studies are needed to confirm this finding, but this study results indicate that implementing structured OA care models in primary healthcare may be beneficial for the individual as well as for the society.Disclosure of Interests:None declared


2021 ◽  
Vol 7 (1) ◽  
Author(s):  
Muhammad Ashar Naveed ◽  
Muhammad Afnan Ansari ◽  
Inki Kim ◽  
Trevon Badloe ◽  
Joohoon Kim ◽  
...  

AbstractHelicity-multiplexed metasurfaces based on symmetric spin–orbit interactions (SOIs) have practical limits because they cannot provide central-symmetric holographic imaging. Asymmetric SOIs can effectively address such limitations, with several exciting applications in various fields ranging from asymmetric data inscription in communications to dual side displays in smart mobile devices. Low-loss dielectric materials provide an excellent platform for realizing such exotic phenomena efficiently. In this paper, we demonstrate an asymmetric SOI-dependent transmission-type metasurface in the visible domain using hydrogenated amorphous silicon (a-Si:H) nanoresonators. The proposed design approach is equipped with an additional degree of freedom in designing bi-directional helicity-multiplexed metasurfaces by breaking the conventional limit imposed by the symmetric SOI in half employment of metasurfaces for one circular handedness. Two on-axis, distinct wavefronts are produced with high transmission efficiencies, demonstrating the concept of asymmetric wavefront generation in two antiparallel directions. Additionally, the CMOS compatibility of a-Si:H makes it a cost-effective alternative to gallium nitride (GaN) and titanium dioxide (TiO2) for visible light. The cost-effective fabrication and simplicity of the proposed design technique provide an excellent candidate for high-efficiency, multifunctional, and chip-integrated demonstration of various phenomena.


Sign in / Sign up

Export Citation Format

Share Document