Estimating Venusian thermal conditions using multiring basin morphology

2021 ◽  
Author(s):  
E. Bjonnes ◽  
B. C. Johnson ◽  
A. J. Evans
2018 ◽  
pp. 155-162 ◽  
Author(s):  
Sergei S. Kapitonov ◽  
Anastasia V. Kapitonova ◽  
Sergei Yu. Grigorovich ◽  
Sergei A. Medvedev ◽  
Taher Sobhy

In the article, the electrical and thermal processes in the LED lamp with varied parameters are investigated. Voltage and current measurements on all LEDs of the luminaire are carried out in the nominal operating mode. The power allocated to each LED is determined. The calculation of the LED crystal temperature was carried out using the developed thermal LED model based on the results of the measurements and by using “Multisim” program. It has been established that the temperature of the crystals of individual LEDs in the luminaire differ significantly, which leads to unfavourable thermal conditions for them and an increased likelihood of premature failure.


2017 ◽  
Vol 191 ◽  
pp. 176-195 ◽  
Author(s):  
Igor D. Rostov ◽  
Elena V. Dmitrieva ◽  
Alexander A. Vorontsov

2020 ◽  
Vol 38 (9A) ◽  
pp. 1257-1275
Author(s):  
Wisam M. Mareed ◽  
Hasanen M. Hussen

 Elevated CO2 rates in a building affect the health of the occupant. This paper deals with an experimental and numerical analysis conducted in a full-scale test room located in the Department of Mechanical Engineering at the University of Technology. The experiments and CFD were conducted for analyzing ventilation performance. It is a study on the effect of the discharge airflow rate of the ceiling type air-conditioner on ventilation performance in the lecture room with the mixing ventilation. Most obtained findings show that database and questionnaires analyzed prefer heights between 0.2 m to 1.2 m in the middle of an occupied zone and breathing zone height of between 0.75 m to 1.8 given in the literature surveyed. It is noticed the mismatch of internal conditions with thermal comfort, and indoor air quality recommended by [ASHRAE Standard 62, ANSI / ASHRAE Standard 55-2010]. CFD simulations have been carried to provide insights on the indoor air quality and comfort conditions throughout the classroom. Particle concentrations, thermal conditions, and modified ventilation system solutions are reported.


2020 ◽  
pp. 75-86
Author(s):  
Sergio Antonio Camargo ◽  
Lauro Correa Romeiro ◽  
Carlos Alberto Mendes Moraes

The present article aimed to test changes in cooling water temperatures of males, present in aluminum injection molds, to reduce failures due to thermal fatigue. In order to carry out this work, cooling systems were studied, including their geometries, thermal gradients and the expected theoretical durability in relation to fatigue failure. The cooling system tests were developed with the aid of simulations in the ANSYS software and with fatigue calculations, using the method of Goodman. The study of the cooling system included its geometries, flow and temperature of this fluid. The results pointed to a significant increase in fatigue life of the mold component for the thermal conditions that were proposed, with a significant increase in the number of cycles, to happen failures due to thermal fatigue.


Author(s):  
Boris A. Sokolov ◽  
Pavel A. Shcherbina ◽  
Ivan B. Sishko ◽  
Aleksandr V. Shipovskiy Aleksandr ◽  
Aleksandr A. Lyapin ◽  
...  

The paper demonstrates the feasibility of using iodine as propellant for thrusters with closed electron drift and its economic viability. It describes a test setup for running experiments. It provides the results of experimental studies of the stationary plasma thruster using iodine as its propellant with xenon gas-passage hollow cathode, as well as of the operational mode of the thruster where a mixture of xenon and iodine is used. During tests gas dynamic and electrical properties of the thruster were analyzed. Thermal conditions in the iodine storage and supply system were studied. Conclusions were drawn on how the test object could be improved and upgraded. The paper describes the option to use a thermionic non-flow cathode as the compensator cathode for the operation of the iodine thruster. The paper provides the results of an experimental study of the prototype non-flow compensator cathode in diode mode. Based on the results of the studies an experimental facility was built for testing a thruster with non-flow compensator cathode. Key words: cathode, compensator cathode, thruster with closed electron drift, stationary plasma thruster, iodine.


2004 ◽  
Vol 39 (3) ◽  
pp. 175-182 ◽  
Author(s):  
Keith B. Tierney ◽  
Eric Stockner ◽  
Christopher J. Kennedy

Abstract This study explored the effects of a sublethal 96-h dehydroabietic acid (DHAA) exposure on aspects of the immune system of juvenile coho salmon under varying temperature conditions. Coho were exposed to DHAA concentrations below the determined LC50 value of 0.94 mg/L (95% confidence limits of 0.81 to 1.24 mg/L) for 96 h at either their acclimation temperature (8 or 18°C), or during an acute warm-shock (8 to 18°C) or cold-shock (18 to 8°C). Acclimation temperature alone significantly affected hematocrit (Hct), neutrophil respiratory burst activity (RBA) and leucocyte proportions. With temperature-shock, leucocrit (Lct), RBA and leucocyte proportions were altered. All parameters were affected by DHAA exposure, but not always in a dose-dependent manner. Across groups, DHAA caused Hct, lysozyme, thrombocyte, neutrophil and monocyte proportions to increase, and Lct, RBA and lymphocyte proportions to decrease. DHAA-temperature interactions resulted in the exacerbation of DHAA-induced effects. Exposure temperature had the most significant effect on the susceptibility of coho to Aeromonas salmonicida; fish were more susceptible at cold temperatures and when subjected to a temperature-shock compared to their respective controls. DHAA exposure modulated the response of temperature-shocked fish to this pathogen.


Sign in / Sign up

Export Citation Format

Share Document