scholarly journals Validation of a combined ultrasound and bioluminescence imaging system with magnetic resonance imaging in orthotopic pancreatic murine tumors

2022 ◽  
Vol 12 (1) ◽  
Author(s):  
Juan D. Rojas ◽  
Jordan B. Joiner ◽  
Brian Velasco ◽  
Kathlyne Jayne B. Bautista ◽  
Adam M. Aji ◽  
...  

AbstractPreclinical mouse solid tumor models are widely used to evaluate efficacy of novel cancer therapeutics. Recent reports have highlighted the need for utilizing orthotopic implantation to represent clinical disease more accurately, however the deep tissue location of these tumors makes longitudinal assessment challenging without the use of imaging techniques. The purpose of this study was to evaluate the performance of a new multi-modality high-throughput in vivo imaging system that combines bioluminescence imaging (BLI) with robotic, hands-free ultrasound (US) for evaluating orthotopic mouse models. Long utilized in cancer research as independent modalities, we hypothesized that the combination of BLI and US would offer complementary advantages of detection sensitivity and quantification accuracy, while mitigating individual technological weaknesses. Bioluminescent pancreatic tumor cells were injected into the pancreas tail of C57BL/6 mice and imaged weekly with the combination system and magnetic resonance imaging (MRI) to serve as a gold standard. BLI photon flux was quantified to assess tumor activity and distribution, and US and MRI datasets were manually segmented for gross tumor volume. Robotic US and MRI demonstrated a strong agreement (R2 = 0.94) for tumor volume measurement. BLI showed a weak overall agreement with MRI (R2 = 0.21), however, it offered the greatest sensitivity to detecting the presence of tumors. We conclude that combining BLI with robotic US offers an efficient screening tool for orthotopic tumor models.

1995 ◽  
Vol 13 (6) ◽  
pp. VI-VII
Author(s):  
Machida Yoshio ◽  
Hatanaka Masahiko ◽  
Kitane Shinichi

1987 ◽  
Vol 21 (2) ◽  
pp. 204-207 ◽  
Author(s):  
Hidehiko Nabatame ◽  
Hidenao Fukuyama ◽  
Ichiro Akiguchi ◽  
Masakuni Kameyama ◽  
Kazumasa Nishimura ◽  
...  

2016 ◽  
Vol 16 (6) ◽  
pp. 294-299 ◽  
Author(s):  
S. Solis-Najera ◽  
F. Vazquez ◽  
R. Hernandez ◽  
O. Marrufo ◽  
A.O. Rodriguez

Abstract A surface radio frequency coil was developed for small animal image acquisition in a pre-clinical magnetic resonance imaging system at 7 T. A flexible coil composed of two circular loops was developed to closely cover the object to be imaged. Electromagnetic numerical simulations were performed to evaluate its performance before the coil construction. An analytical expression of the mutual inductance for the two circular loops as a function of the separation between them was derived and used to validate the simulations. The RF coil is composed of two circular loops with a 5 cm external diameter and was tuned to 300 MHz and 50 Ohms matched. The angle between the loops was varied and the Q factor was obtained from the S11 simulations for each angle. B1 homogeneity was also evaluated using the electromagnetic simulations. The coil prototype was designed and built considering the numerical simulation results. To show the feasibility of the coil and its performance, saline-solution phantom images were acquired. A correlation of the simulations and imaging experimental results was conducted showing a concordance of 0.88 for the B1 field. The best coil performance was obtained at the 90° aperture angle. A more realistic phantom was also built using a formaldehyde-fixed rat phantom for ex vivo imaging experiments. All images showed a good image quality revealing clearly defined anatomical details of an ex vivo rat.


Neurosurgery ◽  
2011 ◽  
Vol 69 (4) ◽  
pp. 852-863 ◽  
Author(s):  
Daniela Kuhnt ◽  
Oliver Ganslandt ◽  
Sven-Martin Schlaffer ◽  
Michael Buchfelder ◽  
Christopher Nimsky

Abstract BACKGROUND: The beneficial role of the extent of resection (EOR) in glioma surgery in correlation to increased survival remains controversial. However, common literature favors maximum EOR with preservation of neurological function, which is shown to be associated with a significantly improved outcome. OBJECTIVE: In order to obtain a maximum EOR, it was examined whether high-field intraoperative magnetic resonance imaging (iMRI) combined with multimodal navigation contributes to a significantly improved EOR in glioma surgery. METHODS: Two hundred ninety-three glioma patients underwent craniotomy and tumor resection with the aid of intraoperative 1.5 T MRI and integrated multimodal navigation. In cases of remnant tumor, an update of navigation was performed with intraoperative images. Tumor volume was quantified pre- and intraoperatively by segmentation of T2 abnormality in low-grade and contrast enhancement in high-grade gliomas. RESULTS: In 25.9% of all cases examined, additional tumor mass was removed as a result of iMRI. This led to complete tumor resection in 20 cases, increasing the rate of gross-total removal from 31.7% to 38.6%. In 56 patients, additional but incomplete resection was performed because of the close location to eloquent brain areas. Volumetric analysis showed a significantly (P < .01) reduced mean percentage of tumor volume following additional further resection after iMRI from 33.5% ± 25.1% to 14.7% ± 23.3% (World Health Organization [WHO] grade I, 32.8% ± 21.9% to 6.1% ± 18.8%; WHO grade II, 24.4% ± 25.1% to 10.8% ± 11.0%; WHO grade III, 35.1% ± 27.3% to 24.8% ± 26.3%; WHO grade IV, 34.2% ± 23.7% to 1.2% ± 16.2%). CONCLUSION: MRI in conjunction with multimodal navigation and an intraoperative updating procedure enlarges tumor-volume reduction in glioma surgery significantly without higher postoperative morbidity.


Sign in / Sign up

Export Citation Format

Share Document