scholarly journals Effects of practitioner’s experience on the clinical performance of ultrasound-guided central venous catheterization: a randomized trial

2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Hyun-Kyu Yoon ◽  
Min Hur ◽  
Hyeyeon Cho ◽  
Young Hyun Jeong ◽  
Ho-Jin Lee ◽  
...  

AbstractWe investigated whether two needle insertion techniques for ultrasound-guided internal jugular vein (IJV) catheterization differ in the number of needling attempts and complication rate between inexperienced and experienced practitioners. A total of 308 patients requiring IJV catheterization were randomly assigned into one of four groups: IJV catheterization performed by inexperienced practitioners using either Seldinger (IE-S; n = 78) or modified Seldinger technique (IE-MS; n = 76) or IJV catheterization performed by experienced practitioners using either Seldinger (E-S; n = 78) or modified Seldinger technique (E-MS; n = 76). All catheterizations were performed under the real-time ultrasound guidance. The number of needling attempts was not significantly different between the two techniques within each experience group (between IE-S vs. IE-MS P = 0.550, between E-S and E-MS P = 0.834). Time to successful catheterization was significantly shorter in the E-S group compared to E-MS group (P < 0.001) while no significant difference between IE-S and IE-MS groups (P = 0.226). Complication rate was not significantly different between the two techniques within each experience group. Practitioner’s experience did not significantly affect the clinical performance of needle insertion techniques during ultrasound-guided IJV catheterization except the time to successful catheterization. Regarding the number of needling attempts and complication rate, both techniques could be equally recommended regardless of practitioner’s experience.Trial registration: clinicaltrials.gov (https://clinicaltrials.gov/ct2/show/NCT03077802).

2017 ◽  
Vol 71 (1) ◽  
pp. 44-49
Author(s):  
Darko Sazdov ◽  
Marija Jovanovski Srceva ◽  
Zorka Nikolova Todorova

Abstract Introduction. Central venous catheterization of the subclavian vein can be achieved with a landmark and an ultrasound-guided method. Using ultrasound the vein can be catheterized with a long axis in plane or a short axis out of plane approach and a combined approach. The aim of the study was to compare the success, average number of attempts and mechanical complication rate between the landmark and the combined ultrasound-guided method. Methods. A total of 162 adult patients from the Intensive Care Unit at Clinical Hospital Acibadem-Sistina, Skopje were included in this prospective study. Patients randomized in the examined group (n=71) were catheterized with real-time ultrasound guidance with a combined short axis out of plane and long axis in plane method. Patients randomized in the control group (n=91) were catheterized with the landmark method. Subclavian vein was catheterized in both groups. Overall success, success on first attempt, number of attempts and complications at the moment of catheterization were the main outcome measures. Results. Catheterization using the landmark method was successful in 94.5% of patients, 65.9% of which during the first attempt. Cannulation using real-time ultrasound guidance was successful in all patients with a first pas success of 83.1%. The complication rate in the ultrasound group was 2.82% and 16.5% in the landmark group (p=0.004404). Conclusion. Real-time ultrasound guidance with a combined short axis out of plane and long axis in plane approach improves success, decreases number of attempts, and reduces mechanical complications rate.


PRILOZI ◽  
2017 ◽  
Vol 38 (2) ◽  
pp. 107-114 ◽  
Author(s):  
Darko Sazdov ◽  
Marija Jovanovski Srceva ◽  
Zorka Nikolova Todorova

Abstract Introduction: Central venous catheterization is performed by the landmark method and ultrasound guided method. The purpose of the study was to compare the success, average number of attempts, average time to return of blood, and complication rate between the two methods. Material and Methods: This was a prospective study done in the Intensive Care Unit of the Acibadem Sistina Clinical Hospital, in Skopje. There were 400 patients in need of central venous catheter and they were prospectively randomized in two groups. The patients randomized in the examined-ultrasound group underwent real-time ultrasound-guided catheterization and the patients randomized in the control-landmark group were catheterized using the landmark method. Internal Jugular, Subclavian and Femoral vein were catheterized in both groups. The Overall success, success on the first attempt, time to the return of blood, number of attempts and complications at the moment of catheterization such as arterial puncture, pneumothorax and hematoma formation were the main outcome measures. Results: The catheterization using the landmark method was successful in 90.5% of patients, 60.5% of which during the first attempt. The cannulation using real-time ultrasound guidance was successful in 98% of patients with a first pass success of 77%. The complication rate with the landmark method was 14.5% versus 4% with real-time ultrasound guidance p<0.05(p=0.0008). Conclusion: Real-time ultrasound guidance improves success, decreases number of attempts, decreases average time to the return of blood and reduces mechanical complications rate.


2016 ◽  
Vol 3 (1) ◽  
pp. 18-21 ◽  
Author(s):  
Santosh Sharma Parajuli ◽  
Jeju Nath Pokharel

Background: Catheterization of internal jugular vein can be achieved by either anatomical landmark technique or the ultrasound guided technique. The objective of our study is to find out if ultrasound guided technique could be beneficial in placing central venous catheters by improving the success rate by reducing the number of attempts, decreasing the access time and decreasing the complications rate in comparison to the landmark technique.Methods: Fifty patients scheduled for cardiac surgery requiring central venous cannulation of the right internal jugular vein were divided into two groups: ultrasound guided group ‘U’ and the landmark group ‘L’, each consisting of 25 patients with age more than 15 years. The outcomes were compared in terms of success rate, time taken for successful cannulation and rate of complications.Results: The two groups were comparable in terms of age, weight, heart rate and blood pressure. The mean number of attempts for successful cannulation was 1.08±0.277 and 1.40±0.764 (p=0.055), the time taken in seconds for successful cannulation was 108.56±27.822 and 132.08±72.529 (p=0.137) and the overall complication rate was 0% (0 out of 25) and 32% (8 out of 25) (p=0.02) in the ultrasound guided and the landmark technique group respectively.Conclusion: Ultrasound guided central venous catheterization of internal jugular vein is comparable to the landmark technique in terms of number of attempts and the time required for successful cannulation. Ultrasound guided technique is much safer than the landmark technique to reduce the overall complications rate during central venous cannulation.


2018 ◽  
Vol 35 (9) ◽  
pp. 869-874 ◽  
Author(s):  
Jacob Bell ◽  
Munish Goyal ◽  
Sallie Long ◽  
Anagha Kumar ◽  
Joseph Friedrich ◽  
...  

Background: Central venous catheter (CVC) complication rates reflecting the application of modern insertion techniques to a clinically heterogeneous patient populations are needed to better understand procedural risk attributable to the 3 common anatomic insertion sites: internal jugular, subclavian, and femoral veins. We sought to define site-specific mechanical and duration-associated CVC complication rates across all hospital inpatients. Methods: A retrospective chart review was conducted over 9 months at Georgetown University Hospital and Washington Hospital Center. Peripherally inserted central catheters and tunneled or fluoroscopically placed CVC’s were excluded. Mechanical complications (retained guidewire, arterial injury, and pneumothorax) and duration-associated complications (deep vein thrombosis or pulmonary embolism, and central line-associated bloodstream infections) were identified. Results: In all, 1179 CVC insertions in 801 adult patients were analyzed. Approximately 32% of patients had multiple lines placed. Of 1179 CVCs, 73 total complications were recorded, giving a total rate of one or more complications occurring per CVC of 5.9%. There was no statistically significant difference between site-specific complications. A total of 19 mechanical complications were documented, with a 1.5% complication rate of one or more mechanical complications occurring. A total of 54 delayed complications were documented, with a 4.4% complication rate of 1 or more delayed complications occurring. There were no statistically significant differences between anatomic sites for either total mechanical or total delayed complications. Conclusions: These results suggest that site-specific CVC complication rates may be less common than previously reported. These data further inform on the safety of modern CVC insertion techniques across all patient populations and clinical settings.


2021 ◽  
pp. 112972982110637
Author(s):  
Nicolas Boulet ◽  
Xavier Bobbia ◽  
Antoine Gavoille ◽  
Benjamin Louart ◽  
Jean Yves Lefrant ◽  
...  

Background: Real-time ultrasound (US) guidance facilitates central venous catheterization in intensive care unit (ICU). New magnetic needle-pilot devices could improve efficiency and safety of central venous catheterization. This simulation trial was aimed at comparing venipuncture with a new needle-pilot device to conventional US technique. Methods: In a prospective, randomized, simulation trial, 51 ICU physicians and residents cannulated the right axillary vein of a human torso mannequin with standard US guidance and with a needle-pilot system, in a randomized order. The primary outcome was the time from skin puncture to successful venous cannulation. The secondary outcomes were the number of skin punctures, the number of posterior wall puncture of the axillary vein, the number of arterial punctures, the number of needle redirections, the failure rate, and the operator comfort. Results: Time to successful cannulation was shorter with needle-pilot US-guided technique (22 s (interquartile range (IQR) = 16–42) vs 25 s (IQR = 19–128); median of difference (MOD) = −9 s (95%-confidence interval (CI) −5, −22), p < 0.001). The rates of skin punctures, posterior wall puncture of axillary vein, and needle redirections were also lower ( p < 0.01). Comfort was higher in needle-pilot US-guided group on a 11-points numeric scale (8 (IQR = 8–9) vs 6 (IQR = 6–8), p < 0.001). Conclusions: In a simulation model, US-guided axillary vein catheterization with a needle-pilot device was associated with a shorter time of successful cannulation and a decrease in numbers of skin punctures and complications. The results plea for investigating clinical performance of this new device.


2018 ◽  
Vol 08 (02) ◽  
pp. 100-103 ◽  
Author(s):  
Gregory Kurkis ◽  
Albert Anastasio ◽  
Marijke DeVos ◽  
Michael Gottschalk

Background Ganglion cysts are the most frequent soft tissue tumor encountered in the upper extremity and are commonly treated by aspiration or by surgical excision. Ultrasound is a promising addition to traditional aspiration, as it allows for visualization of the needle within the ganglion before aspiration. Questions Are ganglion cysts of the wrist less likely to reoccur if they are aspirated under ultrasound guidance versus “blind” aspiration without the use of ultrasound guidance? Does patient functionality change based on whether or not the cyst recurred? Patients and Methods In total, 52 patients were successfully contacted and recurrence rates were compared between those whose cyst was treated with ultrasound-guided (13 patients) with those whose cyst was treated with blind aspiration (39 patients). Mean follow-up time was 2.9 years. Results Recurrence rates were 69% (9 patients) and 74% (29 patients) for the ultrasound-guided and blind aspiration groups, respectively (p-value: 0.73), showing no significant difference in recurrences of wrist ganglion between the two groups. A metric of functionality (Quick–DASH [Disabilities of the Arm, Shoulder, and Hand]) revealed worse outcomes in patients who experienced return of ganglion cyst after aspiration versus those who did not. Conclusion Additional studies with improved sample sizes are needed to demonstrate the superiority of ultrasound-guided aspiration versus blind aspiration. Due to a high recurrence rate following aspiration (both ultrasound-guided and blinded), a lower threshold for surgical intervention is likely reasonable. Level of Evidence This is a Level IIIb study.


Author(s):  
David Pepley ◽  
Mary Yovanoff ◽  
Katelin Mirkin ◽  
David Han ◽  
Scarlett Miller ◽  
...  

Central venous catheterization (CVC) is a medical procedure where a surgeon attempts to place a catheter in the jugular, subclavian, or femoral vein. While useful, this procedure places patients at risk of a wide variety of adverse effects. Traditionally, training is performed on CVC mannequins, but these mannequins cannot vary patient anatomy. This work describes the development of a mobile training platform utilizing a haptic robotic arm and electromagnetic tracker to simulate a CVC needle insertion. A haptic robotic arm with custom syringe attachment used force feedback to provide the feeling of a needle insertion. A virtual ultrasound environment was created and made navigable by a mock ultrasound probe containing a magnetic tracking device. The effectiveness of the system as a training tool was tested on 12 medical students without CVC experience. An average increase in successful first insertion of 4.2% per practice scenario was seen in students who trained exclusively on the robotic training device. The robotic training device was able to successfully vary the difficulty of the virtual patient scenarios which in turn affected the success rates of the medical students. These results show that this system has the potential to successfully train medical residents for future CVC insertions.


Sign in / Sign up

Export Citation Format

Share Document