scholarly journals Dose reduction potential in cone-beam CT imaging of upper extremity joints with a twin robotic x-ray system

2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Karsten Sebastian Luetkens ◽  
Süleyman Ergün ◽  
Henner Huflage ◽  
Andreas Steven Kunz ◽  
Carsten Herbert Gietzen ◽  
...  

AbstractCone-beam computed tomography is a powerful tool for 3D imaging of the appendicular skeleton, facilitating detailed visualization of bone microarchitecture. This study evaluated various combinations of acquisition and reconstruction parameters for the cone-beam CT mode of a twin robotic x-ray system in cadaveric wrist and elbow scans, aiming to define the best possible trade-off between image quality and radiation dose. Images were acquired with different combinations of tube voltage and tube current–time product, resulting in five scan protocols with varying volume CT dose indices: full-dose (FD; 17.4 mGy), low-dose (LD; 4.5 mGy), ultra-low-dose (ULD; 1.15 mGy), modulated low-dose (mLD; 0.6 mGy) and modulated ultra-low-dose (mULD; 0.29 mGy). Each set of projection data was reconstructed with three convolution kernels (very sharp [Ur77], sharp [Br69], intermediate [Br62]). Five radiologists subjectively assessed the image quality of cortical bone, cancellous bone and soft tissue using seven-point scales. Irrespective of the reconstruction kernel, overall image quality of every FD, LD and ULD scan was deemed suitable for diagnostic use in contrast to mLD (very sharp/sharp/intermediate: 60/55/70%) and mULD (0/3/5%). Superior depiction of cortical and cancellous bone was achieved in FDUr77 and LDUr77 examinations (p < 0.001) with LDUr77 scans also providing favorable bone visualization compared to FDBr69 and FDBr62 (p < 0.001). Fleiss’ kappa was 0.618 (0.594–0.641; p < 0.001), indicating substantial interrater reliability. In this study, we demonstrate that considerable dose reduction can be realized while maintaining diagnostic image quality in upper extremity joint scans with the cone-beam CT mode of a twin robotic x-ray system. Application of sharper convolution kernels for image reconstruction facilitates superior display of bone microarchitecture.

2014 ◽  
Vol 64 (12) ◽  
pp. 1907-1911
Author(s):  
Uikyu Je ◽  
Hyosung Cho ◽  
Minsik Lee ◽  
Jieun Oh ◽  
Yeonok Park ◽  
...  

2014 ◽  
Vol 41 (6Part1) ◽  
pp. 061910 ◽  
Author(s):  
Uros Stankovic ◽  
Marcel van Herk ◽  
Lennert S. Ploeger ◽  
Jan-Jakob Sonke

2003 ◽  
Author(s):  
Georg Rose ◽  
Jens Wiegert ◽  
Dirk Schaefer ◽  
Klaus Fiedler ◽  
Norbert Conrads ◽  
...  

2020 ◽  
Vol 49 (6) ◽  
pp. 20190495 ◽  
Author(s):  
Durer Iskanderani ◽  
Mats Nilsson ◽  
Per Alstergren ◽  
Xie-Qi Shi ◽  
Kristina Hellen-halme

Objective: Evaluation of cone beam CT (CBCT) examination with a low-dose scanning protocol for assessment of the temporomandibular joint (TMJ). Methods: 34 adult patients referred for CBCT imaging of the TMJ underwent two examinations with two scanning protocols, a manufacturer-recommended protocol (default) and a low-dose protocol where the tube current was reduced to 20% of the default protocol. Three image stacks were reconstructed: default protocol, low-dose protocol, and processed (using a noise reduction algorithm) low-dose protocol. Four radiologists evaluated the images. The Sign test was used to evaluate visibility of TMJ anatomic structures and image quality. Receiver operating characteristic analyzes were performed to assess the diagnostic accuracy. κ values were used to evaluate intraobserver agreement. Results: With the low-dose and processed protocols, visibility of the TMJ anatomical structures and overall image quality were comparable to the default protocol. No significant differences in radiographic findings were found for the two low-dose protocols compared to the default protocol. The area under the curves (Az) averaged for the low-dose and processed protocols, according to all observers, were 0.931 and 0.941, respectively. Intraobserver agreement was good to very good. Conclusion: For the CBCT unit used in this study, the low-dose CBCT protocol for TMJ examination was diagnostically comparable to the manufacturer-recommended protocol, but delivered a five times lower radiation dose. There is an urgent need to evaluate protocols for CBCT examinations of TMJ in order to optimize them for a radiation dose as low as diagnostically acceptable (the as low as diagnostically acceptable principle recommended by NCRP).


2020 ◽  
Vol 93 (1115) ◽  
pp. 20200412
Author(s):  
Maria Antonietta Piliero ◽  
Margherita Casiraghi ◽  
Davide Giovanni Bosetti ◽  
Simona Cima ◽  
Letizia Deantonio ◽  
...  

Objective: To evaluate the performance of low dose cone beam CT (CBCT) acquisition protocols for image-guided radiotherapy of prostate cancer. Methods: CBCT images of patients undergoing prostate cancer radiotherapy were acquired with the settings currently used in our department and two low dose settings at 50% and 63% lower exposure. Four experienced radiation oncologists and two radiation therapy technologists graded the images on five image quality characteristics. The scores were analysed through Visual Grading Regression, using the acquisition settings and the patient size as covariates. Results: The low dose acquisition settings have no impact on the image quality for patients with body profile length at hip level below 100 cm. Conclusions: A reduction of about 60% of the dose is feasible for patients with size below 100 cm. The visibility of low contrast features can be compromised if using the low dose acquisition settings for patients with hip size above 100 cm. Advances in knowledge: Low dose CBCT acquisition protocols for the pelvis, based on subjective evaluation of patient images.


2007 ◽  
Vol 34 (6Part19) ◽  
pp. 2572-2572 ◽  
Author(s):  
O Morin ◽  
M Aubin ◽  
J Aubry ◽  
S Bose ◽  
J Chen ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document