scholarly journals ORion Alma New GEneration Survey (ORANGES). I. Dust continuum and free-free emission of OMC-2/3 filament protostars

Author(s):  
M. Bouvier ◽  
A. López-Sepulcre ◽  
C. Ceccarelli ◽  
N. Sakai ◽  
S. Yamamoto ◽  
...  
Keyword(s):  
Author(s):  
D. Cherns

The use of high resolution electron microscopy (HREM) to determine the atomic structure of grain boundaries and interfaces is a topic of great current interest. Grain boundary structure has been considered for many years as central to an understanding of the mechanical and transport properties of materials. Some more recent attention has focussed on the atomic structures of metalsemiconductor interfaces which are believed to control electrical properties of contacts. The atomic structures of interfaces in semiconductor or metal multilayers is an area of growing interest for understanding the unusual electrical or mechanical properties which these new materials possess. However, although the point-to-point resolutions of currently available HREMs, ∼2-3Å, appear sufficient to solve many of these problems, few atomic models of grain boundaries and interfaces have been derived. Moreover, with a new generation of 300-400kV instruments promising resolutions in the 1.6-2.0 Å range, and resolutions better than 1.5Å expected from specialist instruments, it is an appropriate time to consider the usefulness of HREM for interface studies.


Author(s):  
Jorge Perdigao

In 1955, Buonocore introduced the etching of enamel with phosphoric acid. Bonding to enamel was created by mechanical interlocking of resin tags with enamel prisms. Enamel is an inert tissue whose main component is hydroxyapatite (98% by weight). Conversely, dentin is a wet living tissue crossed by tubules containing cellular extensions of the dental pulp. Dentin consists of 18% of organic material, primarily collagen. Several generations of dentin bonding systems (DBS) have been studied in the last 20 years. The dentin bond strengths associated with these DBS have been constantly lower than the enamel bond strengths. Recently, a new generation of DBS has been described. They are applied in three steps: an acid agent on enamel and dentin (total etch technique), two mixed primers and a bonding agent based on a methacrylate resin. They are supposed to bond composite resin to wet dentin through dentin organic component, forming a peculiar blended structure that is part tooth and part resin: the hybrid layer.


Author(s):  
S. J. Krause ◽  
W.W. Adams ◽  
S. Kumar ◽  
T. Reilly ◽  
T. Suziki

Scanning electron microscopy (SEM) of polymers at routine operating voltages of 15 to 25 keV can lead to beam damage and sample image distortion due to charging. Imaging polymer samples with low accelerating voltages (0.1 to 2.0 keV), at or near the “crossover point”, can reduce beam damage, eliminate charging, and improve contrast of surface detail. However, at low voltage, beam brightness is reduced and image resolution is degraded due to chromatic aberration. A new generation of instruments has improved brightness at low voltages, but a typical SEM with a tungsten hairpin filament will have a resolution limit of about 100nm at 1keV. Recently, a new field emission gun (FEG) SEM, the Hitachi S900, was introduced with a reported resolution of 0.8nm at 30keV and 5nm at 1keV. In this research we are reporting the results of imaging coated and uncoated polymer samples at accelerating voltages between 1keV and 30keV in a tungsten hairpin SEM and in the Hitachi S900 FEG SEM.


Author(s):  
Thomas J. Deerinck ◽  
Maryann E. Martone ◽  
Varda Lev-Ram ◽  
David P. L. Green ◽  
Roger Y. Tsien ◽  
...  

The confocal laser scanning microscope has become a powerful tool in the study of the 3-dimensional distribution of proteins and specific nucleic acid sequences in cells and tissues. This is also proving to be true for a new generation of high contrast intermediate voltage electron microscopes (IVEM). Until recently, the number of labeling techniques that could be employed to allow examination of the same sample with both confocal and IVEM was rather limited. One method that can be used to take full advantage of these two technologies is fluorescence photooxidation. Specimens are labeled by a fluorescent dye and viewed with confocal microscopy followed by fluorescence photooxidation of diaminobenzidine (DAB). In this technique, a fluorescent dye is used to photooxidize DAB into an osmiophilic reaction product that can be subsequently visualized with the electron microscope. The precise reaction mechanism by which the photooxidation occurs is not known but evidence suggests that the radiationless transfer of energy from the excited-state dye molecule undergoing the phenomenon of intersystem crossing leads to the formation of reactive oxygen species such as singlet oxygen. It is this reactive oxygen that is likely crucial in the photooxidation of DAB.


Author(s):  
S.J. Krause ◽  
W.W. Adams

Over the past decade low voltage scanning electron microscopy (LVSEM) of polymers has evolved from an interesting curiosity to a powerful analytical technique. This development has been driven by improved instrumentation and in particular, reliable field emission gun (FEG) SEMs. The usefulness of LVSEM has also grown because of an improved theoretical and experimental understanding of sample-beam interactions and by advances in sample preparation and operating techniques. This paper will review progress in polymer LVSEM and present recent results and developments in the field.In the early 1980s a new generation of SEMs produced beam currents that were sufficient to allow imaging at low voltages from 5keV to 0.5 keV. Thus, for the first time, it became possible to routinely image uncoated polymers at voltages below their negative charging threshold, the "second crossover", E2 (Fig. 1). LVSEM also improved contrast and reduced beam damage in sputter metal coated polymers. Unfortunately, resolution was limited to a few tenths of a micron due to the low brightness and chromatic aberration of thermal electron emission sources.


Author(s):  
John L. Hutchison

Over the past five years or so the development of a new generation of high resolution electron microscopes operating routinely in the 300-400 kilovolt range has produced a dramatic increase in resolution, to around 1.6 Å for “structure resolution” and approaching 1.2 Å for information limits. With a large number of such instruments now in operation it is timely to assess their impact in the various areas of materials science where they are now being used. Are they falling short of the early expectations? Generally, the manufacturers’ claims regarding resolution are being met, but one unexpected factor which has emerged is the extreme sensitivity of these instruments to both floor-borne and acoustic vibrations. Successful measures to counteract these disturbances may require the use of special anti-vibration blocks, or even simple oil-filled dampers together with springs, with heavy curtaining around the microscope room to reduce noise levels. In assessing performance levels, optical diffraction analysis is becoming the accepted method, with rotational averaging useful for obtaining a good measure of information limits. It is worth noting here that microscope alignment becomes very critical for the highest resolution.In attempting an appraisal of the contributions of intermediate voltage HREMs to materials science we will outline a few of the areas where they are most widely used. These include semiconductors, oxides, and small metal particles, in addition to metals and minerals.


VASA ◽  
2013 ◽  
Vol 42 (5) ◽  
pp. 340-349 ◽  
Author(s):  
Ivan Kralj ◽  
Irene Boos ◽  
Uwe Müller-Bühl

Background: Advances in stent technology have widened the field of indications for stent treatment of femoro-popliteal artery lesions, however the use of stents in bending arterial segments is restricted because some first- and second-generation nitinol stent designs did not respond well to the mechanical forces of femoro-popliteal segments in motion which pose a substantial risk of stent fracture inducing in-stent-stenosis. New generation nitinol stents are supposed to overcome these limitations but long-term results are rare. Patients and methods: In forty-five patients (mean age 68 y, range 50 - 85) with peripheral arterial disease (TASC II A-C, Rutherford category 2 - 5) forty-six lesions of the superficial femoral artery (37) or popliteal artery (9) were treated [25 high-grade stenoses, mean length 53 mm (range 30 - 145 mm); 21 chronic total occlusions, mean length 74 mm (range 30 - 180 mm)]. 74 % of lesions were located in the mobile bending arterial segments in the distal femoral or the popliteal segment. Clinical reevaluation performed at discharge, at 6, 12, 24, and 36 months included at least the measurement of ankle-brachial index (ABI) and duplex sonography. Results: Procedural success rate was 100 %. At 6, 12, 24, and 36 months, cumulative primary patency rate was 93.5 %, 84.8 %, 80.5 %, and 74.3 % (SE<10); freedom from target lesion revascularization rate was 95.7 %, 89.2 %, 84.9 %, and 79.3 % (SE<10); Rutherford category and ABI improved in all patients and clinical success was maintained in more than 85 % of patients. Conclusions: Sustained technical and clinical success and good clinical long-term results were achieved with Misago™ nitinol stent implantation in femoro-popliteal lesions with moderate risk for in-stent-stenosis, and in the distal femoral and popliteal mobile segment.


1994 ◽  
Vol 39 (4) ◽  
pp. 425-426
Author(s):  
Elizabeth Bull Danielson
Keyword(s):  

Sign in / Sign up

Export Citation Format

Share Document