scholarly journals Low temperature vacuum sublimation refrigerators on carbon dioxide as working fluid

2020 ◽  
Vol 324 ◽  
pp. 02004
Author(s):  
Artem Frolovich Porutchikov ◽  
Dmitriy Pavlovich Trubin

The paper presents the results of theoretical and experimental analysis of a vacuum-freeze-drying refrigeration machine based on carbon dioxide. Such refrigeration machines can be equipped with refrigerators for the needs of medicine, where low temperatures are widely in demand in the range from minus 80 degrees Celsius to minus 130 degrees Celsius. The problem of developing alternative refrigeration machines is dictated by modern environmental requirements for working substances, which are gradually being tightened and soon the use of familiar freons will become impossible. For the air conditioning and commercial refrigeration industry, new substances are being actively developed, such as hydrofluoroolefins (HFOs), hydrocarbons can also serve as substitutes for hydrofluorocarbons and their mixtures, but it must be considered that they are combustible and explosive. A carbon dioxide vacuum sublimation unit may be an alternative to modern freon vapor compression refrigeration units for the indicated temperature range, but subject to comparable energy costs during its operation. The article examined the three-stage and four-stage cycles of a vacuum-freeze-drying refrigeration machine, conducted their theoretical comparison in terms of COP with a cascade cycle on hydrocarbon working substances. It can be noted that the COP of the considered cycles are close, but the environmental friendliness, safety and non-combustibility of carbon dioxide gives the advantages of a vacuum freeze-drying refrigeration machine.

Author(s):  
Ms. K. P. Bhangle

Abstract: The capillary tube is commonly employed in refrigerant flow control systems. As a result, the capillary tube's performance is optimal for good refrigerant flow. Many scholars concluded performance utilising experimental, theoretical, and analysis-based methods. This paper examines the flow analysis of a refrigerant within a capillary tube under adiabatic flow circumstances. For a given mass flow rate, the suggested model can predict flow characteristics in adiabatic capillary tubes. In the current work, R-134a refrigerant has been replaced by R600a refrigerant as a working fluid inside the capillary tube, and the capillary tube design has been modified by altering length and diameter, which were obtained from reputable literature. The analysis is carried out using the ANSYS CFX 16.2 software. The results show thatutilising a small diameter and a long length (R600a refrigerant flow) is superior to the present helical capillary tube. The most appropriate helical coiled design with a diameter of 0.8 mm and a length of 3 m is proposed. Keywords: Capillary Tube, Condenser, Refrigeration effect, CFD.


Author(s):  
Oumayma Bounefour ◽  
Ahmed Ouadha

This paper examines through a thermodynamic analysis the feasibility of using waste heat from marine Diesel engines to drive a vapor compression refrigeration system. Several working fluids including propane, butane, isobutane and propylene are considered. Results showed that isobutane and Butane yield the highest performance, whereas propane and propylene yield negligible improvement compared to R134a for operating conditions considered.


2019 ◽  
Vol 9 (23) ◽  
pp. 5028 ◽  
Author(s):  
Pektezel ◽  
Acar

This paper presents energy and exergy analysis of two vapor compression refrigeration cycles powered by organic Rankine cycle. Refrigeration cycle of combined system was designed with single and dual evaporators. R134a, R1234ze(E), R227ea, and R600a fluids were used as working fluids in combined systems. Influences of different parameters such as evaporator, condenser, boiler temperatures, and turbine and compressor isentropic efficiencies on COPsys and ƞex,sys were analyzed. Second law efficiency, degree of thermodynamic perfection, exergy destruction rate, and exergy destruction ratio were detected for each component in systems. R600a was determined as the most efficient working fluid for proposed systems. Both COPsys and ƞex,sys of combined ORC-single evaporator VCR cycle was detected to be higher than the system with dual evaporator.


Processes ◽  
2020 ◽  
Vol 8 (9) ◽  
pp. 1017
Author(s):  
Bahaa Saleh ◽  
Ayman A. Aly ◽  
Mishal Alsehli ◽  
Ashraf Elfasakhany ◽  
Mohamed M. Bassuoni

Screening for alternative refrigerants with high energy efficiency and low environmental impacts is one of the highest challenges of the refrigeration sector. This paper investigates the performance and refrigerant screening for single and two stages vapor compression refrigeration cycles. Several pure hydrocarbons, hydrofluorocarbons, hydrofluoroolefins, fluorinated ethers, and binary azeotropic mixtures are proposed as alternative refrigerants to substitute R22 and R134a due to their environmental impacts. The BACKONE equation of state is used to compute the thermodynamic properties of the candidates. The results show that the maximum coefficients of performance (COP) for single and two stage cycles using pure substances are achieved using cyclopentane with values of 4.14 and 4.35, respectively. On the other side, the maximum COP for the two cycles using azeotropic mixtures is accomplished using R134a + RE170 with values of 3.96 and 4.27, respectively. The two-stage cycle presents gain in COP between 5.1% and 19.6% compared with the single-stage cycle based on the used refrigerant. From the obtained results, among all investigated refrigerants, cyclopentane is the most suitable refrigerant for the two cycles from the viewpoint of energy efficiency. However, extra cautions should be taken due to its flammability.


2013 ◽  
Vol 14 (1) ◽  
Author(s):  
A. B. Kasaeian ◽  
S. Daviran

In this study, a new model of a solar combined ejector-vapor compression refrigeration system has been considered. The system is equipped with an internal heat exchanger to enhance the performance of the cycle. The effects of working fluid and operating conditions on the system performance including COP, entrainment ratio (ω), compression ratio (rp) and exergy efficiency were investigated. Some working fluids suggested are: R114, R141b, R123, R245fa, R600a, R365mfc, R1234ze(e) and R1234ze(z). The results show that R114 and R1234ze(e) yield the highest COP and exergy efficiency followed by R123, R245fa, R365mfc, R141b, R152a and R600a. It is noticed that the COP value of the new solar ejector-vapor compression refrigeration cycle is higher than that of the conventional ejector cycle with R1234ze(e) for all operating conditions. This paper also demonstrates that R1234ze(e) will be a suitable refrigerant in the solar combined ejector-vapor compression refrigeration system, due to its environmental friendly properties and better performance. ABSTRAK: Kajian ini menganalisa model baru sistem penyejukan mampatan gabungan ejektor-wap solar.Sistem ini dilengkapi dengan penukar haba dalaman untuk meningkatkan prestasi kitaran.Kesan bendalir bekerja dan keadaan operasi pada prestasi sistem termasuk COP, nisbah pemerangkapan (ω), nisbah mampatan (rp) dan kecekapan eksergi telah disiasat.Beberapa bendalir bekerja yang dicadangkan adalah: R114, R141b, R123, R245fa, R600a, R365mfc, R1234ze(e) dan R1234ze(z).Hasil kajian menunjukkan R114 dan R1234ze(e) menghasilkan COP dan kecekapan eksergi tertinggi diikuti oleh R123, R245fa, R365mfc, R141b, R152a dan R600a.Didapati nilai COP kitaran penyejukan mampatan bagi ejektor-wap solar baru adalah lebih tinggi daripada kitaran ejektor konvensional dengan R1234ze(e) bagi semua keadaan operasi.Kertas kerja ini juga menunjukkan bahawa R1234ze(e) boleh menjadi penyejuk yang sesuai dalam sistem penyejukan mampatan gabungan ejektor -wap solar, kerana ianya mempunyai prestasi yang lebih baik serta sifatnya yang lebih mesra alam sekitar. KEYWORDS: environmental friendly refrigerants; solar combined ejector-vapor compression cycle; R1234ze(e)


2019 ◽  
Vol 140 ◽  
pp. 08010
Author(s):  
Alexander Kulikov ◽  
Irena Ivanova ◽  
Irina Russkova ◽  
Jaromír Veber

The features of the physical meaning of the thermal coefficient useful action (CUA) ηt as a criterion for the efficiency of reversible direct circular processes are considered. In particular, we demonstrate that accounting for all energy costs when applying ηt is made by adopting a number of assumptions by default. In order to expand the possibilities for conducting thermodynamic assessments of the efficiency of various thermal power plants, a new criterion of efficiency Ku is proposed as a coefficient that takes into account in a comparable form all types of energy spent on the implementation of the cycle. In determining the criterion Ku, useful effect obtained from the implementation of a direct circular process is considered to be the specific work of the expansion of the working fluid in the cycle. Such work, in particular, can be the work of steam expansion in the turbine. The total energy cost is the sum of the specific heat supplied to the working body in a circular process and the specific mechanical work spent in the cycle on compression and pressure increase of the working body. In particular, the work is taken into account in a comparable form-taking into account the heat that was spent on its production. The analysis of the Ku criterion is carried out. As a result of the analysis we have established that at transition from the general physical model of reception of specific work of expansion in direct circular process for which Ku criterion can be applied, to the special case assuming a number of assumptions, Ku criterion can become equal to thermal coefficient useful action of a cycle. Using the Ku criterion, the efficiency of Carnot and Rankine cycles on a saturated pair is compared. The Ku score showed that the Rankine cycle was more efficient.


Sign in / Sign up

Export Citation Format

Share Document