Analysis of three-dimensional in vivo knee kinematics using dynamic magnetic resonance imaging

2005 ◽  
Vol 15 (1) ◽  
pp. 57-63 ◽  
Author(s):  
C. Benjamin Ma ◽  
Keh-yang Lee ◽  
Mark A. Schrumpf ◽  
Sharmila Majumdar
2001 ◽  
Vol 49 (3) ◽  
pp. 275-284
Author(s):  
Zs. Petrási ◽  
R. Romvári ◽  
G. Bajzik ◽  
B. Fenyves ◽  
I. Repa ◽  
...  

A dynamic magnetic resonance imaging (MRI) method was developed for in vivo examination of the pig heart. Measurements were carried out on 15 meat-type pigs of different liveweight using a 1.5 T equipment. Inhalation anaesthesia was applied, then data acquisition was synchronised by ECG gating. Depending on the heart rate and heart size, in each case 8 to 10 slices and in each slice 8 to 14 phases were acquired prospectively according to one heart cycle. During the post-processing of the images the left and the right ventricular volumes were determined. The values measured at 106 kg liveweight are 2.5 times higher than those obtained at 22 kg, while the ejection fractions are equal. The calculated cardiac output values were 3.5 l (22 kg, 132 beats/min.), and 6.0 l (106 kg, 91 beats/min.), respectively. After measuring the wall thickness, the contraction values were also determined for the septum (70%), and for the anterior (61%), posterior (41%) and lateral (54%) walls of the left ventricle. Three-dimensional animated models of the ventricles were constructed. Based on the investigations performed, the preconditioning, the anaesthetic procedure, the specific details of ECG measurement and the correct MR imaging technique were worked out.


Author(s):  
Tracy L. Rausch ◽  
Beth A. Wirick ◽  
Steven J. Stanhope ◽  
Frances T. Sheehan

In order to take advantage of the opportunities that dynamic Magnetic Resonance Imaging (d-MRI) offers to the study of in vivo joint mechanics, d-MRI compatible devices capable of producing joint loads replicating dynamic physiological activities are needed (Sheehan et al., 1999). The purpose of this research effort was to design, model and test a device for the expressed purpose of using d-MRI to study precise ankle joint dynamics during loaded pseudo-functional movements. The device adjusts to subject specific anthropometric measurements, allowing for the device’s axis of rotation to approximate the ankle’s transverse axis. By combining imaging data and the model of the device, the magnitude, direction and point of application of the force applied to the foot were calculated throughout the motion cycle, with an average error of .7 Nm. This allows for comparisons between the externally applied load and internal ankle joint kinematics to be made, which are essential determinants for in vivo estimates of forces within tendon and ligament. The next phase of this work will be to combine this device with fast-Phase Contrast MRI (fast-pc), a previously developed d-MRI technique for the quantification of 3D musculoskeletal motion, in order to create a complete tool for the noninvasive in vivo measurement of joint kinematics during a loaded dynamic functional task in both healthy and impaired ankles.


2019 ◽  
Vol 86 ◽  
pp. 193-203 ◽  
Author(s):  
Karim Makki ◽  
Bhushan Borotikar ◽  
Marc Garetier ◽  
Sylvain Brochard ◽  
Douraied Ben Salem ◽  
...  

Strain ◽  
2020 ◽  
Vol 56 (3) ◽  
Author(s):  
H. Courtecuisse ◽  
Z. Jiang ◽  
O. Mayeur ◽  
J. F. Witz ◽  
P. Lecomte‐Grosbras ◽  
...  

2020 ◽  
Vol 10 (1) ◽  
pp. 14
Author(s):  
Cezary Grochowski ◽  
Kamil Jonak ◽  
Marcin Maciejewski ◽  
Andrzej Stępniewski ◽  
Mansur Rahnama-Hezavah

Purpose: The aim of this study was to assess the volumetry of the hippocampus in the Leber’s hereditary optic neuropathy (LHON) of blind patients. Methods: A total of 25 patients with LHON were randomly included into the study from the national health database. A total of 15 patients were selected according to the inclusion criteria. The submillimeter segmentation of the hippocampus was based on three-dimensional spoiled gradient recalled acquisition in steady state (3D-SPGR) BRAVO 7T magnetic resonance imaging (MRI) protocol. Results: Statistical analysis revealed that compared to healthy controls (HC), LHON subjects had multiple significant differences only in the right hippocampus, including a significantly higher volume of hippocampal tail (p = 0.009), subiculum body (p = 0.018), CA1 body (p = 0.002), hippocampal fissure (p = 0.046), molecular layer hippocampus (HP) body (p = 0.014), CA3 body (p = 0.006), Granule Cell (GC) and Molecular Layer (ML) of the Dentate Gyrus (DG)–GC ML DG body (p = 0.003), CA4 body (p = 0.001), whole hippocampal body (p = 0.018), and the whole hippocampus volume (p = 0.023). Discussion: The ultra-high-field magnetic resonance imaging allowed hippocampus quality visualization and analysis, serving as a powerful in vivo diagnostic tool in the diagnostic process and LHON disease course assessment. The study confirmed previous reports regarding volumetry of hippocampus in blind individuals.