Heart failure and implantable cardioverter defibrillator (ICD) therapy: Update and perspective on current primary prevention trials

2002 ◽  
Vol 8 (3) ◽  
pp. 161-166 ◽  
Author(s):  
Leslie A. Saxon
Author(s):  
Victor Nauffal ◽  
Peter Marstrand ◽  
Larry Han ◽  
Victoria N Parikh ◽  
Adam S Helms ◽  
...  

Abstract Aims  Risk stratification algorithms for sudden cardiac death (SCD) in hypertrophic cardiomyopathy (HCM) and regional differences in clinical practice have evolved over time. We sought to compare primary prevention implantable cardioverter defibrillator (ICD) implantation rates and associated clinical outcomes in US vs. non-US tertiary HCM centres within the international Sarcomeric Human Cardiomyopathy Registry. Methods and results We included patients with HCM enrolled from eight US sites (n = 2650) and five non-US (n = 2660) sites and used multivariable Cox-proportional hazards models to compare outcomes between sites. Primary prevention ICD implantation rates in US sites were two-fold higher than non-US sites (hazard ratio (HR) 2.27 [1.89–2.74]), including in individuals deemed at high 5-year SCD risk (≥6%) based on the HCM risk-SCD score (HR 3.27 [1.76–6.05]). US ICD recipients also had fewer traditional SCD risk factors. Among ICD recipients, rates of appropriate ICD therapy were significantly lower in US vs. non-US sites (HR 0.52 [0.28–0.97]). No significant difference was identified in the incidence of SCD/resuscitated cardiac arrest among non-recipients of ICDs in US vs. non-US sites (HR 1.21 [0.74–1.97]). Conclusion  Primary prevention ICDs are implanted more frequently in patients with HCM in US vs. non-US sites across the spectrum of SCD risk. There was a lower rate of appropriate ICD therapy in US sites, consistent with a lower-risk population, and no significant difference in SCD in US vs. non-US patients who did not receive an ICD. Further studies are needed to understand what drives malignant arrhythmias, optimize ICD allocation, and examine the impact of different ICD utilization strategies on long-term outcomes in HCM.


Circulation ◽  
2018 ◽  
Vol 138 (24) ◽  
pp. 2787-2797 ◽  
Author(s):  
Andrew P. Ambrosy ◽  
Craig S. Parzynski ◽  
Daniel J. Friedman ◽  
Marat Fudim ◽  
Adrian F. Hernandez ◽  
...  

2021 ◽  
Vol 11 (1) ◽  
pp. 121
Author(s):  
Marco Canepa ◽  
Pietro Palmisano ◽  
Gabriele Dell’Era ◽  
Matteo Ziacchi ◽  
Ernesto Ammendola ◽  
...  

The role of prognostic risk scores in predicting the competing risk of non-sudden death in heart failure patients with reduced ejection fraction (HFrEF) receiving an implantable cardioverter-defibrillator (ICD) is unclear. To this goal, we evaluated the accuracy and usefulness of the Meta-Analysis Global Group in Chronic Heart Failure (MAGGIC) score. The present analysis included 1089 HFrEF ICD recipients enrolled in the OBSERVO-ICD registry (NCT02735811). During a median follow-up of 36 months (1st–3rd IQR 25–48 months), 193 patients (17.7%) experienced at least one appropriate ICD therapy, and 133 patients died (12.2%) without experiencing any ICD therapy. The frequency of patients receiving ICD therapies was stable around 17–19% across increasing tertiles of 3-year MAGGIC probability of death, whereas non-sudden mortality increased (6.4% to 9.8% to 20.8%, p < 0.0001). Accuracy of MAGGIC score was 0.60 (95% CI, 0.56–0.64) for the overall outcome, 0.53 (95% CI, 0.49–0.57) for ICD therapies and 0.65 (95% CI, 0.60–0.70) for non-sudden death. In patients with higher 3-year MAGGIC probability of death, the increase in the competing risk of non-sudden death during follow-up was greater than that of receiving an appropriate ICD therapy. Results were unaffected when analysis was limited to ICD shocks only. The MAGGIC risk score proved accurate and useful in predicting the competing risk of non-sudden death in HFrEF ICD recipients. Estimation of mortality risk should be taken into greater consideration at the time of ICD implantation.


2019 ◽  
Vol 19 (1) ◽  
Author(s):  
You Zhou ◽  
Shuang Zhao ◽  
Keping Chen ◽  
Wei Hua ◽  
Yangang Su ◽  
...  

Abstract Background Because of previous ventricular arrhythmia (VA) episodes, patients with implantable cardioverter-defibrillator (ICD) for secondary prevention (SP) are generally considered to have a higher burden of VAs than primary prevention (PP) patients. However, when PP patients experienced VA, the difference in the prognosis of these two patient groups was unknown. Methods The clinical characteristics and follow-up data of 835 ICD patients (364 SP patients and 471 PP patients) with home monitoring feature were retrospectively analysed. The incidence rate and risk of subsequent VA and all-cause mortality were compared between PP patients after the first appropriate ICD therapy and SP patients. Results During a mean follow-up of 44.72 ± 20.87 months, 210 (44.59%) PP patients underwent appropriate ICD therapy. In the Kaplan-Meier survival analysis, the PP patients after appropriate ICD therapy were more prone to VA recurrence and all-cause mortality than SP patients (P<0.001 for both endpoints). The rate of appropriate ICD therapy and all-cause mortality in PP patients after the first appropriate ICD therapy was significantly higher than that in SP patients (for device therapy, 59.46 vs 20.64 patients per 100 patient-years; incidence rate ratio [IRR] 2.880, 95% confidence interval [CI]: 2.305–3.599; P<0.001; for all-cause mortality, 14.08 vs 5.40 deaths per 100 patient-years; IRR 2.607, 95% CI: 1.884–3.606; P<0.001). After propensity score matching for baseline characteristics, the risk of VA recurrence in PP patients with appropriate ICD therapy was still higher than that in SP patients (41.80 vs 19.10 patients per 100 patient-years; IRR 2.491, 95% CI: 1.889–3.287; P<0.001), but all-cause mortality rates were similar between the two groups (12.61 vs 9.33 deaths per 100 patient-years; IRR 1.352, 95% CI: 0.927–1.972; P = 0.117). Conclusions Once PP patients undergo appropriate ICD therapy, they will be more prone to VA recurrence and death than SP patients.


2020 ◽  
Vol 41 (Supplement_2) ◽  
Author(s):  
V Waldmann ◽  
A Bouzeman ◽  
G Duthoit ◽  
R Koutbi ◽  
F Bessiere ◽  
...  

Abstract Background Tetralogy of Fallot (TOF) is the most common cyanotic congenital heart disease, and sudden cardiac death represents an important mode of death in these patients. Data evaluating the implantable cardioverter defibrillator (ICD) in this patient population remain scarce. Purpose We aimed to describe long-term follow-up of patients with TOF and ICD through a large nationwide registry. Methods Nationwide Registry including all TOF patients with an ICD initiated in 2010. The primary outcome was the first appropriate ICD therapy. Secondary outcomes included ICD-related complications, heart transplantation, and death. Clinical events were centrally adjudicated by a blinded committee. Cox proportional hazard models were used to identify predictors of appropriate ICD therapies and ICD-related complications. Results A total of 165 patients (mean age 42.2±13.3 years, 70.1% males) were included from 40 centers, including 104 (63.0%) in secondary prevention. During a median (IQR) follow-up of 6.8 (2.5–11.4) years, 78 (47.3%) patients received at least one appropriate ICD therapy, giving an annual incidence of 10.5% (7.1% and 12.5% in primary and secondary prevention, respectively, p=0.03). Overall, 71 (43.0%) patients presented with at least one complication, including inappropriate ICD shocks in 42 (25.5%) patients and lead/generator dysfunction in 36 (21.8%) patients. Among 61 (37.0%) primary prevention patients, the annual rate of appropriate ICD therapies was 4.1%, 5.3%, 9.5%, and 13.3% in patients with respectively no, one, two, or ≥ three guideline-recommended risk factors. In our cohort, QRS fragmentation was the only independent predictor of appropriate ICD therapies (HR 4.34, 95% CI 1.42–13.23), and its integration in a model with current criteria increased the area under the curve from 0.61 to 0.72 (p=0.006). No patient with left ventricular ejection fraction (LVEF) ≤35% without at least one other risk factor had appropriate ICD therapy. Patients with congestive heart failure and/or reduced LVEF had a higher risk of non-sudden death or heart transplantation (HR=11.01, 95% CI: 2.96–40.95). Conclusions Our findings demonstrate high rates of appropriate therapies in TOF patients with an ICD, including in primary prevention. The considerable long-term burden of ICD-related complications, however, underlines the need for careful candidate selection. A combination of easy-to-use criteria might improve risk stratification beyond low LVEF. Freedom from appropriate ICD therapy Funding Acknowledgement Type of funding source: None


Sign in / Sign up

Export Citation Format

Share Document