Prospective, Randomized Clinical Trial Comparing a Novel Motion-Assistive Device to Standard Physical Therapy for Initial Management of Knee Range of Motion after Primary Total Knee Arthroplasty

Author(s):  
James L. Cook ◽  
Kylee Rucinski ◽  
Cory R. Crecelius ◽  
Suzin Cunningham ◽  
Trent M. Guess

AbstractThis prospective randomized clinical trial assessed a novel device for initial management of knee range of motion (ROM), pain, and function after total knee arthroplasty (TKA). Primary TKA patients with preoperative ROM of at least 5° to 115° were randomized to initial knee motion management: Mizzou BioJoint Flex—novel motion-assistive device with prescribed physical therapy or standard physical therapy—prescribed physical therapy. ROM, pain score, and knee injury and osteoarthritis score for joint replacement (KOOSjr) were obtained preoperatively and 2 weeks, 6 weeks, and 3 months postoperatively. Patient satisfaction for both cohorts and subjective assessments of the MBF device were assessed at 3 months. Readmissions, reoperations, and complications were assessed through 1 year. Nineteen patients were randomized to each cohort, with no significant preoperative differences in demographics, pain score, KOOSjr score, or ROM. Six SPT (31.6%) and 3 MBF (15.8%) patients failed to regain preoperative ROM (p = 0.044). One SPT (5.3%) and eight MBF (42%) patients exceeded 125° ROM (p = 0.019) by 3 months. Total ROM (p = 0.039), pain (p = 0.0068), and function (p = 0.0027) were significantly better for MBF at 3 months. MBF patients reported significantly higher satisfaction (mean, 9.4 ± 1.1 vs. 8.0 ± 1.8, respectively; p = 0.0084). One patient in each group underwent manipulation under anesthesia. No other readmissions, reoperations, or complications were reported. A novel durable medical equipment device can provide a safe and effective patient-controlled method for initial management of knee ROM, pain, and function after primary TKA with potential clinically meaningful advantages over physical therapy alone. In conjunction with physical therapy, management with this novel knee flexion device more effectively restored knee ROM and early patient function when compared with therapy alone and was associated with higher proportions of patients regaining minimum (115°) and desired (125°) levels of knee ROM and clinically meaningful differences in pain scores, knee function, and patient satisfaction. This is a Level 1, prospective trial study.

2021 ◽  
Vol 103-B (1) ◽  
pp. 105-112 ◽  
Author(s):  
Joseph T. Lynch ◽  
Diana M. Perriman ◽  
Jennie M. Scarvell ◽  
Mark R. Pickering ◽  
Catherine R. Galvin ◽  
...  

Aims Modern total knee arthroplasty (TKA) prostheses are designed to restore near normal kinematics including high flexion. Kneeling is a high flexion, kinematically demanding activity after TKA. The debate about design choice has not yet been informed by six-degrees-of-freedom in vivo kinematics. This prospective randomized clinical trial compared kneeling kinematics in three TKA designs. Methods In total, 68 patients were randomized to either a posterior stabilized (PS-FB), cruciate-retaining (CR-FB), or rotating platform (CR-RP) design. Of these patients, 64 completed a minimum one year follow-up. Patients completed full-flexion kneeling while being imaged using single-plane fluoroscopy. Kinematics were calculated by registering the 3D implant models onto 2D-dynamic fluoroscopic images and exported for analysis. Results CR-FB designs had significantly lower maximal flexion (mean 116° (SD 2.1°)) compared to CR-RP (123° (SD 1.6°)) and PS-FB (125° (SD 2.1°)). The PS-FB design displayed a more posteriorly positioned femur throughout flexion. Furthermore, the CR-RP femur was more externally rotated throughout kneeling. Finally, individual patient kinematics showed high degrees of variability within all designs. Conclusion The increased maximal flexion found in the PS-FB and CR-RP designs were likely achieved in different ways. The PS-FB design uses a cam-post to hold the femur more posteriorly preventing posterior impingement. The external rotation within the CR-RP design was surprising and hasn’t previously been reported. It is likely due to the polyethylene bearing being decoupled from flexion. The findings of this study provide insights into the function of different knee arthroplasty designs in the context during deep kneeling and provide clinicians with a more kinematically informed choice for implant selection and may allow improved management of patients' functional expectations. Cite this article: Bone Joint J 2021;103-B(1):105–112.


Author(s):  
Michael McAuliffe ◽  
Patrick O'Connor ◽  
Lisa Major ◽  
Gautam Garg ◽  
Sarah L. Whitehouse ◽  
...  

AbstractSoft tissue balancing, while accepted as crucial to total knee arthroplasty (TKA) outcomes, is incompletely defined as the subject of broad recommendations. We analyzed 120 computer-assisted, posterior stabilized TKA undertaken for osteoarthritis. Coronal plane laxity was measured, in the 91 varus and 29 valgus knees, prior to any bone resection or soft tissue release, and again after implant insertion. Soft tissue laxity parameters were correlated to the American Knee Society Score (2011) at a minimum follow-up of 12 months with a focus on patient function and satisfaction. Thirteen specific laxity parameters showed a significant correlation to satisfaction, one parameter correlated to function, and another to both functional and satisfaction outcomes. Most correlations were weak, the strongest related to postoperative decreases in coronal plane laxity. Greater preoperative varus but not valgus deformity was associated with higher satisfaction scores. Additionally, 30 patients who reported 40 of 40 satisfaction and that their TKA knee felt normal at all times did not have soft tissue balancing parameters distinguishing them from other subjects. Patient satisfaction and function outcomes demonstrated limited correlation to coronal plane soft tissue parameters. It appears that optimizing TKA satisfaction and function is not as simple as producing a narrow range of coronal laxity parameters. The ongoing debate around optimal coronal plane alignment and its subsequent effect on coronal plane soft tissues may not be as independently important as currently argued. Soft tissue balance may need to be considered as a more complex global envelope.


2017 ◽  
Vol 7 (3) ◽  
Author(s):  
Justin M Head ◽  
Ryan Nelson ◽  
Mark Dyball ◽  
Bruce D Lawrence

Background: Patellar resurfacing in total knee arthroplasty remains a point of controversy within the literature and the generally followed paradigm varies among regions.Methods: In effort to elucidate a difference following the change from universal patellar resurfacing to universal non-resurfacing, 32 patients with bilateral TKA that included one resurfaced and one native patella were retrospectively reviewed at average follow up 21.4 months from the most recent surgery.Results: No difference was observed in patient satisfaction, KOOS-ADL score, and VAS scores. No complications or secondary patellar resurfacing occurred.Conclusions: Therefore, patients perceive no difference between knees with native patella retention or a resurfaced patella in regards to pain and function.


Sign in / Sign up

Export Citation Format

Share Document