Effect of an Electronic Water Treatment System on Calcium Carbonate Scaling: A Case Study

Author(s):  
Bishow N. Shaha ◽  
Daniel E. Meeroff ◽  
Kevin Kohn
2019 ◽  
Vol 145 (9) ◽  
pp. 04019052 ◽  
Author(s):  
Bishow N. Shaha ◽  
Daniel E. Meeroff ◽  
Kevin Kohn ◽  
Timothy G. Townsend ◽  
John D. Schert ◽  
...  

Author(s):  
Yehia F. Khalil ◽  
Menachem Elimelech

In this work, we describe a novel design that utilizes seawater and a portion of rejected heat from a nuclear plant’s steam cycle to operate a water desalination system using forward osmosis technology. Water produced from this process is of sufficient quality to be readily used to supply plant demands for continuous makeup water. The proposed process minimizes the environmental concerns associated with thermal pollution of public waters and the resulting adverse impact on marine ecology. To demonstrate the technical feasibility of this conceptual design of a water treatment process, we discuss a case study as an example to describe how the proposed design can be implemented in a nuclear power station with a once–through cooling system that discharges rejected heat to an open sound seawater as its ultimate heat sink. In this case study, the station uses a leased (vendor owned and operated) onsite water treatment system that demineralizes and polishes up to 500-gpm of city water (at 100 ppm TDS) to supply high-quality makeup water (< 0.01 ppm TDS) to the plant steam system. The objectives of implementing the new design are three fold: 1) forego current practice of using city water as the source of plant makeup water, thereby reducing the nuclear station’s impact on the region’s potable water supply by roughly 100 million gallons/year, 2) minimize the adverse impact of discharging rejected heat into the open sound seawater and, hence, protect the marine ecology, and 3) eliminate the reliance on external vendor that owns and operates the onsite water treatment system, thereby saving an annual fixed cost of $600K plus 6 cents per 1,000 gallons of pure water. The design will also eliminate the need for using two double-path reverse osmosis (RO) units that consume 425 kW/h of electric power to operate two RO pumps (480V, 281.6 HP, and 317.4 amps).


2018 ◽  
Vol 18 (1) ◽  
pp. 107-115 ◽  
Author(s):  
Kwang-Hee Lee ◽  
◽  
Min-Ho Kim ◽  
Nam-Woo An ◽  
Chul-hwi Park

1988 ◽  
Vol 20 (11-12) ◽  
pp. 117-123 ◽  
Author(s):  
D. van der Kooij ◽  
W. A. M. Hijnen

A K.pneumoniae strain, isolated from a water treatment system, was tested in growth measurements for its ability to multiply at substrate concentrations of a few micrograms per liter. The organism multiplied on mixtures of carbohydrates and amino acids at a substrate concentration of 1 µg of C of each compound per liter. Tests with individual compounds revealed that especially carbohydrates were utilized at low concentrations. The Ks values obtained for maltose and maltopentaose were 53 µg of C/l and 114 µg of C per liter, respectively. The significance of the growth of K.pneumoniae at low substrate concentrations is discussed.


Author(s):  
Hongsik Yoon ◽  
Jiho Lee ◽  
Taijin Min ◽  
Gunhee Lee ◽  
Minsub Oh

Capacitive deionization (CDI) has been highlighted as a promising electrochemical water treatment system. However, the low deionization capacity of CDI electrodes has been a major limitation for its industrial application,...


RSC Advances ◽  
2021 ◽  
Vol 11 (32) ◽  
pp. 19788-19796
Author(s):  
Bramha Gupta ◽  
Rushikesh S. Ambekar ◽  
Raphael M. Tromer ◽  
Partha Sarathi Ghosal ◽  
Rupal Sinha ◽  
...  

The impact of micro and nanoplastic debris on our aquatic ecosystem is among the most prominent environmental challenges we face today.


Sign in / Sign up

Export Citation Format

Share Document