A self-paced brain–computer interface system with a low false positive rate

2007 ◽  
Vol 5 (1) ◽  
pp. 9-23 ◽  
Author(s):  
M Fatourechi ◽  
R K Ward ◽  
G E Birch
Sensors ◽  
2021 ◽  
Vol 21 (13) ◽  
pp. 4578
Author(s):  
Jihyeon Ha ◽  
Sangin Park ◽  
Chang-Hwan Im ◽  
Laehyun Kim

Assistant devices such as meal-assist robots aid individuals with disabilities and support the elderly in performing daily activities. However, existing meal-assist robots are inconvenient to operate due to non-intuitive user interfaces, requiring additional time and effort. Thus, we developed a hybrid brain–computer interface-based meal-assist robot system following three features that can be measured using scalp electrodes for electroencephalography. The following three procedures comprise a single meal cycle. (1) Triple eye-blinks (EBs) from the prefrontal channel were treated as activation for initiating the cycle. (2) Steady-state visual evoked potentials (SSVEPs) from occipital channels were used to select the food per the user’s intention. (3) Electromyograms (EMGs) were recorded from temporal channels as the users chewed the food to mark the end of a cycle and indicate readiness for starting the following meal. The accuracy, information transfer rate, and false positive rate during experiments on five subjects were as follows: accuracy (EBs/SSVEPs/EMGs) (%): (94.67/83.33/97.33); FPR (EBs/EMGs) (times/min): (0.11/0.08); ITR (SSVEPs) (bit/min): 20.41. These results revealed the feasibility of this assistive system. The proposed system allows users to eat on their own more naturally. Furthermore, it can increase the self-esteem of disabled and elderly peeople and enhance their quality of life.


Author(s):  
Vidya K. Nandikolla ◽  
Travis Van Leeuwen

Abstract A brain–computer interface (BCI)-based controller bridges the gap between smart wheelchairs and physically impaired persons with severe conditions. This paper presents the design of a hybrid BCI controller with six classifiers using an electroencephalogram (EEG) headset to detect hand motor imagery (MI) and jaw electromyography (EMG) signals. A BCI controller and semi-autonomous system is developed to control a smart wheelchair in conjunction with its semi-autonomous capabilities. For data acquisition, an openvibe system and a commercial grade EEG headset are used. A multiple common spatial pattern (CSP) filter and Linear discriminant analysis (LDA) classifier system is used to process and classify the user's brain activity. To convert the classifier data into a signal that is compatible with the semi-autonomous wheelchair system, a fuzzy logic controller (FLC) is integrated in LabVIEW. Subjects are trained to use the BCI system and the classifier profiles are optimized for each user and the results are analyzed for this study. The openvibe “Replay” script and recorded training data are used to evaluate the performance of the controller scheme. For each subject, positive, negative, and false-positive executions are recorded. During the initial testing phase, the positive rates for subjects were strong, but false-positive rates were too high to be used. Therefore, the design is iterated by changing the rules of the FLC and configuration of the LabVIEW script. The configuration with the best positive rates for turn executions is chosen where the average positive rate for turning is 0.68 for subject 1 and 0.64 for subject 2.


2007 ◽  
Vol 2007 ◽  
pp. 1-8 ◽  
Author(s):  
Ali Bashashati ◽  
Rabab K. Ward ◽  
Gary E. Birch

Most existing brain-computer interfaces (BCIs) detect specific mental activity in a so-called synchronous paradigm. Unlike synchronous systems which are operational at specific system-defined periods, self-paced (asynchronous) interfaces have the advantage of being operational at all times. The low-frequency asynchronous switch design (LF-ASD) is a 2-state self-paced BCI that detects the presence of a specific finger movement in the ongoing EEG. Recent evaluations of the 2-state LF-ASD show an average true positive rate of 41% at the fixed false positive rate of 1%. This paper proposes two designs for a 3-state self-paced BCI that is capable of handling idle brain state. The two proposed designs aim at detecting right- and left-hand extensions from the ongoing EEG. They are formed of two consecutive detectors. The first detects the presence of a right- or a left-hand movement and the second classifies the detected movement as a right or a left one. In an offline analysis of the EEG data collected from four able-bodied individuals, the 3-state brain-computer interface shows a comparable performance with a 2-state system and significant performance improvement if used as a 2-state BCI, that is, in detecting the presence of a right- or a left-hand movement (regardless of the type of movement). It has an average true positive rate of 37.5% and 42.8% (at false positives rate of 1%) in detecting right- and left-hand extensions, respectively, in the context of a 3-state self-paced BCI and average detection rate of 58.1% (at false positive rate of 1%) in the context of a 2-state self-paced BCI.


2002 ◽  
Vol 41 (01) ◽  
pp. 37-41 ◽  
Author(s):  
S. Shung-Shung ◽  
S. Yu-Chien ◽  
Y. Mei-Due ◽  
W. Hwei-Chung ◽  
A. Kao

Summary Aim: Even with careful observation, the overall false-positive rate of laparotomy remains 10-15% when acute appendicitis was suspected. Therefore, the clinical efficacy of Tc-99m HMPAO labeled leukocyte (TC-WBC) scan for the diagnosis of acute appendicitis in patients presenting with atypical clinical findings is assessed. Patients and Methods: Eighty patients presenting with acute abdominal pain and possible acute appendicitis but atypical findings were included in this study. After intravenous injection of TC-WBC, serial anterior abdominal/pelvic images at 30, 60, 120 and 240 min with 800k counts were obtained with a gamma camera. Any abnormal localization of radioactivity in the right lower quadrant of the abdomen, equal to or greater than bone marrow activity, was considered as a positive scan. Results: 36 out of 49 patients showing positive TC-WBC scans received appendectomy. They all proved to have positive pathological findings. Five positive TC-WBC were not related to acute appendicitis, because of other pathological lesions. Eight patients were not operated and clinical follow-up after one month revealed no acute abdominal condition. Three of 31 patients with negative TC-WBC scans received appendectomy. They also presented positive pathological findings. The remaining 28 patients did not receive operations and revealed no evidence of appendicitis after at least one month of follow-up. The overall sensitivity, specificity, accuracy, positive and negative predictive values for TC-WBC scan to diagnose acute appendicitis were 92, 78, 86, 82, and 90%, respectively. Conclusion: TC-WBC scan provides a rapid and highly accurate method for the diagnosis of acute appendicitis in patients with equivocal clinical examination. It proved useful in reducing the false-positive rate of laparotomy and shortens the time necessary for clinical observation.


1993 ◽  
Vol 32 (02) ◽  
pp. 175-179 ◽  
Author(s):  
B. Brambati ◽  
T. Chard ◽  
J. G. Grudzinskas ◽  
M. C. M. Macintosh

Abstract:The analysis of the clinical efficiency of a biochemical parameter in the prediction of chromosome anomalies is described, using a database of 475 cases including 30 abnormalities. A comparison was made of two different approaches to the statistical analysis: the use of Gaussian frequency distributions and likelihood ratios, and logistic regression. Both methods computed that for a 5% false-positive rate approximately 60% of anomalies are detected on the basis of maternal age and serum PAPP-A. The logistic regression analysis is appropriate where the outcome variable (chromosome anomaly) is binary and the detection rates refer to the original data only. The likelihood ratio method is used to predict the outcome in the general population. The latter method depends on the data or some transformation of the data fitting a known frequency distribution (Gaussian in this case). The precision of the predicted detection rates is limited by the small sample of abnormals (30 cases). Varying the means and standard deviations (to the limits of their 95% confidence intervals) of the fitted log Gaussian distributions resulted in a detection rate varying between 42% and 79% for a 5% false-positive rate. Thus, although the likelihood ratio method is potentially the better method in determining the usefulness of a test in the general population, larger numbers of abnormal cases are required to stabilise the means and standard deviations of the fitted log Gaussian distributions.


2019 ◽  
Author(s):  
Amanda Kvarven ◽  
Eirik Strømland ◽  
Magnus Johannesson

Andrews & Kasy (2019) propose an approach for adjusting effect sizes in meta-analysis for publication bias. We use the Andrews-Kasy estimator to adjust the result of 15 meta-analyses and compare the adjusted results to 15 large-scale multiple labs replication studies estimating the same effects. The pre-registered replications provide precisely estimated effect sizes, which do not suffer from publication bias. The Andrews-Kasy approach leads to a moderate reduction of the inflated effect sizes in the meta-analyses. However, the approach still overestimates effect sizes by a factor of about two or more and has an estimated false positive rate of between 57% and 100%.


Electronics ◽  
2020 ◽  
Vol 9 (11) ◽  
pp. 1894
Author(s):  
Chun Guo ◽  
Zihua Song ◽  
Yuan Ping ◽  
Guowei Shen ◽  
Yuhei Cui ◽  
...  

Remote Access Trojan (RAT) is one of the most terrible security threats that organizations face today. At present, two major RAT detection methods are host-based and network-based detection methods. To complement one another’s strengths, this article proposes a phased RATs detection method by combining double-side features (PRATD). In PRATD, both host-side and network-side features are combined to build detection models, which is conducive to distinguishing the RATs from benign programs because that the RATs not only generate traffic on the network but also leave traces on the host at run time. Besides, PRATD trains two different detection models for the two runtime states of RATs for improving the True Positive Rate (TPR). The experiments on the network and host records collected from five kinds of benign programs and 20 famous RATs show that PRATD can effectively detect RATs, it can achieve a TPR as high as 93.609% with a False Positive Rate (FPR) as low as 0.407% for the known RATs, a TPR 81.928% and FPR 0.185% for the unknown RATs, which suggests it is a competitive candidate for RAT detection.


Sign in / Sign up

Export Citation Format

Share Document