scholarly journals Compensation for the Temperature Dependence of the Fog Output Signal

2022 ◽  
Vol 1215 (1) ◽  
pp. 012003
Author(s):  
D.A. Gontar ◽  
E.V. Dranitsyna

Abstract This paper proposes a method for compensating the temperature error in the FOG output signal using neural networks. One of the main advantages of the method lies in possibility for identification of complex dependencies without losing compensation accuracy at the boundaries of the temperature range.

Author(s):  
Peter P. Knox ◽  
Vladimir V. Gorokhov ◽  
Boris N. Korvatovsky ◽  
Nadezhda P. Grishanova ◽  
Sergey N. Goryachev ◽  
...  

Sensors ◽  
2021 ◽  
Vol 21 (5) ◽  
pp. 1700
Author(s):  
Anca Mihaela Vasile (Dragan) ◽  
Alina Negut ◽  
Adrian Tache ◽  
Gheorghe Brezeanu

An EEPROM (electrically erasable programmable read-only memory) reprogrammable fuse for trimming a digital temperature sensor is designed in a 0.18-µm CMOS EEPROM. The fuse uses EEPROM memory cells, which allow multiple programming cycles by modifying the stored data on the digital trim codes applied to the thermal sensor. By reprogramming the fuse, the temperature sensor can be adjusted with an increased trim variation in order to achieve higher accuracy. Experimental results for the trimmed digital sensor showed a +1.5/−1.0 ℃ inaccuracy in the temperature range of −20 to 125 ℃ for 25 trimmed DTS samples at 1.8 V by one-point calibration. Furthermore, an average mean of 0.40 ℃ and a standard deviation of 0.70 ℃ temperature error were obtained in the same temperature range for power supply voltages from 1.7 to 1.9 V. Thus, the digital sensor exhibits similar performances for the entire power supply range of 1.7 to 3.6 V.


1978 ◽  
Vol 31 (4) ◽  
pp. 791 ◽  
Author(s):  
R Chandramani ◽  
SP Basavaraju ◽  
N Devaraj

Chlorine n.q.r, in 2,6-dichlorophenol has been investigated at temperatures from 77 K to room temperature. Two resonance lines due to chemically inequivalent sites have been observed throughout this temperature range. Torsional frequencies of the molecule have been calculated at temperatures from 77 to 300 K according to Bayer's theory and Brown's method. Also the temperature coefficients of the torsional frequencies have been calculated.


1999 ◽  
Vol 13 (29n31) ◽  
pp. 3758-3763 ◽  
Author(s):  
AUGUST YURGENS ◽  
DAG WINKLER ◽  
TORD CLAESON ◽  
SEONG-JU HWANG ◽  
JIN-HO CHOY

The c-axis tunneling properties of both pristine Bi2212 and its HgBr 2 intercalate have been measured in the temperature range 4.2-250 K. Lithographically patterned 7-10 unit-cell heigh mesa structures on the surfaces of these single crystals were investigated. Clear SIS-like tunneling curves for current applied in the c-axis direction have been observed. The dynamic conductance d I/ d V(V) shows both sharp peaks corresponding to a superconducting gap edge and a dip feature beyond the gap, followed by a wide maximum, which persists up to a room temperature. Shape of the temperature dependence of the c-axis resistance does not change after the intercalation suggesting that a coupling between CuO 2-bilayers has little effect on the pseudogap.


2011 ◽  
Vol 483 ◽  
pp. 174-179 ◽  
Author(s):  
Ting Liang ◽  
Jian Jun Tang ◽  
Qian Qian Zhang ◽  
Yong Wang ◽  
Jing Li ◽  
...  

In this paper, We use a novel principle to detect acceleration and report how I-V characteristics and piezoresistance coefficient of AlGaN/GaN HEFT-micro-accelerometer are affected by setting different temperatures. It is shown that saturation current of device would go down if the temperature goes up, which is about 0.028mA/°C, based on the research. However, the device can work well at the temperature range of -50°C to 50°C, which indicates that it can work safely in the larger temperature range.


1992 ◽  
Vol 47 (1-2) ◽  
pp. 177-181 ◽  
Author(s):  
Shi-Qi Dou ◽  
Alarich Weiss

AbstractThe two line 35Cl NQR spectrum of 4,5-dichloroimidazole was measured in the temperature range 77≦ T/K ≦ 389. The temperature dependence of the NQR frequencies conforms with the Bayer model and no phase transition is indicated in the curves v ( 35Cl)= f(T). Also the temperature coefficients of the 35Cl NQR frequencies are "normal". At 77 K the 35Cl NQR frequencies are 37.409 MHz and 36.172 MHz and at 389 K 35.758 MHz and 34.565 MHz. The compound crystallizes at room temperature with the tetragonal space group D44-P41212, Z = 8 molecules per unit cell; at 295 K : a = 684.2(5) pm, c = 2414.0(20) pm. The relations between the crystal structure and the NQR spectrum are discussed.


2021 ◽  
Author(s):  
S.V. Zimina

Setting up artificial neural networks using iterative algorithms is accompanied by fluctuations in weight coefficients. When an artificial neural network solves the problem of allocating a useful signal against the background of interference, fluctuations in the weight vector lead to a deterioration of the useful signal allocated by the network and, in particular, losses in the output signal-to-noise ratio. The goal of the research is to perform a statistical analysis of an artificial neural network, that includes analysis of losses in the output signal-to-noise ratio associated with fluctuations in the weight coefficients of an artificial neural network. We considered artificial neural networks that are configured using discrete gradient, fast recurrent algorithms with restrictions, and the Hebb algorithm. It is shown that fluctuations lead to losses in the output signal/noise ratio, the level of which depends on the type of algorithm under consideration and the speed of setting up an artificial neural network. Taking into account the fluctuations of the weight vector in the analysis of the output signal-to-noise ratio allows us to correlate the permissible level of loss in the output signal-to-noise ratio and the speed of network configuration corresponding to this level when working with an artificial neural network.


1996 ◽  
Vol 14 (6) ◽  
pp. 659-664 ◽  
Author(s):  
A. V. Ivanov ◽  
Y. M. Gershenzon ◽  
F. Gratpanche ◽  
P. Devolder ◽  
J.-P. Sawerysyn

Abstract. The uptake coefficients (Γ) for OH radicals on some dry salts of tropospheric interest (NaCl and NH4NO3) have been investigated as a function of temperature using the flow tube technique combined with an EPR spectrometer as a detection method. The temperature dependence of Γ-values measured over the temperature range 245–340 K can be expressed in Arrhenius form: ΓOHNaCl=(1.2±0.7)×10–5exp[(1750±200)/T] and ΓOHNH4NO3=(1.4±0.5)×10–4exp[(1000±100)/T]. These Arrhenius expressions lead to very similar Γ-values (~4×10–3) for both salts studied at 300 K. It is shown that the heterogeneous OH sinks on solids aerosol play a very minor role in tropospheric chemistry in comparison with the homogeneous sinks.


Sign in / Sign up

Export Citation Format

Share Document