scholarly journals An adolescent with Behçet’s aortitis mimicking infective endocarditis: a case report

Author(s):  
Kaoru Hattori ◽  
Mimiko Tabata ◽  
Tohru Nojiri ◽  
Atsushi Kurata

Abstract Background Aortic valve involvement is rare in patients with Behçet’ s disease (BD); however, recurrent prosthetic valve detachment after valve surgery has frequently been reported. We report a rare case of Behçet’s aortitis involving the aortic valve, mimicking active infective endocarditis (IE) with perivalvular abscess. Case summary A 16-year-old boy, with an unknown case of BD, presented with pyrexia of unknown origin, severe aortic valve regurgitation, vegetation, and perivalvular abscess in the aortic valve. All cultures tested negative for microorganisms. As we suspected IE, aortic valve replacement was performed. After the initial surgery, recurrent prosthetic valve detachment and pseudoaneurysm formation occurred, which resulted in the diagnosis of BD. The patient underwent a modified Bentall procedure (MBP), in which the valve conduit was proximally sutured to the left ventricular outflow tract instead of the aortic annulus. Immunosuppressive therapy was initiated on the 10th postoperative day. His condition became stable, and additional surgery was not required. Discussion The echocardiographic findings of Behçet’s aortitis involving the aortic valve resemble those of aortic valve IE. MBP, combined with effective immunosuppressive therapy, may be useful in preventing prosthetic valve detachment.

2021 ◽  
Vol 5 (2) ◽  
Author(s):  
Nicholas Sunderland ◽  
Ahmed El-Medany ◽  
Justin Temporal ◽  
Laura Pannell ◽  
Gemina Doolub ◽  
...  

Abstract Background  The Gerbode defect is a rare abnormal communication between the left ventricle (LV) and right atrium (RA). The lesion is either congenital or acquired. Acquired defects are largely iatrogenic or infective in origin. We present two cases of acquired Gerbode defects with similar clinical presentations but very different outcomes. Case summaries Patient 1 A 64-year-old male presented with features of decompensated cardiac failure and a low-grade temperature. Dehiscence of a recently implanted bioprosthetic aortic valve and high-velocity LV to RA jet (Gerbode defect) was found on echocardiography. Blood cultures grew Staphylococcus warneri and the diagnosis of infective endocarditis was established. The patient was treated with intravenous antibiotics and the aortic valve and Gerbode defect were successfully surgically repaired. Patient 2 An 81-year-old male presented after being found on the floor at home. On admission, he was clinically septic with evidence of decompensated heart failure. No clear infective focus was initially found. Transthoracic echocardiography revealed severe left ventricular impairment, with a normal bioprosthetic aortic valve. He was treated with intravenous antibiotics, but later deteriorated with evidence of embolic phenomena. Repeat echocardiography revealed a complex infective aortic root lesion with bioprosthetic valve dehiscence and flow demonstrated from the LV to RA. Unfortunately, the patient succumbed to the infection and cardiac complications. Discussion  The Gerbode defect is a rare but important complication of infective endocarditis and valve surgery. Care needs to be taken to assess for Gerbode defect shunts on echocardiogram, especially in the context of previous cardiac surgery.


scholarly journals P1088Match and mismatch between opening area and resistance in mild and moderate rheumatic mitral stenosisP1089When should cardiovascular magnetic resonance imaging be considered in patients with chronic aortic or mitral regurgitation?P1090Echocardiographic characteristics of aortic valve fenestration with aortic regurgitation for aortic valve repairP1091Aortic regurgitation assessment by 3D transesophageal echocardiography vena contracta area: usefulness and comparison with 2D methods.P1092Characterising cardiomyopathy in mitral regurgitation due to barlow disease: role of CMRP1093Compensatory peripheral increase in artero-venous o2 difference to severe functional mitral regurgitation in heart failureP1094Prognostic impact of concomitant atrioventricular valve regurgitation in patients undergoing transcatheter aortic valve implantationP1095Morphological characterization of vegetations by real-time three-dimensional transesophageal echocardiography in infective endocarditis: prognostic impactP1096Relation between causative pathogen and echocardiographic findings in patients with infective endocarditis: is there an association and is it clinically relevant?P1097Aortic and mitral valve infective endocarditis: different clinical and echocardiographic features and peculiar complication ratesP1098Vegetation size relevance and impact on prognosis in patients with infective endocarditisP1099Causes of death on the valvular heart disease surveillance list- a 5 year auditP1100Left ventricular non-compaction and idiopathic dilated cardiomyopathy: the significant diagnostic value of longitudinal strainP1101The role of echocardiography in the management of diuretics withdrawal in patients with chronic heart failure and severely reduced ejection fraction: a prospective cohort studyP1102Outcomes in paediatric new onset left ventricle dysfunction and dilatation: differences between post-myocarditis and DCMP1103De novo mitral regurgitation as a cause of heart failure exacerbation in hypertrophic cardiomyopathyP1104Correlation of conventional and new echocardiograhic parameters with sudden cardiac death risk score in patients with hypertrophic cardiomyopathyP1105Inverse correlation between myocardial fibrosis and left ventricular function in rheumatic mitral stenosis: a preliminary study with cardiac magnetic resonanceP1106Left ventricular diastolic dysfunction and cardiac sympathetic derangement in patients with Anderson-Fabry disease: a 2D speckle tracking echocardiography and cardiac 123I-MIBG studyP1107Left ventricular hypertrophy and mild cognitive impairment as markers for target organ damage in hypertensive patients with multiple risk factorsP1108Subclinical left ventricular dysfunction in asymptomatic type 1 diabetic childrenP1109Minimal differences shown by echocardiography and NT-proBNP level distinguishing cardiotoxic effect related to breast cancer therapy in patients with or without HER2 expression.P1110Speed of recovery of left ventricular function is not related to the prognosis of takotsubo cardiomyopathy - a portuguese multicenter studyP1111Myocardial dysfunction in Takotsubo cardiomyopathy - more than meets the eye?P1112Obstructive sleep apnea and echocardiographic parameters

2016 ◽  
Vol 17 (suppl 2) ◽  
pp. ii227-ii234
Author(s):  
I. El-Dosouky ◽  
CL. Polte ◽  
T. Okubo ◽  
A. Gonzalez Gomez ◽  
B. Liu ◽  
...  

Author(s):  
Takashi Murashita ◽  
David L. Joyce ◽  
Alberto Pochettino ◽  
John M. Stulak ◽  
Lyle D. Joyce

Redo aortic valve replacement (AVR) performed simultaneously with left ventricular assist device (LVAD) implantation carries potential for increased mortality rates. Although transcatheter AVR has been used for patients with previous LVAD placement, no literature reports concomitant valve-in-valve transcatheter AVR and LVAD implantation. Our patient had severe aortic prosthetic valve deterioration and advanced heart failure. Given the risks associated with reoperative aortic valve surgery, we chose transcatheter AVR at the time of LVAD implantation. Transthoracic echocardiography results showed severe aortic prosthetic valve deterioration with moderate aortic regurgitation as well as severe left ventricular dysfunction (ejection fraction, 11%). After redosternotomy, we performed transcatheter AVR via the ascending aorta and subsequent LVAD implantation. The postoperative course was uneventful. Generally, patients with structural deterioration of a bioprosthetic valve who report for LVAD therapy present considerable challenges to the surgeon. Concomitant transcatheter AVR offers a less-invasive alternative to surgical AVR that minimizes ischemic injury to myocardium.


2009 ◽  
Vol 38 (6) ◽  
pp. 394-397
Author(s):  
Tomoki Choh ◽  
Shinichi Suzuki ◽  
Tomoyuki Minami ◽  
Hideyuki Iwaki ◽  
Yukihisa Isomatsu ◽  
...  

2021 ◽  
Vol 2021 (9) ◽  
Author(s):  
Toshio Doi ◽  
Kanetsugu Nagao ◽  
Hayato Obi ◽  
Akihiko Higashida ◽  
Masaya Aoki ◽  
...  

Abstract Annular abscess is a serious complication of infective endocarditis, which often requires complex surgery and has a very high post-operative mortality rate. The Konno procedure involves valve annuloplasty for a narrow aortic annulus or left ventricular outflow tract stenosis in children; it is also performed for various cardiac conditions in adults. Here, we report a case of the Konno procedure performed in a patient with aortic valve infective endocarditis, with an annular abscess extending into the interventricular septum (IVS). A 58-year-old man who presented to our hospital with fever was diagnosed with aortic valve infective endocarditis caused by Streptococcus saccharolyticus. On echocardiography, an annular abscess in the direction of the IVS was detected, and surgery was planned. The Konno procedure was performed to secure an adequate surgical field and to debride and reconstruct the cavity created by the interventricular septal abscess. The patient was discharged uneventfully 29 days after surgery.


2020 ◽  
Vol 21 (Supplement_1) ◽  
Author(s):  
A Tavernese ◽  
F Caldara ◽  
S Muscoli ◽  
M Stelitano ◽  
G Uccello ◽  
...  

Abstract INTRODUCTION Lactobacillus species are rare human pathogens but have been implicated in a variety of infections, including bacteremia and endocarditis, with Lactobacillus casei and Lactobacillus rhamnosus among the most frequently isolated species. Endocarditis due to Lactobacillus represents <0.5% of all cases of endocarditis and are associated with structural heart diseases, recent surgery, extended antibiotic and probiotic use and immuno-deficiency. We report a case of Lactobacillus plantarumendocarditis in a patient with biological aortic prosthetic valve. CASE REPORT Our patient is a 48 year-old male with a past medical history of surgical aortic replacement with a biological prosthetic valve in 2013. He reports the onset of symptoms 4 months before with worsening asthenia. The patient presented to a cardiologist after 3 months from symptoms beginning. A transesophageal echocardiogram (TEE) described marked fibro-plastic thickening of the cusps with two elongated vegetations (12 mm and 7 mm) causing a moderate-to-severe aortic steno-regurgitation. A few days later he came to our emergency department. On admission, the patient was afebrile, eupnoeic on room air. The cardiac examination revealed a regular rate and rhythm with a grade 4 of 6 holosystolic murmur loudest at the aortic and pulmonary focus. Three sets of blood cultures were drawn on admission. Hence, he was transferred to the Infectious Diseases Department where he started antibiotic therapy with Ceftriaxone and Gentamicin. A 18F-FDG PET-CT total body showed tracer accumulation close to the prosthetic aortic valve. Few days later Lactobacillus Plantarum was isolated from blood cultures and, according to the antibiogram results, therapy was adjusted using G Penicillin, Vancomicyn and Gentamicin. The TEE, performed during the hospitalization, showed one mobile vegetation, reduced in size (5 mm), adherent to the anterior aortic cusp, which prolapsed in the left ventricular outflow tract and commissural fusion, causing severe steno-regurgitation (Gmax 84 mmHg, Gmed 54 mmHg). During hospitalization the serial blood cultures resulted negative. Serial TEEs were also performed (3rdand 6thweek), showing a gradual reduction of the cusps thickening and disappearance of commissural fusion (Figure). In the last TEE no vegetations were described, and the transaortic mean gradient was reduced (Gmed 38 mmHg), persisting severe regurgitation. Hence the patient was discharged with oral antibiotic therapy (amoxicillin and clavulanic acid) and indication to redo aortic valve surgery. Written informed consent was obtained. CONCLUSIONS L. plantarum is a rare form of endocarditis. In our patient it caused fibro-plastic thickening of the bioprosthesis cusps and commissural fusion, determining severe steno-regurgitation. It also responded to targeted antibiotic therapy with improvement in cusp mobility but persistence of severe regurgitation. Abstract 95 Figure


Sign in / Sign up

Export Citation Format

Share Document