Predicting Risk of Surgery in Patients With Small Bowel Crohn’s Disease Strictures Using Computed Tomography and Magnetic Resonance Enterography

Author(s):  
Akitoshi Inoue ◽  
David J Bartlett ◽  
Narges Shahraki ◽  
Shannon P Sheedy ◽  
Jay P Heiken ◽  
...  

Abstract Background We aimed to determine if patient symptoms and computed tomography enterography (CTE) and magnetic resonance enterography (MRE) imaging findings can be used to predict near-term risk of surgery in patients with small bowel Crohn’s disease (CD). Methods CD patients with small bowel strictures undergoing serial CTE or MRE were retrospectively identified. Strictures were defined by luminal narrowing, bowel wall thickening, and unequivocal proximal small bowel dilation. Harvey-Bradshaw index (HBI) was recorded. Stricture observations and measurements were performed on baseline CTE or MRE and compared to with prior and subsequent scans. Patients were divided into those who underwent surgery within 2 years and those who did not. LASSO (least absolute shrinkage and selection operator) regression models were trained and validated using 5-fold cross-validation. Results Eighty-five patients (43.7 ± 15.3 years of age at baseline scan, majority male [57.6%]) had 137 small bowel strictures. Surgery was performed in 26 patients within 2 years from baseline CTE or MRE. In univariate analysis of patients with prior exams, development of stricture on the baseline exam was associated with near-term surgery (P = .006). A mathematical model using baseline features predicting surgery within 2 years included an HBI of 5 to 7 (odds ratio [OR], 1.7 × 105; P = .057), an HBI of 8 to 16 (OR, 3.1 × 105; P = .054), anastomotic stricture (OR, 0.002; P = .091), bowel wall thickness (OR, 4.7; P = .064), penetrating behavior (OR, 3.1 × 103; P = .096), and newly developed stricture (OR: 7.2 × 107; P = .062). This model demonstrated sensitivity of 67% and specificity of 73% (area under the curve, 0.62). Conclusions CTE or MRE imaging findings in combination with HBI can potentially predict which patients will require surgery within 2 years.

2020 ◽  
Vol 14 (4) ◽  
pp. 455-464
Author(s):  
Avinash K Nehra ◽  
Shannon P Sheedy ◽  
Michael L Wells ◽  
Wendaline M VanBuren ◽  
Stephanie L Hansel ◽  
...  

Abstract Background and Aims Our goal was to determine the importance of ileal inflammation at computed tomography or magnetic resonance enterography in Crohn’s disease patients with normal ileoscopy. Methods Patients with negative ileoscopy and biopsy within 30 days of CT or MR enterography showing ileal inflammation were included. The severity [0–3 scale] and length of inflammation within the distal 20 cm of the terminal ileum were assessed on enterography. Subsequent medical records were reviewed for ensuing surgery, ulceration at ileoscopy, histological inflammation, or new or worsening ileal inflammation or stricture on enterography. Imaging findings were classified as: Confirmed Progression [subsequent surgery or radiological worsening, new ulcers at ileoscopy or positive histology]; Radiologic Response [decreased inflammation with medical therapy]; or Unlikely/Unconfirmed Inflammation. Results Of 1471 patients undergoing enterography and ileoscopy, 112 [8%] had imaging findings of inflammation with negative ileoscopy, and 88 [6%] had negative ileoscopy and ileal biopsy. Half [50%; 44/88] with negative biopsy had moderate/severe inflammation at enterography, with 45%, 32% and 11% having proximal small bowel inflammation, stricture or fistulas, respectively. Two-thirds with negative biopsy [67%; 59/88] had Confirmed Progression, with 68%, 70% and 61% having subsequent surgical resection, radiological worsening or ulcers at subsequent ileoscopy, respectively. Mean length and severity of ileal inflammation in these patients was 10 cm and 1.6. Thirteen [15%] patients had Radiologic Response, and 16 [18%] had Unlikely/Unconfirmed Inflammation. Conclusion Crohn’s disease patients with unequivocal imaging findings of ileal inflammation at enterography despite negative ileoscopy and biopsy are likely to have active inflammatory Crohn’s disease. Disease detected by imaging may worsen over time or respond to medical therapy.


2012 ◽  
Vol 142 (5) ◽  
pp. S-169
Author(s):  
Danny Cheriyan ◽  
Eoin Slattery ◽  
Shaunagh McDermott ◽  
Aoife Kilcoyne ◽  
Denise Keegan ◽  
...  

2020 ◽  
Vol 7 (1) ◽  
pp. e000365 ◽  
Author(s):  
David Henry Bruining ◽  
Salvatore Oliva ◽  
Mark R Fleisher ◽  
Monika Fischer ◽  
Joel G Fletcher

IntroductionCrohn’s disease diagnosis and monitoring remains a great clinical challenge and often requires multiple testing modalities. Assessing Crohn’s disease activity in the entire gastrointestinal (GI) tract using a panenteric capsule endoscopy (CE) system could be used as an alternative to colonoscopy and cross-sectional imaging. This study assessed the accuracy and safety of panenteric CE in Crohn’s disease as compared with ileocolonoscopy (IC) and/or magnetic resonance enterography (MRE).MethodsA prospective, multicentre study was performed in subjects with established Crohn’s disease. Individuals with proven small bowel patency underwent a standardised bowel preparation, followed by CE ingestion and IC either the same or following day. MRE, IC, and CE interpretations were performed by blinded central readers using validated scoring systems. The primary endpoint was the overall sensitivity of CE vs MRE and/or IC in Crohn’s disease subjects.ResultsStudy enrolment included 158 subjects from 21 sites in the USA, Austria, and Israel. Of those, 99 were included in the analysis. Imaging modality scores indicated none to mild inflammation in the proximal small bowel and colon, but discrepant levels of inflammation in the terminal ileum. Overall sensitivity for active enteric inflammation (CE vs MRE and/or IC) was 94% vs 100% (p=0.125) and specificity was 74% vs 22% (p=0.001). Sensitivity of CE was superior to MRE for enteric inflammation in the proximal small bowel (97% vs 71%, p=0.021), and similar to MRE and/or IC in the terminal ileum and colon (p=0.500–0.625). There were seven serious adverse advents of which three were related to the CE device.ConclusionPanenteric CE is a reliable tool for assessing Crohn’s disease mucosal activity and extent compared with more invasive methods. This study demonstrates high performance of the panenteric CE as compared to MRE and/or IC without the need for multiple tests in non-stricturing Crohn’s disease.Trial registration numberClinicalTrials.gov NCT03241368


Sign in / Sign up

Export Citation Format

Share Document