scholarly journals Recent advances and novel approaches in laboratory-based diagnostic mycology

2019 ◽  
Vol 57 (Supplement_3) ◽  
pp. S259-S266 ◽  
Author(s):  
P Lewis White

Abstract The field of diagnostic mycology represents much more than culture and microscopy and is rapidly embracing novel techniques and strategies to help overcome the limitations of conventional approaches. Commercial molecular assays increase the applicability of PCR testing and may identify markers of antifungal resistance, which are of great clinical concern. Lateral flow assays simplify testing and turn-around time, with potential for point of care testing, while proximity ligation assays embrace the sensitivity of molecular testing with the specificity of antibody detection. The first evidence of patient risk stratification is being described and together with the era of next generation sequencing represents an exciting time in mycology.

2020 ◽  
Vol 58 (6) ◽  
Author(s):  
Thomas Z. Thompson ◽  
Allison R. McMullen

ABSTRACT Each year, there are an estimated 11 million visits to ambulatory care centers for pharyngitis in children between the ages of 3 and 18 years. While there are many causes of pediatric pharyngitis, group A streptococcal pharyngitis represents 15 to 30% of infections and is the only cause for which treatment is recommended. Unfortunately, clinical suspicion is insufficient for the accurate diagnosis of group A streptococcal pharyngitis, and laboratory testing for confirmation of Streptococcus pyogenes infection is required to prevent complications of infection. Traditionally, throat swabs are inoculated onto agar plates for isolation of the large-zone beta-hemolytic streptococcus. However, traditional culture methods present a potential delay in treatment due to turnaround times of 18 to 48 h. In order to improve turnaround times and enhance antimicrobial stewardship, multiple point-of-care assays have been developed. This review describes current point-of-care testing for group A streptococcal pharyngitis, including rapid antigen detection tests and more recent molecular methods. Additional attention is given to the diagnostic considerations when choosing a method for group A streptococcal point-of-care testing, implementation of molecular group A streptococcal testing, and the institutional cost of immunoassays compared to those of newer molecular methods.


2020 ◽  
Author(s):  
Susanna K. Elledge ◽  
Xin X. Zhou ◽  
James R. Byrnes ◽  
Alexander J. Martinko ◽  
Irene Lui ◽  
...  

Current serology tests for SARS-CoV-2 antibodies mainly take the form of enzyme-linked immunosorbent assays or lateral flow assays, with the former being laborious and the latter being expensive and often lacking sufficient sensitivity and scalability. Here we present the development and validation of a rapid, low-cost solution-based assay to detect antibodies in serum, plasma, whole blood, and saliva, using rationally designed split luciferase antibody biosensors (spLUC). This new assay, which generates quantitative results in as short as 5 minutes, substantially reduces the complexity and improves the scalability of COVID-19 antibody tests for point-of-care and broad population testing.


Author(s):  
Steven E Conklin ◽  
Kathryn Martin ◽  
Yukari C Manabe ◽  
Haley A Schmidt ◽  
Morgan Keruly ◽  
...  

Background. Rapid point-of-care tests (POCTs) for SARS-CoV-2-specific antibodies vary in performance. A critical need exists to perform head-to-head comparison of these assays. Methods. Performance of fifteen different lateral flow POCTs for the detection of SARS-CoV-2-specific antibodies was performed on a well characterized set of 100 samples. Of these, 40 samples from known SARS-CoV-2-infected, convalescent individuals (average of 45 days post symptom onset) were used to assess sensitivity. Sixty samples from the pre-pandemic era (negative control), that were known to have been infected with other respiratory viruses (rhinoviruses A, B, C and/or coronavirus 229E, HKU1, NL63 OC43) were used to assess specificity. The timing of seroconversion was assessed on five POCTs on a panel of 272 longitudinal samples from 47 patients of known time since symptom onset. Results. For the assays that were evaluated, the sensitivity and specificity for any reactive band ranged from 55%-97% and 78%-100%, respectively. When assessing the performance of the IgM and the IgG bands alone, sensitivity and specificity ranged from 0%-88% and 80%-100% for IgM and 25%-95% and 90%-100% for IgG. Longitudinal testing revealed that median time post symptom onset to a positive result was 7 days (IQR 5.4, 9.8) for IgM and 8.2 days (IQR 6.3 to 11.3). Conclusion. The testing performance varied widely among POCTs with most variation related to the sensitivity of the assays. The IgM band was most likely to misclassify pre-pandemic samples. The appearance of IgM and IgG bands occurred almost simultaneously.


Author(s):  
Steven E. Conklin ◽  
Kathryn Martin ◽  
Yukari C Manabe ◽  
Haley A Schmidt ◽  
Jernelle Miller ◽  
...  

Background. Rapid point-of-care tests (POCTs) for SARS-CoV-2-specific antibodies vary in performance. A critical need exists to perform head-to-head comparison of these assays. Methods. Performance of fifteen different lateral flow POCTs for the detection of SARS-CoV-2-specific antibodies was performed on a well characterized set of 100 samples. Of these, 40 samples from known SARS-CoV-2-infected, convalescent individuals (average of 45 days post symptom onset) were used to assess sensitivity. Sixty samples from the pre-pandemic era (negative control), that were known to have been infected with other respiratory viruses (rhinoviruses A, B, C and/or coronavirus 229E, HKU1, NL63 OC43) were used to assess specificity. The timing of seroconversion was assessed on five LFAs on a panel of 272 longitudinal samples from 47 patients of known time since symptom onset. Results. For the assays that were evaluated, the sensitivity and specificity for any reactive band ranged from 55%-97% and 78%-100%, respectively. When assessing the performance of the IgM and the IgG bands alone, sensitivity and specificity ranged from 0%-88% and 80%-100% for IgM and 25%-95% and 90%-100% for IgG. Longitudinal testing revealed that median time post symptom onset to a positive result was 7 days (IQR 5.4, 9.8) for IgM and 8.2 days (IQR 6.3 to 11.3) for IgG. Conclusion. The testing performance varied widely among LFAs with most variation related to the sensitivity of the assays. The IgM band was most likely to misclassify pre-pandemic samples. The appearance of IgM and IgG bands occurred almost simultaneously.


2020 ◽  
Author(s):  
K McAulay ◽  
EJ Kaleta ◽  
TE Grys

AbstractSARS-CoV-2 viremia has been demonstrated in some patients using molecular assays. Here we demonstrate detection of SARS-CoV-2 antigen in a cohort of hospitalized patients using a rapid diagnostic test from Anhui Deepblue Medical Technology Co., Ltd. We detected antigen in serum from 11 of 13 patients at time points ranging from three to eighteen days from symptom onset and observed that the disappearance of an antigen signal was associated with seroconversion. These results demonstrate proof of principle use of a rapid antigen test with serum samples in a format compatible with point of care testing.


2021 ◽  
Author(s):  
Sanjay Jain ◽  
Jonas Oddur Jonasson ◽  
Jean Pauphilet ◽  
Barnaby Flower ◽  
Maya Moshe ◽  
...  

Background: Quick, cheap and accurate point-of-care testing is urgently needed to enable frequent, large-scale testing to contain COVID-19. Lateral flow tests for antigen and antibody detection are an obvious candidate for use in community-wide testing, because they are quick and cheap relative to lab-processed tests. However, their low accuracy has limited their adoption. We develop a new methodology to increase the diagnostic accuracy of a combination of cheap, quick and inaccurate index tests with correlated or discordant outcomes, and illustrate its performance on commercially available lateral flow immunoassays (LFIAs) for Sars-CoV-2 antibody detection. Methods and Findings: We analyze laboratory test outcomes of 300 serum samples from health care workers detected with PCR-confirmed SARS-Cov-2 infection at least 21 days prior to sample collection, and 500 pre-pandemic serum samples, from a national seroprevalence survey, tested using eight LFIAs (Abbott, Biosure/Mologic, Orientgene-Menarini, Fortress, Biopanda I, Biopanda II, SureScreen and Wondfo) and Hybrid DABA as reference test. For each of 14 two-test combinations (e.g., Abbott, Fortress) and 16 three-test combinations (e.g., Abbott, Fortress, Biosure/Mologic) used on at least 100 positive and 100 negative samples, we classify an outcome sequence -- e.g., (+,-) for (Abbott, Fortress) -- as positive if its combination positive predictive value (CPPV) exceeds a given threshold, set between 0 and 1. Our main outcome measures are the sensitivity and specificity of different classification rules for classifying the outcomes of a combination test. We define testing possibility frontiers which represent sensitivity and false positive rates for different thresholds. The envelope of frontiers further enables test selection. The eight index tests individually meet neither the UK Medicines and Healthcare Products Regulatory Agency's 98% sensitivity and 98% specificity criterion, nor the US Center for Disease Control's 99.5% specificity criterion. Among these eight tests, the highest single-test LFIA specificity is 99.4% (with a sensitivity of 65.2%) and the highest single-test LFIA sensitivity is 93.4% (with a specificity of 97.4%). Using our methodology, a two-test combination meets the UK Medicines and Healthcare Products Regulatory Agency's criterion, achieving sensitivity of 98.4% and specificity of 98.0%. While two-test combinations meeting the US Center for Disease Control's 99.5% specificity criterion have sensitivity below 83.6%, a three-test combination delivers a specificity of 99.6% and a sensitivity of 95.8%. Conclusions: Current CDC guidelines suggest combining tests, noting that 'performance of orthogonal testing algorithms has not been systematically evaluated' and highlighting discordant outcomes. Our methodology combines available LFIAs to meet desired accuracy criteria, by identifying testing possibility frontiers which encompass benchmarks, enabling cost savings. Our methodology applies equally to antigen testing and can greatly expand testing capacity through combining less accurate tests, especially for use cases needing quick, accurate tests, e.g., entry to public spaces such as airports, nursing homes or hospitals.


2019 ◽  
Vol 116 ◽  
pp. 13-30 ◽  
Author(s):  
Tohid Mahmoudi ◽  
Miguel de la Guardia ◽  
Behnaz Shirdel ◽  
Ahad Mokhtarzadeh ◽  
Behzad Baradaran

2018 ◽  
Vol 58 (2) ◽  
pp. 442-446 ◽  
Author(s):  
Vi Tran ◽  
Bernd Walkenfort ◽  
Matthias König ◽  
Mohammad Salehi ◽  
Sebastian Schlücker