CORR Insights®: What Are the Tradeoffs in Outcomes after Casting Versus Surgery for Closed Extraarticular Distal Radius Fractures in Older Patients? A Statistical Learning Model

2021 ◽  
Vol Publish Ahead of Print ◽  
Author(s):  
Julia Blackburn
2008 ◽  
Vol 467 (6) ◽  
pp. 1612-1620 ◽  
Author(s):  
Andrew J. Synn ◽  
Eric C. Makhni ◽  
Melvin C. Makhni ◽  
Tamara D. Rozental ◽  
Charles S. Day

2015 ◽  
Vol 04 (S 01) ◽  
Author(s):  
Masao Nishiwaki ◽  
Mark Welsh ◽  
Louis Ferreira ◽  
James Johnson ◽  
Graham King ◽  
...  

2011 ◽  
Vol 93 (1) ◽  
pp. 57-60 ◽  
Author(s):  
DC Perry ◽  
DMG Machin ◽  
JA Casaletto ◽  
DJ Brown

INTRODUCTION Rupture of extensor pollicis longus (EPL) tendon is a recognised complication following volar plate fixation of distal radius fractures, usually from attrition caused by prominent screws. We sought to identify the screw holes in some of the most commonly used plates which may precipitate tendon injury. SUBJECTS AND METHODS Three fixed-angle volar locking plates were sequentially positioned into 18 cadaveric arms. A wire was passed through each of the holes in the plates using a locking guide and the dorsal relationships noted. RESULTS Each plate had specific ‘high-risk’ holes which directed the wire towards the EPL groove. The central screw holes appeared mostly implicated in EPL injury. CONCLUSIONS Awareness of ‘high-risk’ holes and appropriate minor alterations in surgical technique may consequently decrease the incidence of EPL irritation and rupture.