scholarly journals Comparison of the intermediate distance of a trifocal IOL with an extended depth-of-focus IOL: results of a prospective randomized trial

2020 ◽  
Vol 46 (2) ◽  
pp. 193-203 ◽  
Author(s):  
Valentijn S.C. Webers ◽  
Noel J.C. Bauer ◽  
Isabelle E.Y. Saelens ◽  
Onne J.M. Creten ◽  
Tos T.J.M. Berendschot ◽  
...  
2021 ◽  
Vol 37 (8) ◽  
pp. 532-537
Author(s):  
Javier Ruiz-Alcocer ◽  
Irene Martínez-Alberquilla ◽  
Laureano A. Rementería-Capelo ◽  
Pablo De Gracia ◽  
Amalia Lorente-Velázquez

2020 ◽  
Vol 36 (8) ◽  
pp. 528-535
Author(s):  
Ji Eun Song ◽  
Ramin Khoramnia ◽  
Hyeck-Soo Son ◽  
Michael C. Knorz ◽  
Chul Young Choi

2018 ◽  
Vol 2018 ◽  
pp. 1-8 ◽  
Author(s):  
Santiago Escandón-García ◽  
Filomena J. Ribeiro ◽  
Colm McAlinden ◽  
António Queirós ◽  
José M. González-Méijome

Purpose. To compare the through-focus visual performance in a clinical population of pseudophakic patients implanted with two new trifocal intraocular lenses (IOLs) and one extended depth of focus IOL. Methods. Prospective, nonrandomized, examiner-masked case series. Twenty-three patients received the FineVision® and seven patients received the PanOptix™ trifocal IOLs. Fifteen patients received the Symfony extended depth of focus IOL. Mean age of patients was 63 ± 8 years. Through-focus visual acuity was measured from –3.00 to +1.00 D vergences. Contrast sensitivity was measured with and without a source of glare. Light disturbances were evaluated with the Light Distortion Analyzer. Results. Though-focus evaluation showed that trifocal IOLs performed significantly better at near distance (33 and 40 cm), and extended depth of focus performed significantly better at intermediate distance (1.0 m). Contrast sensitivity function with glare and dysphotopsia was similar between the three IOLs and subjective response to questionnaire showed a significantly higher score (worse performance) for the extended depth of focus IOL compared to both trifocal IOLs in the bothersome subscale (p<0.05). Conclusions. Trifocal IOLs grant better performance at near distance while extended depth of focus IOL performs better at intermediate distance. Objective dysphotopsia measured with the Light Distortion Analyzer is not reduced in extended depth of focus IOL compared to trifocal IOLs.


Author(s):  
Richard N. McNeely ◽  
Salissou Moutari ◽  
Stephen Stewart ◽  
Jonathan E. Moore

Abstract Purpose To assess the 1-month and 12-month postoperative visual performance and subjective outcomes following combined implantation of an extended depth of focus (EDOF) intraocular lens (IOL) and a trifocal IOL. Methods The study enrolled consecutive patients undergoing refractive lens extraction or cataract surgery with combined implantation of an EDOF IOL (dominant eye) and trifocal IOL. Uncorrected (UDVA) and best-corrected (CDVA) distance visual acuities, uncorrected intermediate (UIVA) and near (UNVA) visual acuities, and subjective questionnaires were evaluated 1 month and 12 months postoperatively. Results The study enrolled 58 consecutive patients. Binocular UDVA, UIVA and UNVA were − 0.08 ± 0.07 logMAR, 0.15 ± 0.14 logMAR and 0.17 ± 0.11 logMAR at 1 month, compared to − 0.09 ± 0.06 logMAR (P = .323), 0.11 ± 0.10 logMAR (P = .030) and 0.13 ± 0.10 logMAR (P = 0.008) at 12 months. Satisfaction was high with 93.1% of patients fulfilled or more than fulfilled postoperatively, and 84.5% and 86.3% reported spectacle independence for near at the respective postoperative assessments. The mean daytime and nighttime quality of vision (QoV) scores were 9.12 ± 0.94 and 7.88 ± 1.74 at 1 month, compared to 9.24 ± 0.78 (P = .183) and 8.26 ± 1.38 (P = .043) at 12 months. Conclusions This IOL combination provides good unaided visual acuity at 1 and 12 months postoperatively, with high functional vision and postoperative satisfaction reported at 1 and 12 months. However, a significant improvement in overall nighttime QoV at the 12 months assessment was found.


2021 ◽  
Vol 2021 ◽  
pp. 1-9
Author(s):  
Ji Eun Song ◽  
So Young Han ◽  
Ramin Khoramnia ◽  
Tamer Tandogan ◽  
Gerd U. Auffarth ◽  
...  

Purpose. To evaluate monocular and binocular visual performance and patient-reported outcomes following combined implantation of a diffractive extended depth of focus (EDoF) IOL (Carl Zeiss AT LARA 829MP) and a diffractive trifocal IOL (Carl Zeiss AT LISA tri 839MP). Methods. This prospective study enrolled consecutive patients undergoing lens phacoemulsification of cataract and combined implantation of an EDoF IOL in the dominant eye and a trifocal IOL in the nondominant eye. Assessment included uncorrected visual acuity at near distances (UNVA), intermediate distances (UIVA), and far distances (UDVA), uncorrected defocus curve, contrast sensitivity (CS), reading speed, and patient satisfaction, evaluated six months after the surgery with the Visual Function Questionnaire (VFQ-25). Results. A total of 25 patients were enrolled. At six months postoperatively, outcomes of binocular UNVA, UIVA, and UDVA were superior to those of monocular outcomes. The binocular defocus curve showed significantly better results in comparison with the AT LISA tri IOL eyes at defocus levels of −1.0 D and −1.5 D ( P = 0.008 and P = 0.002 , respectively) and compared to the AT LARA IOL eyes at defocus levels of −3.0, −3.5 D, and −4.0 D ( P = 0.019 , P = 0.019 , and P = 0.035 , respectively). All of the patients were spectacle-free at far and intermediate distances, while 4% of patients needed spectacles at the near distance. Reading speed showed a rather high and gentle slope curve between 0.1 logMAR and 0.4 logMAR, and optical phenomena were improved after combined implantation of IOLs except halos. There were no significant differences in CS between the binocular and monocular results of each IOL. Conclusions. The combined implantation of an EDoF IOL and a trifocal IOL seems to be a good option for patients with demands for spectacle independence in their daily life, with minimal photic phenomena.


2022 ◽  
Author(s):  
Ricardo Y Abe ◽  
Maíra Gomes Barbosa da Silva ◽  
Thiago Nogueira Alves ◽  
Wilson Takashi Hida

Abstract Purpose: To evaluate reliability and global indices parameters from standard automated perimetry (SAP) in normal eyes undergoing phacoemulsification cataract surgery with implantation of trifocal or extended depth of focus intraocular lens (IOL).Methods: Prospective comparative study. Comparison of trifocal IOL AcrySof IQ PanOptix® and extended depth of focus intraocular lens (EDOF) Tecnis Symfony® IOL. Patients underwent SAP pre- and postoperatively. Reliability indices (false negative rate - FN, false positive rate – FP), global indices (foveal sensitivity threshold, visual field index - VFI, standard pattern deviation – PSD, mean deviation MD) and test duration were analyzed.Results: A total of 23 eyes from 13 patients were in the trifocal IOL group and a total of 22 eyes from 14 patients were in the EDOF group The following results were obtained by analyzing pre- and postoperative SAP of EDOF IOL: the rate of change of FN was 1.95/1.41% (p=0.61); FP 1.64/1.27 (p=0.60); MD -1.60/-1.08dB (p=0.15); foveal sensitivity was 34.5/33.9dB (p=0.41); VFI 98.5/98.4% (p>0.99); PSD 1.85/1.86 (p=0.07); and for test duration 305.81/298.36s (p=0.35); all respectively. Analysis of pre- and postoperative parameters of trifocal IOL was: the rates of change of FN 1.22/1.83% (p=0.29); FP 1.65/1.48% (p=0.95); MD -1.55/-1.37dB (p=0.19) ; foveal sensitivity 33.9/34.9dB (p=0.47) ; VFI 98.6/98.3% (p=0.62); PSD 1.58/2.05 (p=0.02); and test duration 297.17/298.57s (p=0.87); all respectively. Conclusion: We identified a change in the PSD parameters in the trifocal IOL group. No other significant changes were identified in SAP parameters after implantation of trifocal AcrySof IQ PanOptix® and EDOF Tecnis Symfony® IOL. Longitudinal evaluation showed no changes in SAP after Trifocal and EDOF IOL implantation in normal subjects.


2020 ◽  
Vol 36 (7) ◽  
pp. 435-441 ◽  
Author(s):  
Javier Ruiz-Alcocer ◽  
Amalia Lorente-Velázquez ◽  
José Luis Hernández-Verdejo ◽  
Pablo De Gracia ◽  
David Madrid-Costa

Sign in / Sign up

Export Citation Format

Share Document