Characterization and interpretation of the quantum efficiencies of multilayer semiconductor detectors using a new theory

1998 ◽  
Vol 5 (3) ◽  
pp. 877-879
Author(s):  
T. Cho ◽  
M. Hirata ◽  
J. Kohagura ◽  
Y. Sakamoto ◽  
T. Okamura ◽  
...  

On the basis of a new theory of semiconductor X-ray detector response, a new type of multilayer semiconductor detector was designed and developed for convenient energy analyses of intense incident X-ray flux in a cumulative-current mode. Another anticipated useful property of the developed detector is a drastic improvement in high-energy X-ray response ranging over several hundred eV. The formula for the quantum efficiency of multilayer semiconductor detectors and its physical interpretations are proposed and have been successfully verified by synchrotron radiation experiments at the Photon Factory. These detectors are useful for data analyses under strong radiation-field conditions, including fusion-plasma-emitting X-rays and energetic heavy-particle beams, without the use of high-bias applications.

2008 ◽  
Vol 16 (2) ◽  
pp. 6-9
Author(s):  
David O’Hara ◽  
Greg Brown ◽  
Eric Lochner

Although considerable advances have been made in Energy Dispersive Detectors for microanalysis, low energy analysis under 1000eV is still relatively poor due to detector response and inefficient production of low energy x-rays. X-ray optics fabrication methods by O’Hara and measurements by McCarthy et. al. indicated that it should be possible to fabricate x-ray optics that could be used to significantly increase the low energy x-ray flux seen by an EDS detector without increasing the beam current. Such an optic would be useful to increase low energy counts without moving the detector closer, which would simply increase the high energy counts and dead time.


2006 ◽  
Vol 524-525 ◽  
pp. 743-748 ◽  
Author(s):  
Alexander M. Korsunsky ◽  
Shu Yan Zhang ◽  
Daniele Dini ◽  
Willem J.J. Vorster ◽  
Jian Liu

Diffraction of penetrating radiation such as neutrons or high energy X-rays provides a powerful non-destructive method for the evaluation of residual stresses in engineering components. In particular, strain scanning using synchrotron energy-dispersive X-ray diffraction has been shown to offer a fast and highly spatially resolving measurement technique. Synchrotron beamlines provide best available instruments in terms of flux and low beam divergence, and hence spatial and measurement resolution and data collection rate. However, despite the rapidly growing number of facilities becoming available in Europe and across the world, access to synchrotron beamlines for routine industrial and research use remains regulated, comparatively slow and expensive. A laboratory high energy X-ray diffractometer for bulk residual strain evaluation (HEXameter) has been developed and built at Oxford University. It uses a twin-detector setup first proposed by one of the authors in the energy dispersive X-ray diffraction mode and allows simultaneous determination of macroscopic and microscopic strains in two mutually orthogonal directions that lie approximately within the plane normal to the incident beam. A careful procedure for detector response calibration is used in order to facilitate accurate determination of lattice parameters by pattern refinement. The results of HEXameter measurements are compared with synchrotron X-ray data for several samples e.g. made from a titanium alloy and a particulate composite with an aluminium alloy matrix. Experimental results are found to be consistent with synchrotron measurements and strain resolution close to 2×10-4 is routinely achieved by the new instrument.


2015 ◽  
Vol 11 (S320) ◽  
pp. 439-441
Author(s):  
Jaromir Barylak ◽  
Aleksandra Barylak ◽  
Tomasz Mrozek ◽  
Marek Steślicki ◽  
Piotr Podgórski ◽  
...  

AbstractSpectrometer/Telescope for Imaging X-rays (STIX) is a part of Solar Orbiter (SO) science payload. SO will be launched in October 2018, and after three years of cruise phase, it will reach orbit with perihelion distance of 0.3 a.u. STIX is a Fourier imager equipped with pairs of grids that comprise the flare hard X-ray tomograph. Similar imager types were already used in the past (eq. RHESSI, Yohkoh/HXT), but STIX will incorporate Moiré modulation and a new type of pixelized detectors with CdTe sensor. We developed a method of modeling these detectors' response matrix (DRM) using the Geant4 simulations of X-ray photons interactions with CdTe crystals. Taking into account known detector effects (Fano noise, hole tailing etc.) we modeled the resulting spectra with high accuracy. Comparison of Caliste-SO laboratory measurements of 241Am decay spectrum with our results shows a very good agreement. The modeling based on the Geant4 simulations significantly improves our understanding of detector response to X-ray photons. Developed methodology gives opportunity for detailed simulation of whole instrument response with complicated geometry and secondary radiation from cosmic ray particles taken into account. Moreover, we are developing the Geant4 simulations of aging effects which decrease detector's performance.


Author(s):  
A.J. Tousimis

An integral and of prime importance of any microtopography and microanalysis instrument system is its electron, x-ray and ion detector(s). The resolution and sensitivity of the electron microscope (TEM, SEM, STEM) and microanalyzers (SIMS and electron probe x-ray microanalyzers) are closely related to those of the sensing and recording devices incorporated with them.Table I lists characteristic sensitivities, minimum surface area and depth analyzed by various methods. Smaller ion, electron and x-ray beam diameters than those listed, are possible with currently available electromagnetic or electrostatic columns. Therefore, improvements in sensitivity and spatial/depth resolution of microanalysis will follow that of the detectors. In most of these methods, the sample surface is subjected to a stationary, line or raster scanning photon, electron or ion beam. The resultant radiation: photons (low energy) or high energy (x-rays), electrons and ions are detected and analyzed.


1998 ◽  
Vol 5 (3) ◽  
pp. 515-517 ◽  
Author(s):  
M. Frank ◽  
C. A. Mears ◽  
S. E. Labov ◽  
L. J. Hiller ◽  
J. B. le Grand ◽  
...  

Experimental results are presented obtained with a cryogenically cooled high-resolution X-ray spectrometer based on a 141 × 141 µm Nb-Al-Al2O3-Al-Nb superconducting tunnel junction (STJ) detector in an SR-XRF demonstration experiment. STJ detectors can operate at count rates approaching those of semiconductor detectors while still providing a significantly better energy resolution for soft X-rays. By measuring fluorescence X-rays from samples containing transition metals and low-Z elements, an FWHM energy resolution of 6–15 eV for X-rays in the energy range 180–1100 eV has been obtained. The results show that, in the near future, STJ detectors may prove very useful in XRF and microanalysis applications.


2013 ◽  
Vol 46 (5) ◽  
pp. 1508-1512 ◽  
Author(s):  
Byron Freelon ◽  
Kamlesh Suthar ◽  
Jan Ilavsky

Coupling small-angle X-ray scattering (SAXS) and ultra-small-angle X-ray scattering (USAXS) provides a powerful system of techniques for determining the structural organization of nanostructured materials that exhibit a wide range of characteristic length scales. A new facility that combines high-energy (HE) SAXS and USAXS has been developed at the Advanced Photon Source (APS). The application of X-rays across a range of energies, from 10 to 50 keV, offers opportunities to probe structural behavior at the nano- and microscale. An X-ray setup that can characterize both soft matter or hard matter and high-Zsamples in the solid or solution forms is described. Recent upgrades to the Sector 15ID beamline allow an extension of the X-ray energy range and improved beam intensity. The function and performance of the dedicated USAXS/HE-SAXS ChemMatCARS-APS facility is described.


2004 ◽  
Vol 37 (6) ◽  
pp. 901-910 ◽  
Author(s):  
C. Seitz ◽  
M. Weisser ◽  
M. Gomm ◽  
R. Hock ◽  
A. Magerl

A triple-axis diffractometer for high-energy X-ray diffraction is described. A 450 kV/4.5 kW stationary tungsten X-ray tube serves as the X-ray source. Normally, 220 reflections of thermally annealed Czochralski Si are employed for the monochromator and analyser. Their integrated reflectivity is about ten times higher than the ideal crystal value. With the same material as the sample, and working with the WKα line at 60 keV in symmetric Laue geometry for all axes, the full width at half-maximum (FWHM) values for the longitudinal and transversal resolution are 2.5 × 10−3and 1.1 × 10−4for ΔQ/Q, respectively, and the peak intensity for a non-dispersive setting is 3000 counts s−1. In particular, for a double-axis mode, an energy well above 100 keV from theBremsstrahlungspectrum can be used readily. High-energy X-rays are distinguished by a high penetration power and materials of several centimetre thickness can be analysed. The feasibility of performing experiments with massive sample environments is demonstrated.


2020 ◽  
Vol 499 (2) ◽  
pp. 3006-3018
Author(s):  
Bangzheng Sun ◽  
Marina Orio ◽  
Andrej Dobrotka ◽  
Gerardo Juan Manuel Luna ◽  
Sergey Shugarov ◽  
...  

ABSTRACT We present X-ray observations of novae V2491 Cyg and KT Eri about 9 yr post-outburst of the dwarf nova and post-nova candidate EY Cyg, and of a VY Scl variable. The first three objects were observed with XMM–Newton, KT Eri also with the Chandra ACIS-S camera, V794 Aql with the Chandra ACIS-S camera and High Energy Transmission Gratings. The two recent novae, similar in outburst amplitude and light curve, appear very different at quiescence. Assuming half of the gravitational energy is irradiated in X-rays, V2491 Cyg is accreting at $\dot{m}=1.4\times 10^{-9}{\!-\!}10^{-8}\,{\rm M}_\odot \,{\rm yr}^{-1}$, while for KT Eri, $\dot{m}\lt 2\times 10^{-10}{\rm M}_\odot \,{\rm yr}$. V2491 Cyg shows signatures of a magnetized WD, specifically of an intermediate polar. A periodicity of  39 min, detected in outburst, was still measured and is likely due to WD rotation. EY Cyg is accreting at $\dot{m}\sim 1.8\times 10^{-11}{\rm M}_\odot \,{\rm yr}^{-1}$, one magnitude lower than KT Eri, consistently with its U Gem outburst behaviour and its quiescent UV flux. The X-rays are modulated with the orbital period, despite the system’s low inclination, probably due to the X-ray flux of the secondary. A period of  81 min is also detected, suggesting that it may also be an intermediate polar. V794 Aql had low X-ray luminosity during an optically high state, about the same level as in a recent optically low state. Thus, we find no clear correlation between optical and X-ray luminosity: the accretion rate seems unstable and variable. The very hard X-ray spectrum indicates a massive WD.


2019 ◽  
Vol 9 (1) ◽  
Author(s):  
Kotaro Matsumoto ◽  
Hiroyuki Saitoh ◽  
Tan Le Hoang Doan ◽  
Ayumi Shiro ◽  
Keigo Nakai ◽  
...  

Abstract Synchrotron generated monochromatic X-rays can be precisely tuned to the K-shell energy of high Z materials resulting in the release of the Auger electrons. In this work, we have employed this mechanism to destruct tumor spheroids. We first loaded gadolinium onto the surface of mesoporous silica nanoparticles (MSNs) producing gadolinium-loaded MSN (Gd-MSN). When Gd-MSN was added to the tumor spheroids, we observed efficient uptake and uniform distribution of Gd-MSN. Gd-MSN also can be taken up into cancer cells and localize to a site just outside of the cell nucleus. Exposure of the Gd-MSN containing tumor spheroids to monochromatic X-ray beams resulted in almost complete destruction. Importantly, this effect was observed at an energy level of 50.25 keV, but not with 50.0 keV. These results suggest that it is possible to use precisely tuned monochromatic X-rays to destruct tumor mass loaded with high Z materials, while sparing other cells. Our experiments point to the importance of nanoparticles to facilitate loading of gadolinium to tumor spheroids and to localize at a site close to the nucleus. Because the nanoparticles can target to tumor, our study opens up the possibility of developing a new type of radiation therapy for cancer.


Sign in / Sign up

Export Citation Format

Share Document