Deep Heterogeneous Dilation of LSTM for Transient-phase Gesture Prediction through High-density Electromyography: Towards Application in Neurorobotics

Author(s):  
Tianyun Sun ◽  
Qin Hu ◽  
Jacqueline Libby ◽  
S. Farokh Atashzar
Keyword(s):  
2021 ◽  
Author(s):  
Tianyun Sun ◽  
Qin Hu ◽  
Jacqueline Libby ◽  
S. Farokh Atashzar

Deep networks have been recently proposed to estimate motor intention using conventional bipolar surface electromyography (sEMG) signals for myoelectric control of neurorobots. In this regard, deepnets are generally challenged by long training times (affecting the practicality and calibration), complex model architectures (affecting the predictability of the outcomes), a large number of trainable parameters (increasing the need for big data), and possibly overfitting. Capitalizing on our recent work on homogeneous temporal dilation in a Recurrent Neural Network (RNN) model, this paper proposes, for the first time, heterogeneous temporal dilation in an LSTM model and applies that to high-density surface electromyography (HD-sEMG), allowing for decoding dynamic temporal dependencies with tunable temporal foci. In this paper, a 128-channel HD-sEMG signal space is considered due to the potential for enhancing the spatiotemporal resolution of human-robot interfaces. Accordingly, this paper addresses a challenging motor intention decoding problem of neurorobots, namely, transient intention identification. The aforementioned problem only takes into account the dynamic and transient phase of gesture movements when the signals are not stabilized or plateaued, addressing which can significantly enhance the temporal resolution of human-robot interfaces. This would eventually enhance seamless real-time implementations. Additionally, this paper introduces the concept of dilation foci to modulate the modeling of temporal variation in transient phases. In this work a high number (i.e. 65) of gestures is included, which adds to the complexity and significance of the understudied problem. Our results show state-of-the-art performance for gesture prediction in terms of accuracy, training time, and model convergence.


Author(s):  
S. McKernan ◽  
C. B. Carter ◽  
D. Bour ◽  
J. R. Shealy

The growth of ternary III-V semiconductors by organo-metallic vapor phase epitaxy (OMVPE) is widely practiced. It has been generally assumed that the resulting structure is the same as that of the corresponding binary semiconductors, but with the two different cation or anion species randomly distributed on their appropriate sublattice sites. Recently several different ternary semiconductors including AlxGa1-xAs, Gaxln-1-xAs and Gaxln1-xP1-6 have been observed in ordered states. A common feature of these ordered compounds is that they contain a relatively high density of defects. This is evident in electron diffraction patterns from these materials where streaks, which are typically parallel to the growth direction, are associated with the extra reflections arising from the ordering. However, where the (Ga,ln)P epilayer is reasonably well ordered the streaking is extremely faint, and the intensity of the ordered spot at 1/2(111) is much greater than that at 1/2(111). In these cases it is possible to image relatively clearly many of the defects found in the ordered structure.


Author(s):  
L. Mulestagno ◽  
J.C. Holzer ◽  
P. Fraundorf

Due to the wealth of information, both analytical and structural that can be obtained from it TEM always has been a favorite tool for the analysis of process-induced defects in semiconductor wafers. The only major disadvantage has always been, that the volume under study in the TEM is relatively small, making it difficult to locate low density defects, and sample preparation is a somewhat lengthy procedure. This problem has been somewhat alleviated by the availability of efficient low angle milling.Using a PIPS® variable angle ion -mill, manufactured by Gatan, we have been consistently obtaining planar specimens with a high quality thin area in excess of 5 × 104 μm2 in about half an hour (milling time), which has made it possible to locate defects at lower densities, or, for defects of relatively high density, obtain information which is statistically more significant (table 1).


Author(s):  
Evelyn R. Ackerman ◽  
Gary D. Burnett

Advancements in state of the art high density Head/Disk retrieval systems has increased the demand for sophisticated failure analysis methods. From 1968 to 1974 the emphasis was on the number of tracks per inch. (TPI) ranging from 100 to 400 as summarized in Table 1. This emphasis shifted with the increase in densities to include the number of bits per inch (BPI). A bit is formed by magnetizing the Fe203 particles of the media in one direction and allowing magnetic heads to recognize specific data patterns. From 1977 to 1986 the tracks per inch increased from 470 to 1400 corresponding to an increase from 6300 to 10,800 bits per inch respectively. Due to the reduction in the bit and track sizes, build and operating environments of systems have become critical factors in media reliability.Using the Ferrofluid pattern developing technique, the scanning electron microscope can be a valuable diagnostic tool in the examination of failure sites on disks.


VASA ◽  
2014 ◽  
Vol 43 (3) ◽  
pp. 189-197 ◽  
Author(s):  
Yiqiang Zhan ◽  
Jinming Yu ◽  
Rongjing Ding ◽  
Yihong Sun ◽  
Dayi Hu

Background: The associations of triglyceride (TG) to high-density lipoprotein cholesterol ratio (HDL‑C) and total cholesterol (TC) to HDL‑C ratio and low ankle brachial index (ABI) were seldom investigated. Patients and methods: A population based cross-sectional survey was conducted and 2982 participants 60 years and over were recruited. TG, TC, HDL‑C, and low-density lipoprotein cholesterol (LDL-C) were assessed in all participants. Low ABI was defined as ABI ≤ 0.9 in either leg. Multiple logistic regression models were applied to study the association between TG/HDL‑C ratio, TC/HDL‑C ratio and low ABI. Results: The TG/HDL‑C ratios for those with ABI > 0.9 and ABI ≤ 0.9 were 1.28 ± 1.20 and 1.48 ± 1.13 (P < 0.0001), while the TC/HDL‑C ratios were 3.96 ± 1.09 and 4.32 ± 1.15 (P < 0.0001), respectively. After adjusting for age, gender, body mass index, obesity, current drinking, physical activity, hypertension, diabetes, lipid-lowering drugs, and cardiovascular disease history, the odds ratios (ORs) with 95 % confidence intervals (CIs) of low ABI for TG/HDL‑C ratio and TC/HDL‑C ratio were 1.10 (0.96, 1.26) and 1.34 (1.14, 1.59) in non-smokers. When TC was further adjusted, the ORs (95 % CIs) were 1.40 (0.79, 2.52) and 1.53 (1.21, 1.93) for TG/HDL‑C ratio and TC/HDL‑C ratio, respectively. Non-linear relationships were detected between TG/HDL‑C ratio and TC/HDL‑C ratio and low ABI in both smokers and non-smokers. Conclusions: TC/HDL‑C ratio was significantly associated with low ABI in non-smokers and the association was independent of TC, TG, HDL‑C, and LDL-C. TC/HDL‑C might be considered as a potential biomarker for early peripheral arterial disease screening.


Sign in / Sign up

Export Citation Format

Share Document