Minimizing Power Loss and Improving Voltage Stability in Distribution System Through Optimal Allocation of Distributed Generation Using Electrostatic Discharge Algorithm

Author(s):  
Mansur Khasanov ◽  
Salah Kamel ◽  
Hussein Abdel-Mawgoud
Energies ◽  
2019 ◽  
Vol 12 (3) ◽  
pp. 553 ◽  
Author(s):  
Arun Onlam ◽  
Daranpob Yodphet ◽  
Rongrit Chatthaworn ◽  
Chayada Surawanitkun ◽  
Apirat Siritaratiwat ◽  
...  

This paper proposes a novel adaptive optimization algorithm to solve the network reconfiguration and distributed generation (DG) placement problems with objective functions including power loss minimization and voltage stability index (VSI) improvement. The proposed technique called Adaptive Shuffled Frogs Leaping Algorithm (ASFLA) was performed for solving network reconfiguration and DG installation in IEEE 33- and 69-bus distribution systems with seven different scenarios. The performance of ASFLA was compared to that of other algorithms such as Fireworks Algorithm (FWA), Adaptive Cuckoo Search Algorithm (ACSA) and Shuffled Frogs Leaping Algorithm (SFLA). It was found that the power loss and VSI provided by ASFLA were better than those given by FWA, ACSA and SFLA in both 33- and 69-bus systems. The best solution of power loss reduction and VSI improvement of both 33- and 69-bus systems was achieved when the network reconfiguration with optimal sizing and the location DG were simultaneously implemented. From our analysis, it was indicated that the ASFLA could provide better solutions than other methods since the generating process, local and global searching of this algorithm were significantly improved from a conventional method. Hence, the ASFLA becomes another effective algorithm for solving network reconfiguration and DG placement problems in electrical distribution systems.


2021 ◽  
Vol 3 (1) ◽  
Author(s):  
Varaprasad Janamala

AbstractA new meta-heuristic Pathfinder Algorithm (PFA) is adopted in this paper for optimal allocation and simultaneous integration of a solar photovoltaic system among multi-laterals, called interline-photovoltaic (I-PV) system. At first, the performance of PFA is evaluated by solving the optimal allocation of distribution generation problem in IEEE 33- and 69-bus systems for loss minimization. The obtained results show that the performance of proposed PFA is superior to PSO, TLBO, CSA, and GOA and other approaches cited in literature. The comparison of different performance measures of 50 independent trail runs predominantly shows the effectiveness of PFA and its efficiency for global optima. Subsequently, PFA is implemented for determining the optimal I-PV configuration considering the resilience without compromising the various operational and radiality constraints. Different case studies are simulated and the impact of the I-PV system is analyzed in terms of voltage profile and voltage stability. The proposed optimal I-PV configuration resulted in loss reduction of 77.87% and 98.33% in IEEE 33- and 69-bus systems, respectively. Further, the reduced average voltage deviation index and increased voltage stability index result in an improved voltage profile and enhanced voltage stability margin in radial distribution systems and its suitability for practical applications.


2012 ◽  
Vol 433-440 ◽  
pp. 7190-7194 ◽  
Author(s):  
Nattachote Rugthaicharoencheep ◽  
Thong Lantharthong ◽  
Awiruth Ratreepruk ◽  
Jenwit Ratchatha

This paper presents the optimal and sizing of distributed generation (DG) placement in a radial distribution system for loss reduction. The main emphasis of this paper is to identify proper locations for installing DGs in a distribution system to reduce active power loss and improve bus voltages. Nevertheless, proper placement and sizing of DG units are not straightforward to be identified as a number of their positions and capacities need to be determined. It is therefore proposed in this paper to solve a DG placement problem based on a Tabu search algorithm. The objective function of the problem is to minimize the system loss subject to power flow constraints, bus voltage limits, pre specified number of DGs, and their allowable total installed capacity, and only one distributed generator for one installation position. The effectiveness of the methodology is demonstrated by a practical sized distribution system consisting of 69 bus and 48 load points. The results show that the optimal DG placement and sizing can be identified to give the minimum power loss while respecting all the constraints.


Author(s):  
Mahesh Kumar ◽  
Perumal Nallagownden ◽  
Irraivan Elamvazuthi ◽  
Pandian Vasant ◽  
Luqman Hakim Rahman

In the distribution system, distributed generation (DG) are getting more important because of the electricity demands, fossil fuel depletion and environment concerns. The placement and sizing of DGs have greatly impact on the voltage stability and losses in the distribution network. In this chapter, a particle swarm optimization (PSO) algorithm has been proposed for optimal placement and sizing of DG to improve voltage stability index in the radial distribution system. The two i.e. active power and combination of active and reactive power types of DGs are proposed to realize the effect of DG integration. A specific analysis has been applied on IEEE 33 bus system radial distribution networks using MATLAB 2015a software.