An Investigation of Heat Transfer in a Film Cooled Transonic Turbine Cascade: Part I — Steady Heat Transfer

Author(s):  
D. E. Smith ◽  
J. V. Bubb ◽  
O. Popp ◽  
H. Grabowski ◽  
T. E. Diller ◽  
...  

Experiments were performed in a transonic cascade wind tunnel to investigate the film effectiveness and heat transfer coefficient on the suction side of a high-turning turbine rotor blade. The coolant scheme consisted of six rows of staggered, discrete cooling holes on and near the leading edge of the blade in a showerhead configuration. Air was cooled in order to match the density ratios found under engine conditions. Six high-frequency heat flux gauges were installed downstream of the cooling holes on the suction side of the blade. Experiments were performed with and without film and the coolant to freestream total pressure ratio was varied from 1.02 to 1.19. In order to simulate real engine flow conditions, the exit Mach number was set to 1.2 and the exit Reynolds number was set to 5×106. The freestream turbulence was approximately 1%. The heat transfer coefficient was found to increase with the addition of film cooling an average of 14% overall and to a maximum of 26% at the first gauge location. The average film cooling effectiveness over the gauge locations was 25%. Both the heat transfer coefficient and the film cooling effectiveness were found to have only a weak dependence upon the coolant to freestream total pressure ratio at the gauge locations used in this study.

Author(s):  
Rui-dong Wang ◽  
Cun-liang Liu ◽  
Hai-yong Liu ◽  
Hui-ren Zhu ◽  
Qi-ling Guo ◽  
...  

Heat transfer of the counter-inclined cylindrical and laid-back holes with and without impingement on the turbine vane leading edge model are investigated in this paper. To obtain the film cooling effectiveness and heat transfer coefficient, transient temperature measurement technique on complete surface based on double thermochromic liquid crystals is used in this research. A semi-cylinder model is used to model the vane leading edge which is arranged with two rows of holes. Four test models are measured under four blowing ratios including cylindrical film holes with and without impingement tube structure, laid-back film holes with and without impingement tube structure. This is the second part of a two-part paper, the first part paper GT2018-76061 focuses on film cooling effectiveness and this study will focus on heat transfer. Contours of surface heat transfer coefficient and laterally averaged result are presented in this paper. The result shows that the heat transfer coefficient on the surface of the leading edge is enhanced with the increase of blowing ratio for same structure. The shape of the high heat transfer coefficient region gradually inclines to span-wise direction as the blowing ratio increases. Heat transfer coefficient in the region where the jet core flows through is relatively lower, while in the jet edge region the heat transfer coefficient is relatively higher. Compared with cylindrical hole, laid-back holes give higher heat transfer coefficient. Meanwhile, the introduction of impingement also makes heat transfer coefficient higher compared with cross flow air intake. It is found that the heat transfer of the combination of laid-back hole and impingement tube can be very high under large blowing ratio which should get attention in the design process.


2012 ◽  
Vol 134 (5) ◽  
Author(s):  
Akira Murata ◽  
Satomi Nishida ◽  
Hiroshi Saito ◽  
Kaoru Iwamoto ◽  
Yoji Okita ◽  
...  

Cooling at the trailing edge of a gas turbine airfoil is one of the most difficult problems because of its thin shape, high thermal load from both surfaces, hard-to-cool geometry of narrow passages, and at the same time demand for structural strength. In this study, the heat transfer coefficient and film cooling effectiveness on the pressure-side cutback surface was measured by a transient infrared thermography method. Four different cutback geometries were examined: two smooth cutback surfaces with constant-width and converging lands (base and diffuser cases) and two roughened cutback surfaces with transverse ribs and spherical dimples. The Reynolds number of the main flow defined by the mean velocity and two times the channel height was 20,000, and the blowing ratio was varied among 0.5, 1.0, 1.5, and 2.0. The experimental results clearly showed spatial variation of the heat transfer coefficient and the film cooling effectiveness on the cutback and land top surfaces. The cutback surface results clearly showed periodically enhanced heat transfer due to the periodical surface geometry of ribs and dimples. Generally, the increase of the blowing ratio increased both the heat transfer coefficient and the film cooling effectiveness. Within the present experimental range, the dimple surface was a favorable cutback-surface geometry because it gave the enhanced heat transfer without deterioration of the high film cooling effectiveness.


Author(s):  
Huitao Yang ◽  
Hamn-Ching Chen ◽  
Je-Chin Han ◽  
Hee-Koo Moon

Numerical simulations were performed to predict the film cooling effectiveness and the associated heat transfer coefficient on the leading edge of a rotating blade in a 1-1/2 turbine stage using a Reynolds stress turbulence model together with a non-equilibrium wall function. Simulations were performed for both the design and off-design conditions to investigate the effects of blade rotation on the leading edge film cooling effectiveness and heat transfer coefficient distributions. It was found that the tilt stagnation line on the leading edge of rotor moves from the pressure side to the suction side, and the instantaneous coolant streamlines shift from the suction side to the pressure side with increasing rotating speed. This trend was supported by the experimental results. The result also showed that the heat transfer coefficient increases, but film cooling effectiveness decreases with increasing rotating speed. In addition, the unsteady characteristics of the film cooling and heat transfer at different time phases, as well as different rotating speeds, were also reported.


Author(s):  
Jin Young Jeong ◽  
Woobin Kim ◽  
Jae Su Kwak ◽  
Jung Shin Park

Leakage flow between the rotating turbine blade tip and the fixed casing causes high heat loads and thermal stress on the tip and near the tip region. For this study, new squealer tips called partial cavity tips, which combine the advantages of plane and squealer tips, were suggested, and the effects of the cavity shape on the tip heat transfer coefficient and film cooling effectiveness were investigated experimentally in a low speed linear cascade. The suggested blade tips had a flat surface near the leading edge and a squealer cavity from the mid-chord to trailing edge region to achieve the advantages of both blade tip types. The heat transfer coefficient was measured via the 1-D transient heat transfer technique using an IR camera, and the film cooling effectiveness was obtained via the pressure sensitive paint (PSP) technique. Results showed that the heat transfer coefficient and film cooling effectiveness on the partial cavity tips strongly depended on the cavity shape. Near the leading edge, the heat transfer coefficients for the partial cavity tip cases were lower than that for the squealer tip case. However, the heat transfer coefficient on the cavity surface was higher for the partial cavity tip cases. The D10 tip showed a similar distribution of film cooling effectiveness to that of the PLN tip near the leading edge and the DSS tip near the mid-chord region. However, the overall averaged film cooling effectiveness of the DSS tip was higher than that of the D10 tip.


2021 ◽  
pp. 1-28
Author(s):  
Fan Zhang ◽  
Cun Liang Liu ◽  
Lin Ye ◽  
Bingran Li ◽  
Shuaiqi Zhang

Abstract This research experimentally investigated the net benefit of film cooling with 6 rows of impingement-effusion structures on the suction surface of a vane. The experiment obtained the film cooling effectiveness of double-walled system on the suction surface via the pressure-sensitive paint (PSP) technique. The film cooling effectiveness obtained by the PSP technique is coupled with the transient liquid crystal (TLC) technique to determine the heat transfer coefficient. This combination of techniques reduces the time required for the experiment and improves the efficiency of the experiment. Through the experimentally measured film cooling effectiveness and dimensionless heat transfer coefficient, the net heat flux reduction (NHFR) is calculated to comprehensively measure the net benefit of film cooling. At the same time, in view of the lower net benefit of film cooling of the film holes in the front of the suction surface under higher mass flux ratio, the study improved the cylindrical holes into fan-shaped holes, and proposed two improvement schemes: Vane A and Vane B. The findings show that using the coupling of PSP and TLC to determine the heat transfer coefficient can yield credible results. The improvement of the fan-shaped holes makes the film cooling effectiveness and heat transfer coefficient ratio improved compared with the baseline vane. Changing cylindrical holes to fan-shaped holes does not necessarily lead to better net benefit of film cooling. The fan-shaped holes should be arranged reasonably to obtain better net benefit of film cooling.


Author(s):  
Fan Zhang ◽  
Cunliang Liu ◽  
Shuaiqi Zhang ◽  
Lin Ye ◽  
Bingran Li

Abstract To study the film cooling performance of impingement-effusion structures, it is important to study their adiabatic film cooling effectiveness. To improve the adiabatic film cooling effectiveness on a vane, some rows of cylindrical effusion holes are changed into fan-shaped holes. This experiment measured the adiabatic film cooling effectiveness of the double-walled system on the suction surface via the pressure-sensitive paint (PSP) technique. The film cooling effectiveness obtained by the PSP technique is coupled with the transient liquid crystal (TLC) technique to determine the heat transfer coefficient. This combination of techniques reduces the time required for the experiment and improves the efficiency of the experiment. The heat transfer coefficient ratio is used to evaluate the level of heating transfer. The net heat flux reduction (NHFR) is used to quantify the net benefit of film cooling. Two experimental vanes’ (A and B) film holes are both arranged in 6 rows of holes. There are 15 holes in each row. Only the positions of the fan-shaped holes are different. The experimental conditions include the mainstream Reynolds number (Re = 151,000) based on the chord length and inlet velocity, the turbulence intensities (Tu = 0.77%, 16.9%), and the mass flux ratios (ṁc/ṁg = 0.4%, 0.8%, 1.6%). The findings show that when the mass flux ratio increases to a point, the film cooling effectiveness does not improve. Increasing the turbulence intensity leads to a decrease in the film cooling effectiveness except for the region after Row 6 on Vane B. Using the coupling of PSP and TLC to determine the heat transfer coefficient can yield credible results. The turbulence intensity and the arrangement of the film holes have obvious effects on the distribution of the heat transfer coefficient ratio. The effects of turbulence intensity, mass flux ratio and hole arrangement on NHFR were studied.


Author(s):  
Dennis Brauckmann ◽  
Jens von Wolfersdorf

The measurement of adiabatic film cooling effectiveness data and heat transfer coefficient data for a row of fanshaped film cooling holes at different compound angles is presented in this paper. The measurements are performed at engine-like temperature ratios in a hot gas test facility on a flat test plate. For the film cooling geometry, a row of five laidback-fanshaped holes was used. The temperature distribution on the flat plate is measured using infrared-thermography (IR). Steady state measurements are used to obtain the film cooling effectiveness. For the determination of the heat transfer coefficient ratio with and without film cooling on the test plate, a transient measurement technique is applied. Results for both the adiabatic film cooling effectiveness and the heat transfer coefficient ratio are given. The influence of different blowing ratios on the injection with compound angles of 0°, 30° and 45° will be discussed. From this study, the increasing compound angle showed only small effects on the pitch-wise lateral averaged adiabatic film cooling effectiveness but increased the heat transfer on the film cooled flat plate with coolant injection.


2010 ◽  
Vol 133 (1) ◽  
Author(s):  
Cun-liang Liu ◽  
Hui-ren Zhu ◽  
Jiang-tao Bai ◽  
Du-chun Xu

Film cooling performances of two kinds of converging-slot-hole (console) with different exit-entry area ratios have been measured using a new transient liquid crystal measurement technique, which can process the nonuniform initial wall temperature. Four momentum ratios are tested. The film cooling effectiveness distribution features are similar for the two consoles under all the momentum ratios. Consoles with smaller exit-entry area ratio produce higher cooling effectiveness. And the laterally averaged cooling effectiveness results show that the best momentum ratio for both consoles’ film cooling effectiveness distribution is around 2. For both consoles, the heat transfer in the midspan region is stronger than that in the hole centerline region in the upstream but gradually becomes weaker as flowing downstream. With the momentum ratio increasing, the normalized heat transfer coefficient h∕h0 of both consoles increases. In the upstream, the heat transfer coefficient of console with small exit-entry area ratio is higher. But in the downstream, the jets’ turbulence and the couple vortices play notable elevating effect on the heat transfer coefficient for large exit-entry area ratio case, especially under small momentum ratios. Consoles with smaller exit-entry area ratio provide better thermal protection because of higher cooling effectiveness. And the distributions of heat flux ratio are similar with those of cooling effectiveness because the influence of η on q∕q0 is larger. For the consoles, smaller exit-entry area ratios produce lower discharge coefficients when the pressure variation caused by the hole shape is regarded as flow resistance.


2019 ◽  
Vol 141 (7) ◽  
Author(s):  
Jin Young Jeong ◽  
Woobin Kim ◽  
Jae Su Kwak ◽  
Jung Shin Park

Leakage flow between the rotating turbine blade tip and the fixed casing causes high heat loads and thermal stress on the tip and near the tip region. For this study, new squealer tips called partial cavity tips, which combine the advantages of plane and squealer tips, were suggested, and the effects of the cavity shape on the tip heat transfer coefficient and film cooling effectiveness were investigated experimentally in a low-speed linear cascade. The suggested blade tips had a flat surface near the leading edge and a squealer cavity from the mid-chord to trailing edge region to achieve the advantages of both blade tip types. The heat transfer coefficient was measured via the 1-D transient heat transfer technique using an IR camera, and the film cooling effectiveness was obtained via the pressure-sensitive paint (PSP) technique. Results showed that the heat transfer coefficient and film cooling effectiveness on the partial cavity tips strongly depended on the cavity shape. Near the leading edge, the heat transfer coefficients for the partial cavity tip cases were lower than that for the squealer tip case. However, the heat transfer coefficient on the cavity surface was higher for the partial cavity tip cases. The D10 tip showed a similar distribution of film cooling effectiveness to that of the plane (PLN) tip near the leading edge and the double side squealer (DSS) tip near the mid-chord region. However, the overall average film cooling effectiveness of the DSS tip was higher than that of the D10 tip.


1974 ◽  
Vol 96 (2) ◽  
pp. 239-245 ◽  
Author(s):  
V. L. Eriksen ◽  
R. J. Goldstein

Film cooling effectiveness and heat transfer are measured downstream of injection through discrete holes into a turbulent mainstream boundary layer. Air is injected through both a single hole and a row of holes spaced at three-diameter intervals and inclined at an angle of 35 deg to the main flow. There is little difference between the heat transfer coefficient with blowing and without blowing at low blowing rates (mass flux ratios). In fact, at low blowing rates, injection is found to decrease somewhat the heat transfer coefficient from that measured without blowing. As the mass flux ratio increases past unity, the heat transfer coefficient increases especially with injection through a row of holes. The peak heat transfer is usually found at the edge of the spreading jets (i.e., between two holes). At a blowing rate near two, the lateral average of the heat transfer is as much as 27 percent higher than the heat transfer with no blowing. The increase in heat transfer is attributed to the interaction between the jets and the free stream, causing high levels of turbulence.


Sign in / Sign up

Export Citation Format

Share Document