A comparative light and electron microscopic study of microspore and tapetal development in male fertile and cytoplasmic male sterile oilseed rape (Brassica napus)

1986 ◽  
Vol 64 (5) ◽  
pp. 1055-1068 ◽  
Author(s):  
I. Grant ◽  
W. D. Beversdorf ◽  
R. L. Peterson

The cytological development of male cells and the tapetum of male fertile and combined cytoplasmic triazine-resistant cyto-plasmic-genetic male sterile (ctr) lines of B. napus L. was studied using light, scanning electron, and transmission electron microscopy. Development of the cytoplasmic-genetic male sterile anther was similar to the normal anther up to and including meiotic prophase I. After this stage, degeneration of the microspore mother cells occurs within the callose walls, and tetrads of microspores are not formed. These degenerating microspore mother cells appear to develop numerous endoplasmic reticulum derived vesiculated structures, which may be involved in lysis of organelles. Degeneration occurs simultaneously with a proliferation of the tapetum, which eventually fills the anther locule. It is not clear whether the abortion of the microspore mother cells during meiosis stimulates proliferation of the tapetum or whether the proliferating tapetum actually interferes with microspore development thereby causing degeneration. Dilated endoplasmic reticulum cisternae containing crystalline-like deposits, and plastids with osmiophilic bodies, are frequent in cells of the proliferated tapetum of cytoplasmic-genetic male sterile anthers.

Author(s):  
Peter M. Andrews

Scanning electron microscopy, supplemented with light microscopy and transmission electron microscopy, was used to study aminonucleoside nephrosis in rats. Aminonucleoside nephrosis was induced by daily injections of puromycin aminonucIeoside (1.5 mg/10 gm). When the rats exhibited considerable proteinuria (10 mg/ml after 14 days of injections), their kidneys were fixed by vascular perfusion, sectioned and critical point dried.


1984 ◽  
Vol 39 (7-8) ◽  
pp. 776-780
Author(s):  
T. K. Mandal ◽  
S. N. Chatterjee

Abstract Polymyxin B produced dose dependent changes in the surface topography of the goat erythrocyte cells. Transformation from the normal biconcave discs through crenated structures to the final rounded or spherical shape was recorded by scanning electron microscopy. A maxim um of three to four crenations per cell was recorded corresponding to a polymyxin dose of 15.62 ng/ml. Transmission electron microscopy of the ultrathin sections of treated or untreated erythrocytes indicated that the crenations were formed by protrusions of the plasma membrane, occurring presumably because of the local increase of membrane fluidity after polymyxin treatment. Changes in the shape of the erythrocytes to the ultimate rounded forms were also indicated by the transmission electron microscopy.


Author(s):  
Nakazo Watari ◽  
Yasuaki Hotta ◽  
Yoshio Mabuchi

It is very useful if we can observe the identical cell elements within the same sections by light microscopy (LM), transmission electron microscopy (TEM) and/or scanning electron microscopy (SEM) sequentially, because, the cell fine structure can not be indicated by LM, while the color is; on the other hand, the cell fine structure can be very easily observed by EM, although its color properties may not. However, there is one problem in that LM requires thick sections of over 1 μm, while EM needs very thin sections of under 100 nm. Recently, we have developed a new method to observe the same cell elements within the same plastic sections using both light and transmission (conventional or high-voltage) electron microscopes.In this paper, we have developed two new observation methods for the identical cell elements within the same sections, both plastic-embedded and paraffin-embedded, using light microscopy, transmission electron microscopy and/or scanning electron microscopy (Fig. 1).


Author(s):  
Loren Anderson ◽  
Pat Pizzo ◽  
Glen Haydon

Transmission electron microscopy of replicas has long been used to study the fracture surfaces of components which fail in service. Recently, the scanning electron microscope (SEM) has gained popularity because it allows direct examination of the fracture surface. However, the somewhat lower resolution of the SEM coupled with a restriction on the sample size has served to limit the use of this instrument in investigating in-service failures. It is the intent of this paper to show that scanning electron microscopic examination of conventional negative replicas can be a convenient and reliable technique for determining mode of failure.


Author(s):  
A.J. Tousimis ◽  
T.R. Padden

The size, shape and surface morphology of human erythrocytes (RBC) were examined by scanning electron microscopy (SEM), of the fixed material directly and by transmission electron microscopy (TEM) of surface replicas to compare the relative merits of these two observational procedures for this type specimen.A sample of human blood was fixed in glutaraldehyde and washed in distilled water by centrifugation. The washed RBC's were spread on freshly cleaved mica and on aluminum coated microscope slides and then air dried at room temperature. The SEM specimens were rotary coated with 150Å of 60:40- gold:palladium alloy in a vacuum evaporator using a new combination spinning and tilting device. The TEM specimens were preshadowed with platinum and then rotary coated with carbon in the same device. After stripping the RBC-Pt-C composite film, the RBC's were dissolved in 2.5N HNO3 followed by 0.2N NaOH leaving the preshadowed surface replicas showing positive topography.


Author(s):  
J. C. Russ ◽  
E. McNatt

In order to study the retention of copper in cirrhotic liver, rats were made cirrhotic by carbon tetrachloride inhalation twice weekly for three months and fed 0.2% copper acetate ad libidum in drinking water for one month. The liver tissue was fixed in osmium, sectioned approximately 2000 Å thick, and stained with lead citrate. The section was examined in a scanning electron microscope (JEOLCO JSM-2) in the transmission electron mode.Figure 1 shows a typical area that includes a red blood cell in a sinusoid, a disse, and a portion of the cytoplasm of a hepatocyte which contains several mitochondria, peribiliary dense bodies, glycogen granules, and endoplasmic reticulum.


Author(s):  
Venita F. Allison ◽  
J. E. Ubelaker ◽  
J. H. Martin

It has been suggested that parasitism results in a reduction of sensory structures which concomitantly reflects a reduction in the complexity of the nervous system. The present study tests this hypothesis by examining the fine morphology and the distribution of sensory receptors for two species of aspidogastrid trematodes by transmission and scanning electron microscopy. The species chosen are an ectoparasite, Cotylaspis insignis and an endoparasite, Aspidogaster conchicola.Aspidogaster conchicola and Cotylaspis insignis were obtained from natural infections of clams, Anodonta corpulenta and Proptera purpurata. The specimens were fixed for transmission electron microscopy in phosphate buffered paraformaldehyde followed by osmic acid in the same buffer, dehydrated in an ascending series of ethanol solutions and embedded in Epon 812.


Author(s):  
Thomas P. Turnbull ◽  
W. F. Bowers

Until recently the prime purposes of filters have been to produce clear filtrates or to collect particles from solution and then remove the filter medium and examine the particles by transmission electron microscopy. These filters have not had the best characteristics for scanning electron microscopy due to the size of the pores or the surface topography. Advances in polymer chemistry and membrane technology resulted in membranes whose characteristics make them versatile substrates for many scanning electron microscope applications. These polysulphone type membranes are anisotropic, consisting of a very thin (0.1 to 1.5 μm) dense skin of extremely fine, controlled pore texture upon a much thicker (50 to 250μm), spongy layer of the same polymer. Apparent pore diameters can be controlled in the range of 10 to 40 A. The high flow ultrafilters which we are describing have a surface porosity in the range of 15 to 25 angstrom units (0.0015-0.0025μm).


Sign in / Sign up

Export Citation Format

Share Document