scholarly journals CFD Analysis of the Passive Decay Heat Removal System of an LBE-Cooled Fast Reactor

2018 ◽  
Vol 2018 ◽  
pp. 1-11
Author(s):  
Jiarun Mao ◽  
Lei Song ◽  
Yuhao Liu ◽  
Jiming Lin ◽  
Shanfang Huang ◽  
...  

This paper presents capacity of the passive decay heat removal system (DHRS) operated under the natural circulation conditions to remove decay heat inside the main vessel of the Lead-bismuth eutectic cooled Fast Reactor (LFR). The motivation of this research is to improve the inherent safety of the LFR based on the China Accelerator Driven System (ADS) engineering project. Usually the plant is damaged due to the failure of the main pumps and the main heat exchangers under the Station Blackout (SBO). To prevent this accident, we proposed the DHRS based on the diathermic oil cooling for the LFR. The behavior of the DHRS and the plant was simulated using the CFD code STAR CCM+ using LFR with DHRS. The purpose of this analysis is to evaluate the heat exchange capacity of the DHRS and is to provide the reference for structural improvement and experimental design. The results show that the stable natural circulations are established in both the main vessel and the DHRS. During the decay process, the heat exchange power is above the core decay heat power. In addition, in-core decay heat and heat storage inside the main vessel are efficiently removed. All the thermal-hydraulics parameters are within a safe range. Moreover, the highest temperature occurs at the upper surface of the core. A swirl occurs at the corner of the lateral core surface and some improvements should be considered. And the natural circulation driving force can be further increased by reducing the loop resistance or increasing the natural circulation height based on the present design scenario to enhance the heat exchange effect.

2015 ◽  
Vol 52 (9) ◽  
pp. 1102-1121 ◽  
Author(s):  
Osamu Watanabe ◽  
Kazuhiro Oyama ◽  
Junji Endo ◽  
Norihiro Doda ◽  
Ayako Ono ◽  
...  

2016 ◽  
Vol 53 (9) ◽  
pp. 1385-1396 ◽  
Author(s):  
Ayako Ono ◽  
Hideki Kamide ◽  
Jun Kobayashi ◽  
Norihiro Doda ◽  
Osamu Watanabe

Author(s):  
Seong Kuk Cho ◽  
Jekyoung Lee ◽  
Jeong Ik Lee ◽  
Jae Eun Cha

A Sodium-cooled Fast Reactor (SFR) has receiving attention as one of the promising next generation nuclear reactors because it can recycle the spent nuclear fuel produced from the current commercial nuclear reactors and accomplish higher thermal efficiency than the current commercial nuclear reactors. However, after shutdown of the nuclear reactor core, the accumulated fission products of the SFR also decay and release heat via radiation within the reactor. To remove this residual heat, a decay heat removal system (DHRS) with supercritical CO2 (S-CO2) as the working fluid is suggested with a turbocharger system which achieves passive operational capability. However, for designing this system an improved S-CO2 turbine design methodology should be suggested because the existing methodology for designing the S-CO2 Brayton cycle has focused only on the compressor design near the critical point. To develop a S-CO2 turbine design methodology, the non-dimensional number based design and the 1D mean line design method were modified and suggested. The design methodology was implemented into the developed code and the code results were compared with existing turbine experimental data. The data were collected under air and S-CO2 environment. The developed code in this research showed a reasonable agreement with the experimental data. Finally using the design code, the turbocharger design for the suggested DHRS and prediction of the off design performance were carried out. As further works, more effort will be put it to expand the S-CO2 turbine test data for validating the design code and methodology.


Author(s):  
Andrea Bersano ◽  
Mario De Salve ◽  
Cristina Bertani ◽  
Nicolò Falcone ◽  
Bruno Panella

Within the field of research and development of innovative nuclear reactors, in particular Generation IV reactors and Small Modular Reactors (SMR), the design and the improvement of safety systems play a crucial role. Among all the safety systems high attention is dedicated to passive systems that do not need external energy to operate, with a very high reliability also in the case of station blackout, and which are largely used in evolutionary technology reactors. The aim of this work is the experimental and numerical analysis of a passive system that operates in natural circulation in order to study the mechanism and the efficiency of heat removal. The final goal is the development of a methodology that can be used to study this class of systems and to assess the thermal-hydraulic code RELAP5 for these specific applications. Starting from a commercial size system, which is the decay heat removal system of the experimental lead cooled reactor ALFRED, an experimental facility has been designed, built and tested with the aim of studying natural circulation in passive systems for nuclear applications. The facility has been simulated and optimized using the thermal-hydraulic code RELAP5-3D. During the experimental tests, temperatures and pressures are measured and the experimental results are compared with the ones predicted by the code. The results show that the system operates effectively, removing the given thermal power. The code can predict well the experimental results but high attention must be dedicated to the modeling of components where non-condensable gases are present (condenser pool and surrounding ambient). This facility will be also used to validate the scaling laws among systems that operate in natural circulation.


Author(s):  
H. Qian ◽  
Z. Li ◽  
L. Ren

A passive decay heat removal system (DHRS) has been installed on Chinese Experimental Fast Reactor (CEFR). To well predict the thermal-hydraulics behavior of DHRS in transient, an integrated model has been developed for CEFR by using OASIS code. The model included the main thermal transfer system and DHRS circuit. The transient analysis of loss of off-site power (LOSP) accident with various initial steady states has been performed. The calculation results show that the initial steady state does not essentially effect on the peak cladding temperature in the core.


2021 ◽  
Vol 236 ◽  
pp. 01018
Author(s):  
Chongju Hu ◽  
Wangli Huang ◽  
Zhizhong Jiang ◽  
Qunying Huang ◽  
Yunqing Bai ◽  
...  

.A lead-based reactor with employing heat pipes as passive residual heat removal system (PRHRS) for longterm decay heat removal was designed. Three-dimensional computational fluid dynamics (CFD) software FLUENT was adopted to simulate the thermal-hydraulic characteristics of the PRHRS under Station-Black-Out (SBO) accident condition. The results showed that heat in the core could be removed smoothly by the PRHRS, and the core temperature difference is less than 20 K.


Sign in / Sign up

Export Citation Format

Share Document